Volume determinations using computed tomography.

Computed tomography potentially offers the most accurate noninvasive means of estimating in vivo volumes. Contiguous 1-cm-thick CT scans were obtained through phantoms, dog kidneys in vivo, and human spleens before splenectomy. Cross-sectional areas were calculated for each individual scan and volumes then determined with each of four mathematical integration techniques. Volume estimations were compared to volumes determined by water displacement. The simplest, most practical means of calculating volumes, using the summation-of-areas technique with scans obtained at 2 cm intervals, was similar in accuracy to more complex methods. The mean percentage error of volume calculations using the sum-of-areas technique was 4.95% for five immobile phantoms, 3.86% for eight dog kidneys, 3.59% for eight human spleens in vivo at 1 cm scan spacing, and 3.65% for the same human spleens at 2 cm scan spacings. Difficulties in visual recognition and manual tracking of object boundaries seem to be more significant sources of error than patient-related factors.

[1]  L. Kuhns,et al.  Variation of Position of the Kidneys and Diaphragm in Patients Undergoing Repeated Suspension of Respiration , 1979, Journal of computer assisted tomography.

[2]  P. Hoffer,et al.  Splenic mobility and its effect on estimates of splenic mass. , 1975, Radiology.

[3]  R. Brown,et al.  Splenic size and function in adult coeliac disease. , 1980, The British journal of radiology.

[4]  T. Koga,et al.  Correlation between sectional area of the spleen by ultrasonic tomography and actual volume of the removed spleen , 1979, Journal of clinical ultrasound : JCU.

[5]  S. Larson,et al.  Dimensions of the normal adult spleen scan and prediction of spleen weight. , 1971, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  S. Heymsfield,et al.  Accurate measurement of liver, kidney, and spleen volume and mass by computerized axial tomography. , 1979, Annals of internal medicine.

[7]  P. Costello,et al.  Assessment of tumor response by computed tomography liver volumetry. , 1983, The Journal of computed tomography.

[8]  T. Jernigan,et al.  Semiautomated methods for quantitating CSF volume on cranial computed tomography. , 1979, Radiology.

[9]  H. Holm,et al.  Spleen volume determination by ultrasonic scanning. , 2009, Scandinavian journal of haematology.

[10]  G. B. Hopkins,et al.  Measurement of liver volume by emission computed tomography. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  L. Blendis,et al.  Radiological determination of spleen size. , 1969, Gut.

[12]  R. P. Spencer DETERMINATION OF ORGAN VOLUMES BY SCINTILLATION SCANNING. , 1964, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  C. Maynard,et al.  A computer approach to the prediction of spleen weight from routine films. , 1966, Radiology.