A novel quasi-oppositional harmony search algorithm and fuzzy logic controller for frequency stabilization of an isolated hybrid power system

Abstract The intermittent wind power in isolated hybrid distributed generation (IHDG) may cause serious problems associated with frequency (f) and power (P) fluctuation. Energy storage devices such as battery, super capacitor, and superconducting magnetic energy storage (SMES) may be used to reduce these fluctuations associated with f and P. This paper presents a study of IHDG power system for improving both f and P deviation profiles with the help of SMES. The studied IHDG power system is consisted of wind turbine generator and diesel engine generator. Both f and P control problems of the studied power system model are addressed in presence or absence of SMES. Fuzzy logic based proportional–integral–derivative (PID) controller with SMES is used for the purpose of minimization of f and P deviations. The different tunable parameters of the PID controller and those of the SMES are tuned by a novel quasi-oppositional harmony search algorithm. Performance study of the IHDG power system model is carried out under different perturbation conditions. The results demonstrate minimum f and P deviations may be achieved by using the proposed fuzzy logic based PID controller along with SMES.

[1]  K. Lee,et al.  A new meta-heuristic algorithm for continuous engineering optimization: harmony search theory and practice , 2005 .

[2]  Cuk Supriyadi Ali Nandar,et al.  Robust PI control of smart controllable load for frequency stabilization of microgrid power system , 2013 .

[3]  Lotfi A. Zadeh,et al.  Fuzzy Sets , 1996, Inf. Control..

[4]  Li Wang,et al.  Small-Signal Stability Analysis of an Autonomous Hybrid Renewable Energy Power Generation/Energy Storage System Part I: Time-Domain Simulations , 2008, IEEE Transactions on Energy Conversion.

[5]  Tore Undeland,et al.  Voltage and Frequency Control in Offshore Wind Turbines Connected to Isolated Oil Platform Power Systems , 2012 .

[6]  Rahula A. Attalage,et al.  A hybrid tool to combine multi-objective optimization and multi-criterion decision making in designing standalone hybrid energy systems , 2013 .

[7]  Haiping Ma,et al.  Oppositional ant colony optimization algorithm and its application to fault monitoring , 2010, Proceedings of the 29th Chinese Control Conference.

[8]  Sakti Prasad Ghoshal,et al.  INTELLIGENT PARTICLE SWARM OPTIMIZED FUZZY PID CONTROLLER FOR AVR SYSTEM , 2007 .

[9]  J. Clare,et al.  Wind–Diesel Generation Using Doubly Fed Induction Machines , 2008, IEEE Transactions on Energy Conversion.

[10]  S. C. Tripathy,et al.  Dynamics and stability of wind and diesel turbine generators with superconducting magnetic energy storage unit on an isolated power system , 1991 .

[11]  Francesco Castelli-Dezza,et al.  Control strategies and configurations of hybrid distributed generation systems , 2012 .

[12]  Zong Woo Geem,et al.  A New Heuristic Optimization Algorithm: Harmony Search , 2001, Simul..

[13]  Wei Liu,et al.  Multi-stage underfrequency load shedding for islanded microgrid with equivalent inertia constant analysis , 2013 .

[14]  Sakti Prasad Ghoshal,et al.  A novel opposition-based gravitational search algorithm for combined economic and emission dispatch problems of power systems , 2012 .

[15]  Hassan Bevrani,et al.  Multiobjective design of load frequency control using genetic algorithms , 2012 .

[16]  D. P. Kothari,et al.  Dynamics of diesel and wind turbine generators on an isolated power system , 1999 .

[17]  Mahamed G. H. Omran,et al.  Global-best harmony search , 2008, Appl. Math. Comput..

[18]  Yaodong Wang,et al.  Modelling and simulation of a distributed power generation system with energy storage to meet dynamic household electricity demand , 2013 .

[19]  T. Funabashi,et al.  Generating power leveling of renewable energy for small power system in isolated island , 2005, Proceedings of the 13th International Conference on, Intelligent Systems Application to Power Systems.

[20]  Abhik Banerjee,et al.  Modeling and seeker optimization based simulation for intelligent reactive power control of an isolated hybrid power system , 2013, Swarm Evol. Comput..

[21]  Sakti Prasad Ghoshal,et al.  An opposition-based harmony search algorithm for engineering optimization problems , 2014 .

[22]  N. K. Bansal,et al.  Load frequency control of isolated wind diesel hybrid power systems , 1997 .

[23]  R. Billinton,et al.  Evaluation of different operating strategies in small stand-alone power systems , 2005, IEEE Transactions on Energy Conversion.

[24]  S. C. Tripathy Dynamic simulation of hybrid wind-diesel power generation system with superconducting magnetic energy storage , 1997 .

[25]  Z Kong,et al.  On an adaptive harmony search algorithm , 2009 .

[26]  H. J. Boenig,et al.  Commissioning Tests of the Bonneville Power Administration 30 MJ Superconducting Magnetic Energy Storage Unit , 1985, IEEE Power Engineering Review.

[27]  S. C. Tripathy,et al.  Dynamics and stability of a wind stand-alone power system , 1993 .

[28]  Sakti Prasad Ghoshal,et al.  Comparative seeker and bio-inspired fuzzy logic controllers for power system stabilizers , 2011 .

[29]  N. K. Bansal,et al.  Dynamics and control of isolated wind‐diesel power systems , 1995 .

[30]  Hamid R. Tizhoosh,et al.  Opposition-Based Learning: A New Scheme for Machine Intelligence , 2005, International Conference on Computational Intelligence for Modelling, Control and Automation and International Conference on Intelligent Agents, Web Technologies and Internet Commerce (CIMCA-IAWTIC'06).

[31]  P. K. Chattopadhyay,et al.  Solution of Economic Power Dispatch Problems Using Oppositional Biogeography-based Optimization , 2010 .

[32]  Caisheng Wang,et al.  Power Management of a Stand-Alone Wind/Photovoltaic/Fuel Cell Energy System , 2008, IEEE Transactions on Energy Conversion.

[33]  T. Funabashi,et al.  Oscillation frequency control based on H/sub /spl infin// controller for a small power system using renewable energy facilities in isolated island , 2006, 2006 IEEE Power Engineering Society General Meeting.

[34]  R. Boom,et al.  Superconductive energy storage for power systems , 1972 .

[35]  Xiaolei Wang,et al.  UNI-MODAL AND MULTI-MODAL OPTIMIZATION USING MODIFIED HARMONY SEARCH METHODS , 2009 .

[36]  Kashem M. Muttaqi,et al.  An integrated control approach for standalone operation of a hybridised wind turbine generating system with maximum power extraction capability , 2013 .

[37]  Zong Woo Geem,et al.  Recent Advances in Harmony Search , 2008 .

[38]  Issarachai Ngamroo,et al.  Robust Frequency Control of Wind-Diesel Hybrid Power System Using Superconducting Magnetic Energy Storage , 2009 .

[39]  S. C. Tripathy,et al.  Stability simulation and parameter optimization of a hybrid wind-diesel power generation system , 1992 .

[40]  Jing J. Liang,et al.  A self-adaptive global best harmony search algorithm for continuous optimization problems , 2010, Appl. Math. Comput..

[41]  Sakti Prasad Ghoshal,et al.  Solution of combined economic and emission dispatch problems of power systems by an opposition-based harmony search algorithm , 2012 .

[42]  Z. Geem Music-Inspired Harmony Search Algorithm: Theory and Applications , 2009 .

[43]  Sakti Prasad Ghoshal,et al.  Load frequency stabilization by coordinated control of Thyristor Controlled Phase Shifters and superconducting magnetic energy storage for three types of interconnected two-area power systems , 2010 .

[44]  Issarachai Ngamroo,et al.  Robust coordinated control of electrolyzer and PSS for stabilization of microgrid based on PID-based mixed H2/H∞ control , 2012 .

[45]  Li Wang,et al.  Analysis of a novel autonomous marine hybrid power generation/energy storage system with a high-voltage direct current link , 2008 .

[46]  Rahmat-Allah Hooshmand,et al.  Optimal design of adaptive under frequency load shedding using artificial neural networks in isolated power system , 2012 .

[47]  Nand Kishor,et al.  Robust H-infinity load frequency control in hybrid distributed generation system , 2013 .

[48]  M. Fesanghary,et al.  An improved harmony search algorithm for solving optimization problems , 2007, Appl. Math. Comput..

[49]  Quanmin Zhu,et al.  Decentralised load-frequency controller design based on structured singular values , 1998 .

[50]  G. Joos,et al.  Comparison of Energy Storage System Technologies and Configurations in a Wind Farm , 2007, 2007 IEEE Power Electronics Specialists Conference.

[51]  Zong Woo Geem,et al.  Optimal Scheduling of Multiple Dam System Using Harmony Search Algorithm , 2007, IWANN.

[52]  T. Funabashi,et al.  A hybrid power system using alternative energy facilities in isolated island , 2005, IEEE Transactions on Energy Conversion.

[53]  Bijaya K. Panigrahi,et al.  Exploratory Power of the Harmony Search Algorithm: Analysis and Improvements for Global Numerical Optimization , 2011, IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics).

[54]  Adriano Carvalho,et al.  Controllable hybrid power system based on renewable energy sources for modern electrical grids , 2013 .

[55]  Shahryar Rahnamayan,et al.  Opposition versus randomness in soft computing techniques , 2008, Appl. Soft Comput..

[56]  Sakti Prasad Ghoshal,et al.  Seeker optimization algorithm for load-tracking performance of an autonomous power system , 2012 .