Effect of thermocouple wire size and attachment method on measurement of thermal characteristics of electronic packages

During thermal characterization and testing of electronic equipment, the temperature of electronic components has to be measured. Thermocouples are commonly used for this purpose. The presence of a thermocouple on the surface of the component causes a local distortion of the temperature field and introduces errors in the measured temperature. This paper reviews the effect of thermocouple size and attachment method on the measurement of surface temperature to determine the thermal characteristics of plastic quad flat pack (PQFP) and tape ball grid array (TBGA) packages. Various size ANSI type T thermocouples were used. The methods of attachment included thermally conductive epoxy, nonthermally conductive epoxy, aluminum tape, and polyimide tape. Thermocouple wire size and attachment method can have a significant effect on the measurement of surface temperature and thermal characterization parameters. Small size and low thermal conductivity thermocouple wires are better to minimize errors due to heat losses through the wires. Using tapes and non-thermally conductive epoxy to attach thermocouples results in larger errors.

[1]  R. P. Benedict,et al.  Manual on the use of thermocouples in temperature measurement , 1974 .

[2]  B. Joiner,et al.  Use of experimental data in guiding thermal specification development , 1996, Twelfth Annual IEEE Semiconductor Thermal Measurement and Management Symposium. Proceedings.

[3]  Kenneth E. Torrance,et al.  Effects of package orientation and mixed convection on heat transfer from a PQFP , 1997 .

[4]  V. B. Dutta Junction-to-case thermal resistance-still a myth? , 1988, Fourth Annual IEEE Semiconductor Thermal and Temperature Measurement Symposium.

[5]  F. E. Romie,et al.  An Investigation of Aircraft Heaters XXVIII : Equations for Steady-State Temperature Distribution Caused by Thermal Sources in Flat Plates Applied to Calculation of Thermocouple Errors, Heat-meter Corrections, and Heat Transfer by Pin-fin Plates , 1948 .

[6]  Allan D. Kraus,et al.  Thermal Analysis and Control of Electronic Equipment , 1983 .

[7]  R. L. Kozarek Effect of case temperature measurement errors on the junction-to-case thermal resistance of a ceramic PGA , 1991, 1991 Proceedings, Seventh IEEE Semiconductor Thermal Measurement and Management Symposium.

[8]  Wataru Nakayama,et al.  Heat Transfer in Electronic Packages , 1997 .

[9]  R. C. Chu,et al.  Conduction cooling for an LSI package: a one-dimensional approach , 1982 .

[10]  Michael A. Gaynes,et al.  Experimental determination of the effect of printed circuit card conductivity on the thermal performance of surface mount electronic packages , 1994, Proceedings of 1994 IEEE/CHMT 10th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM).

[11]  R. Lockhart,et al.  An investigation of aircraft heaters XXXV : thermocouple conduction error observed in measuring surface temperatures , 1951 .