Comparison of Wood Moisture Meters Operating on Different Principles of Measurement

This experiment compared commercially available moisture meters (three capacitive metersand one resistance meter) and tested their predictive ability at different moisture conditions on selected beech (Fagus sylvatica) and spruce (Picea abies (L.) Karst.) wood samples. The measurements were carried out on the samples at specified moisture intervals ranging from 5% to 30% moisture content (MC). The resistance meter showed a close correlation to gravimetric MC values; the influence of the measuring direction for MC below 17% was found when higher MCs in the transverse direction for both species were archieved. The difference was 4.6 times higher for softwood and 1.6 times higher for hardwood. Differences between radial and tangential transverse measuring were not observed. The close correlation coefficient of MC measurements was also found for capacitive methods. The effect of the direction was found for all the tested meters when higher MC values in the longitudinal measurements were found. This effect was especially significant at an MC of wood higher than 20 wt.%. For two capacitive methods, the effect of annual ring deflection only in the spruce samples was found where higher MC values in the tangential direction were observed.

[1]  Vivi Tornari,et al.  Impact of Relative Humidity on Wood Sample: A Climate Chamber Experimental Simulation Monitored by Digital Holographic Speckle Pattern Interferometry , 2019, J. Imaging.

[2]  Dario Camuffo Standardization activity in the evaluation of moisture content , 2018, Journal of Cultural Heritage.

[3]  Christian Brischke,et al.  Material moisture content of wood and cement mortars – Electrical resistance-based measurements in the high ohmic range , 2017 .

[4]  Carlos Morón,et al.  Measurement of Moisture in Wood for Application in the Restoration of Old Buildings , 2016, Sensors.

[5]  Stefan Winter,et al.  Methods to determine wood moisture content and their applicability in monitoring concepts , 2015 .

[6]  Zoubir Mehdi Sbartaï,et al.  Non-destructive evaluation of moisture content of wood material at GPR frequency , 2015 .

[7]  J. Wilgen,et al.  Microwave moisture measurement system for lumber drying , 2007 .

[8]  A. Manninen,et al.  Comparing the Effect of Chemical and Physical Properties on Complex Electrical Impedance of Scots Pine Wood , 2003 .

[9]  M. Tiitta,et al.  Electrical impedance spectroscopy device for measurement of moisture gradients in wood , 2002 .

[10]  A. Hanhijärvi,et al.  Advances in the knowledge of the influence of moisture changes on the long-term mechanical performance of timber structures , 2000 .

[11]  W. M. Daud,et al.  Effect of Moisture Content and Grain Direction on the Dielectric Properties of Rubber Wood at Low Frequencies , 1998 .

[12]  C. Dervos,et al.  The effect of contact capacitance on current-voltage characteristics of stationary metal contacts , 1997, Electrical Contacts - 1997 Proceedings of the Forty-Third IEEE Holm Conference on Electrical Contacts.

[13]  Grigoriy I. Torgovnikov,et al.  Dielectric Properties of Wood and Wood-Based Materials , 1993, Springer Series in Wood Science.

[14]  C. Skaar Wood-Water Relations , 1988, Springer Series in Wood Science.

[15]  H. Vermaas Experimental Variables Affecting the Measurement of the DC Resistance of Wood , 1975 .

[16]  Tadashi Yamada,et al.  The Dielectric Properties of Wood VI : On the Dielectric Properties of the Chemical Constituents of Wood and the Dielectric Anisotropy of Wood , 1972 .

[17]  Alfred J. Stamm,et al.  The Electrical Resistance of Wood as aMeasure of Its Moisture Content , 1927 .