Electrochemical concentration cell ozonesonde performance evaluation during STOIC 1989

Electrochemical concentration cell (ECC) ozonesondes flown by NOAA and NASA Wallops Flight Facility (WFF) personnel during the Stratospheric Ozone Intercomparison Campaign (STOIC) conducted at the Jet Propulsion Laboratory's Table Mountain Facility, Wrightwood, California, July 21 to August 1, 1989, exhibited highly similar ozone measurement precisions and accuracies even though considerably different methods were used by the two research groups in preparing the instruments for use and in calibrating the instruments. The Table Mountain data as well as data obtained in the past showed the precisions to range from about ±3 to ±12% in the troposphere, remain relatively constant at ±3% in the stratosphere to 10 mbar, then decrease to about ±10% at 4-mbar pressure altitude. Corresponding ozone measurement accuracies for individual ozonesonde soundings were estimated to be about ±6% near the ground, decrease to −7 to 17% in the high troposphere where ozone concentrations are low, increase to about ±5% in the low stratosphere and remain so to an altitude of about 10 mbar (∼32 km), then decrease to −14 to 6% at 4 mbar (∼38 km) where ozone concentrations are again low. Stratospheric ozone measurements were also made during STOIC with ground-based lidars and a microwave radiometer that will be used for ozone measurements in the future at sites of the Network for the Detection of Stratospheric Change (NDSC). The ECC ozonesonde observations provided useful comparison data for evaluating the performance of the lidar and microwave instruments.

[1]  T. D. Walsh,et al.  Surface ozone levels at Table Mountain during STOIC 1989 , 1995 .

[2]  Walter D. Komhyr,et al.  Dobson spectrophotometer 83: A standard for total ozone measurements, 1962–1987 , 1989 .

[3]  A. Bandy,et al.  Electrochemical concentration cell ozonesonde accuracy and precision , 1985 .

[4]  B. Connor,et al.  Comparison of STOIC 1989 ground‐based lidar, microwave spectrometer, and Dobson spectrophotometer Umkehr ozone profiles with ozone profiles from balloon‐borne electrochemical concentration cell ozonesondes , 1995 .

[5]  N. Perry,et al.  Book Reviews : Introduction to Mathematical Statistics (2nd Ed.), by Paul G. Hoel. New York: John Wiley and Sons, Inc., I954. Pp. xi + 33I. $5.00 , 1955 .

[6]  W. Evans,et al.  Results from the balloon ozone intercomparison campaign (BOIC) , 1986 .

[7]  R. J. Paur,et al.  The ultraviolet cross-sections of ozone. I. The measurements. II - Results and temperature dependence , 1985 .

[8]  W. Komhyr,et al.  Development of an ECC Ozonesonde , 1971 .

[9]  S. Oltmans,et al.  Performance Characteristics of High-Altitude ECC Ozonesondes , 1985 .

[10]  W. Komhyr Nonreactive Gas Sampling Pump , 1967 .

[11]  Ernest Vigroux,et al.  Contribution à l'étude expérimentale de l'absorption de l'ozone , 1953 .

[12]  C. Parsons,et al.  Radiosonde Pressure Sensor Performance: Evaluation Using Tracking Radars , 1984 .

[13]  W. J. Youden Statistical methods for chemists , 1951 .

[14]  J. Kerr,et al.  Total ozone measurements made with the Brewer ozone spectrophotometer during STOIC 1989 , 1995 .

[15]  E. Vigroux Détermination des coefficients moyens d'absorption de l'ozone en vue des observations concernant l'ozone atmosphérique à l'aide du spectromètre dobson , 1967 .

[16]  William P. Chu,et al.  Comparison of ozone profiles from ground-based lidar, electrochemical concentration cell balloon sonde, ROCOZ-A rocket ozonesonde, and Stratospheric Aerosol and Gas Experiment satellite measurements , 1990 .

[17]  W. Komhyr,et al.  Dobson spectrophotometer total ozone measurement errors caused by interfering absorbing species such as SO2, NO2, and photochemically produced O3 in polluted air , 1980 .

[18]  R. Barnes,et al.  Electrochemical concentration cell ozone soundings at two sites during the Stratospheric Ozone Intercomparison Campaign , 1995 .

[19]  T. D. Walsh,et al.  STRATOSPHERIC OZONE INTERCOMPARISON CAMPAIGN (STOIC) 1989 : OVERVIEW , 1995 .

[20]  D. Thornton,et al.  Sources of background current in thr ECC ozonesonde: Implications for total ozone measurements , 1982 .

[21]  A. P. Altshuller,et al.  Analysis of the oxidant in photooxidation reactions , 1967 .