Imaging Mass Spectrometry Using a Delay-Line Detector

Microscope mode mass spectrometric imaging is crucially dependent on the availability of a high-resolution, position-resolved time-of-flight detector. Here, a new detection method for microscope mode imaging mass spectrometry is presented. A delay-line detector has been used for the first time as a position-sensitive detector in imaging mass spectrometry. The method is implemented on a matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF), as well as a secondary ion mass spectrometry time-of-flight (SIMS-ToF) instrument. Trypsinogen and bovine serum albumin samples have been used with a metal mask to determine the spatial resolution of the new detector using the MALDI-ToF instrument. The new detector set-up was successfully employed to generate mass resolved SIMS images from biological structures on the surface of thin tissue sections. The biological samples studied were taken from tumor grown from xenografted breast cancer cell lines and chicken embryonal sections.

[1]  R. Caprioli,et al.  Molecular imaging of biological samples: localization of peptides and proteins using MALDI-TOF MS. , 1997, Analytical chemistry.

[2]  Simone Stumbo,et al.  MEDIPIX: a VLSI chip for a GaAs pixel detector for digital radiology , 1999 .

[3]  A. Poustka,et al.  Systematic subcellular localization of novel proteins identified by large‐scale cDNA sequencing , 2000, EMBO reports.

[4]  M. Stoeckli,et al.  Imaging mass spectrometry: A new technology for the analysis of protein expression in mammalian tissues , 2001, Nature Medicine.

[5]  Oliver G. Schmidt,et al.  Microspectroscopy and imaging using a delay line detector in time-of-flight photoemission microscopy , 2001 .

[6]  O. Jagutzki,et al.  Multiple hit read-out of a microchannel plate detector with a three-layer delay-line anode , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[7]  G. Schönhense,et al.  Time-of-flight photoemission electron microscopy – a new way to chemical surface analysis , 2001 .

[8]  M. Gerstein,et al.  Subcellular localization of the yeast proteome. , 2002, Genes & development.

[9]  R. Tsien,et al.  Creating new fluorescent probes for cell biology , 2002, Nature Reviews Molecular Cell Biology.

[10]  Lutz Spielberger,et al.  A broad-application microchannel-plate detector system for advanced particle or photon detection tasks: large area imaging, precise multi-hit timing information and high detection rate , 2002 .

[11]  S. Hanash,et al.  Disease proteomics , 2003, Nature.

[12]  Roger Y. Tsien,et al.  Creating new fluorescent probes for cell biology , 2003, Nature Reviews Molecular Cell Biology.

[13]  R. Aebersold,et al.  Mass spectrometry-based proteomics , 2003, Nature.

[14]  S. Fields,et al.  Protein analysis on a proteomic scale , 2003, Nature.

[15]  S. Hanash Disease proteomics : Proteomics , 2003 .

[16]  L. McDonnell,et al.  High-spatial resolution mass spectrometric imaging of peptide and protein distributions on a surface. , 2004, Analytical chemistry.

[17]  L. McDonnell,et al.  Infrared mass spectrometric imaging below the diffraction limit. , 2005, Journal of proteome research.

[18]  Sander R Piersma,et al.  Subcellular imaging mass spectrometry of brain tissue. , 2005, Journal of mass spectrometry : JMS.

[19]  Sander R. Piersma,et al.  Why don't biologists use SIMS? A critical evaluation of imaging MS , 2006 .

[20]  A. Altelaar,et al.  The influence of the cholesterol microenvironment in tissue sections on molecular ionization efficiencies and distributions in ToF-SIMS , 2006 .

[21]  Kees Jalink,et al.  Gold-enhanced biomolecular surface imaging of cells and tissue by SIMS and MALDI mass spectrometry. , 2006, Analytical chemistry.

[22]  R. Caprioli,et al.  Direct molecular analysis of whole-body animal tissue sections by imaging MALDI mass spectrometry. , 2006, Analytical chemistry.

[23]  I. Fournier,et al.  MALDI-MS direct tissue analysis of proteins: Improving signal sensitivity using organic treatments. , 2006, Analytical chemistry.

[24]  Liam A. McDonnell,et al.  Imaging of peptides in the rat brain using MALDI-FTICR mass spectrometry , 2007, Journal of the American Society for Mass Spectrometry.

[25]  M. Stoeckli,et al.  Compound and metabolite distribution measured by MALDI mass spectrometric imaging in whole-body tissue sections , 2007 .

[26]  Liam A McDonnell,et al.  Imaging mass spectrometry. , 2007, Mass spectrometry reviews.

[27]  L. McDonnell,et al.  Imaging mass spectrometry at cellular length scales , 2007, Nature Protocols.

[28]  P. Dankers,et al.  C60+ secondary ion microscopy using a delay line detector. , 2010, Analytical chemistry.