In Vivo Imaging of Exogenous Progenitor Cells in Tendon Regeneration via Superparamagnetic Iron Oxide Particles

Background: Although tendon injuries and repairs are common, treatment of these injuries has limitations. The application of mesenchymal progenitor cells (MPCs) is increasingly used to optimize the biological process of tendon repair healing. However, clinically relevant technologies that effectively assess the localization of exogenous MPCs in vivo are lacking. Hypothesis: Exogenous MPCs labeled with superparamagnetic iron oxide (SPIO) particles would allow monitoring of the localization and retention of cells within the site of implantation via magnetic resonance imaging (MRI) without negatively affecting cell survival or differentiation. Study Design: Descriptive laboratory study. Methods: Genetically modified C3H10T1/2 MPCs engineered to express luciferase (Luc+) reporter gene were implanted into surgically created Achilles tendon defects of 10 athymic nude rats (Hsd:RH-Foxn1rnu). Of these animals, 5 animals received Luc+ C3H10T1/2 MPCs colabeled with SPIO nanoparticles (+SPIO). These 2 groups of animals then underwent optical imaging with quantification of bioluminescence and MRI at 7, 14, and 28 days after surgery. Statistical analysis was conducted by use of 2-way analysis of variance. At 28 days after surgery, animals were euthanized and the treated limbs underwent histologic analysis. Results: Optical imaging demonstrated that the implanted cells not only survived but also proliferated in vivo, and these cells remained viable for at least 4 weeks after implantation. In addition, SPIO labeling did not appear to affect MPC survival or proliferation, as assessed by quantitative bioluminescence imaging (P > .05, n = 5). MRI demonstrated that SPIO labeling was an effective method to monitor cell localization, retention, and viability for at least 4 weeks after implantation. Histologic and immunofluorescence analyses of the repaired tendon defect sites demonstrated tenocyte-like labeled cells, suggesting that cell differentiation was not affected by labeling the cells with the SPIO nanoparticles. Conclusion: MRI of exogenous MPCs labeled with SPIO particles allows for effective in vivo assessments of cell localization and retention in the setting of tendon regeneration for at least 4 weeks after implantation. This SPIO labeling does not appear to impair cell survival, transgene expression, or differentiation. Clinical Relevance: SPIO labeling of MPCs appears to be safe for in vivo assessments of MPCs in tendon regeneration therapies and may be used for future clinical investigations of musculoskeletal regenerative medicine.

[1]  Y. X. Wáng,et al.  A comprehensive literatures update of clinical researches of superparamagnetic resonance iron oxide nanoparticles for magnetic resonance imaging. , 2017, Quantitative imaging in medicine and surgery.

[2]  R. van Weeren,et al.  Tracking of autologous adipose tissue-derived mesenchymal stromal cells with in vivo magnetic resonance imaging and histology after intralesional treatment of artificial equine tendon lesions - a pilot study , 2016, Stem Cell Research & Therapy.

[3]  W. Brehm,et al.  Longitudinal Cell Tracking and Simultaneous Monitoring of Tissue Regeneration after Cell Treatment of Natural Tendon Disease by Low-Field Magnetic Resonance Imaging , 2016, Stem cells international.

[4]  J. Mumaw,et al.  Superparamagnetic iron oxide nanoparticles as a means to track mesenchymal stem cells in a large animal model of tendon injury. , 2015, Contrast media & molecular imaging.

[5]  A. Purushotham,et al.  Novel techniques for sentinel lymph node biopsy in breast cancer: a systematic review. , 2014, The Lancet. Oncology.

[6]  Benjamin B. Rothrauff,et al.  Cellular therapy in bone-tendon interface regeneration , 2014, Organogenesis.

[7]  Gerald R. Williams,et al.  The societal and economic value of rotator cuff repair. , 2013, The Journal of bone and joint surgery. American volume.

[8]  Freddie H. Fu,et al.  Superparamagnetic Iron Oxide is Suitable to Label Tendon Stem Cells and Track Them In Vivo with MR Imaging , 2013, Annals of Biomedical Engineering.

[9]  Ralph Müller,et al.  Smad8/BMP2‐engineered mesenchymal stem cells induce accelerated recovery of the biomechanical properties of the achilles tendon , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  Gao-Jun Teng,et al.  Labeling and tracing of bone marrow mesenchymal stem cells for tendon-to-bone tunnel healing , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[11]  Gabriel P. Krestin,et al.  Clinically Translatable Cell Tracking and Quantification by MRI in Cartilage Repair Using Superparamagnetic Iron Oxides , 2011, PloS one.

[12]  I. Cuthill,et al.  Reporting : The ARRIVE Guidelines for Reporting Animal Research , 2010 .

[13]  M. Provencher,et al.  Does the literature confirm superior clinical results in radiographically healed rotator cuffs after rotator cuff repair? , 2010, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[14]  P. Robinson,et al.  Sinusoidal obstructive syndrome diagnosed with superparamagnetic iron oxide-enhanced magnetic resonance imaging in patients with chemotherapy-treated colorectal liver metastases. , 2008, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[15]  D. Jirák,et al.  Magnetic resonance imaging of pancreatic islets transplanted into the right liver lobes of diabetic mice. , 2008, Transplantation proceedings.

[16]  Brian K Rutt,et al.  In vivo MRI of cancer cell fate at the single‐cell level in a mouse model of breast cancer metastasis to the brain , 2006, Magnetic resonance in medicine.

[17]  Gil Navon,et al.  Neotendon formation induced by manipulation of the Smad8 signalling pathway in mesenchymal stem cells. , 2006, The Journal of clinical investigation.

[18]  Chris Heyn,et al.  In vivo magnetic resonance imaging of single cells in mouse brain with optical validation , 2006, Magnetic resonance in medicine.

[19]  William D Middleton,et al.  The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. , 2004, The Journal of bone and joint surgery. American volume.

[20]  B. Marincek,et al.  Detection of liver metastases: comparison of superparamagnetic iron oxide-enhanced and unenhanced MR imaging at 1.5 T with dynamic CT, intraoperative US, and percutaneous US. , 1995, Radiology.

[21]  D. Kraitchman,et al.  MR imaging of transplanted stem cells in myocardial infarction. , 2011, Methods in molecular biology.