Emulation of the laparoscopic environment for image-guided liver surgery via an abdominal phantom system with anatomical ligamenture

In order to rigorously validate techniques for image-guided liver surgery (IGLS), an accurate mock representation of the intraoperative surgical scene with quantifiable localization of subsurface targets would be highly desirable. However, many attempts to reproduce the laparoscopic environment have encountered limited success due to neglect of several crucial design aspects. The laparoscopic setting is complicated by factors such as gas insufflation of the abdomen, changes in patient orientation, incomplete organ mobilization from ligaments, and limited access to organ surface data. The ability to accurately represent the influences of anatomical changes and procedural limitations is critical for appropriate evaluation of IGLS methodologies such as registration and deformation correction. However, these influences have not yet been comprehensively integrated into a platform usable for assessment of methods in laparoscopic IGLS. In this work, a mock laparoscopic liver simulator was created with realistic ligamenture to emulate the complexities of this constrained surgical environment for the realization of laparoscopic IGLS. The mock surgical system reproduces an insufflated abdominal cavity with dissectible ligaments, variable levels of incline matching intraoperative patient positioning, and port locations in accordance with surgical protocol. True positions of targets embedded in a tissue-mimicking phantom are measured from CT images. Using this setup, image-to-physical registration accuracy was evaluated for simulations of laparoscopic right and left lobe mobilization to assess rigid registration performance under more realistic laparoscopic conditions. Preliminary results suggest that non-rigid organ deformations and the region of organ surface data collected affect the ability to attain highly accurate registrations in laparoscopic applications.

[1]  Logan W. Clements,et al.  Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation. , 2008, Medical physics.

[2]  T. Frank,et al.  Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery , 2006, Surgical Endoscopy And Other Interventional Techniques.

[3]  K. Cleary,et al.  Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine. , 2005, Medical physics.

[4]  Sébastien Ourselin,et al.  Accuracy validation of an image guided laparoscopy system for liver resection , 2015, Medical Imaging.

[5]  Logan W. Clements,et al.  Evolution of Image-Guided Liver Surgery: Transition from Open to Laparoscopic Procedures , 2013, Journal of Gastrointestinal Surgery.

[6]  D. Caleb Rucker,et al.  A Mechanics-Based Nonrigid Registration Method for Liver Surgery Using Sparse Intraoperative Data , 2014, IEEE Transactions on Medical Imaging.

[7]  Heinz-Otto Peitgen,et al.  Assessment of Intraoperative Liver Deformation During Hepatic Resection: Prospective Clinical Study , 2010, World Journal of Surgery.

[8]  D. Caleb Rucker,et al.  Registration of liver images to minimally invasive intraoperative surface and subsurface data , 2014, Medical Imaging.

[9]  Erlend Fagertun Hofstad,et al.  Navigated laparoscopy – liver shift and deformation due to pneumoperitoneum in an animal model , 2012, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[10]  Amber L. Simpson,et al.  A study on the theoretical and practical accuracy of conoscopic holography‐based surface measurements: toward image registration in minimally invasive surgery , 2012, The international journal of medical robotics + computer assisted surgery : MRCAS.

[11]  B. Malassagne,et al.  Laparoscopic Liver Resections: A Feasibility Study in 30 Patients , 2000, Annals of surgery.

[12]  Michael I Miga,et al.  Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound , 2016, Journal of medical imaging.

[13]  Ho-Seong Han,et al.  Outcomes of laparoscopic liver resection for lesions located in the right side of the liver. , 2009, Archives of surgery.

[14]  Robert J. Webster,et al.  Minimally Invasive Holographic Surface Scanning for Soft-Tissue Image Registration , 2010, IEEE Transactions on Biomedical Engineering.