Bispectral Index Does Not Correlate with Observer Assessment of Alertness and Sedation Scores During 0.5% Bupivacaine Epidural Anesthesia with Nitrous Oxide Sedation

The bispectral index (BIS) has been used as a measure of the degree of sedation and level of hypnosis for IV hypnotics and sedatives, potent volatile anesthetics. We evaluated the effect of increasing concentrations of nitrous oxide (N2O) on BIS and compared it with the Observer's Assessment of Alertness and Sedation (OAA/S) scale in patients undergoing regional anesthesia. We studied 48 unpremedicated, ASA physical status I–II adult patients scheduled for lower extremity surgery under lumbar epidural anesthesia. N2O was given in oxygen to achieve measured end-tidal concentrations of 33%, 50%, and 67% N2O by a tight-fitting facemask, and each N2O concentration was maintained for 20 min. Paired measurements of BIS and OAA/S scores were obtained just before each increase in N2O concentration. Forty of the 48 subjects completed the study. Increasing N2O concentrations produced no changes in BIS despite a significant decrease in OAA/S scores at 50% and 67% N2O concentrations. The prediction probability for BIS and OAA/S calculated by Somers' dx · y were 0.60 and 0.84, respectively. Anesthesiologists should be aware that the BIS monitor may not be sensitive enough to provide an adequate measure of the depth of sedation and hypnosis when using N2O alone for sedation. It may be better to monitor sedation clinically (e.g., with the OAA/S scale) to determine the dose requirement and the adequacy of depth of sedation and hypnosis.

[1]  P Manberg,et al.  Bispectral Analysis Measures Sedation and Memory Effects of Propofol, Midazolam, Isoflurane, and Alfentanil in Healthy Volunteers , 1997, Anesthesiology.

[2]  L. Kearse,et al.  Bispectral Analysis of the Electroencephalogram Predicts Conscious Processing of Information during Propofol Sedation and Hypnosis , 1998, Anesthesiology.

[3]  T. Short,et al.  Isoflurane Dosage for Equivalent Intraoperative Electroencephalographic Suppression in Patients With and Without Epidural Blockade , 2002, Anesthesia and analgesia.

[4]  R. Rodriguez,et al.  The bispectral index does not correlate with clinical signs of inhalational anesthesia during sevoflurane induction and arousal in children , 2004, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[5]  T. Koitabashi,et al.  [The effect of nitrous oxide on the central nervous system evaluated by the bispectral index under various levels of propofol anesthesia]. , 2004, Masui. The Japanese journal of anesthesiology.

[6]  M. Puig,et al.  Isoflurane Requirements During Combined General/Epidural Anesthesia for Major Abdominal Surgery , 2002, Anesthesia and analgesia.

[7]  C Thornton,et al.  Auditory evoked response, median frequency and 95% spectral edge during anaesthesia with desflurane and nitrous oxide. , 1997, British journal of anaesthesia.

[8]  D. Sessler,et al.  Block-dependent sedation during epidural anaesthesia is associated with delayed brainstem conduction. , 2004, British journal of anaesthesia.

[9]  C. Kalkman,et al.  A comparison of the effects of propofol and nitrous oxide on the electroencephalogram in epileptic patients during conscious sedation for dental procedures. , 1992, Anesthesia and analgesia.

[10]  B. Seifert,et al.  Clonidine decreases propofol requirements during anaesthesia: effect on bispectral index. , 2001, British journal of anaesthesia.

[11]  A. Bjorksten,et al.  Automated responsiveness test and bispectral index monitoring during propofol and propofol/N2O sedation , 2003, Acta anaesthesiologica Scandinavica.

[12]  G D Puri,et al.  Paradoxical changes in bispectral index during nitrous oxide administration. , 2001, British journal of anaesthesia.

[13]  Spencer S. Liu Effects of Bispectral Index Monitoring on Ambulatory Anesthesia: A Meta-analysis of Randomized Controlled Trials and a Cost Analysis , 2004, Anesthesiology.

[14]  E Konecny,et al.  Middle latency auditory evoked responses and electroencephalographic derived variables do not predict movement to noxious stimulation during 1 minimum alveolar anesthetic concentration isoflurane/nitrous oxide anesthesia. , 1999, Anesthesia and analgesia.

[15]  Spencer S. Liu,et al.  Epidural Lidocaine Decreases Sevoflurane Requirement for Adequate Depth of Anesthesia as Measured by the Bispectral Index ® Monitor , 2001, Anesthesiology.

[16]  Chiharu Negishi,et al.  Bispectral EEG Index during Nitrous Oxide Administration , 1998, Anesthesiology.

[17]  J. Jakobsson,et al.  Nitrous oxide does not alter bispectral index: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesia. , 1999, British journal of anaesthesia.

[18]  J. Jakobsson,et al.  Entropy of EEG during anaesthetic induction: a comparative study with propofol or nitrous oxide as sole agent. , 2004, British journal of anaesthesia.

[19]  A. Shono,et al.  Comparison of 1% and 2% lidocaine epidural anaesthesia combined with sevoflurane general anaesthesia utilizing a constant bispectral index. , 2003, British journal of anaesthesia.

[20]  J. Sleigh,et al.  Entropy is blind to nitrous oxide. Can we see why? , 2004, British journal of anaesthesia.

[21]  T. Matsukawa,et al.  Ephedrine, but Not Phenylephrine, Increases Bispectral Index Values During Combined General and Epidural Anesthesia , 2003, Anesthesia and analgesia.

[22]  C. Ménigaux,et al.  Nitrous Oxide Prevents Movement During Orotracheal Intubation Without Affecting BIS Value , 2000, Anesthesia and analgesia.

[23]  M. Pellegrini,et al.  Effects of fentanyl, alfentanil, remifentanil and sufentanil on loss of consciousness and bispectral index during propofol induction of anaesthesia. , 2001, British journal of anaesthesia.

[24]  S. Nasraway,et al.  How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study* , 2002, Critical care medicine.

[25]  Warren D. Smith,et al.  Measuring the Performance of Anesthetic Depth Indicators , 1996, Anesthesiology.

[26]  D. Chernik,et al.  Validity and Reliability of the Observer's: Assessment of Alertness/Sedation Scale Study with Intravenous Midazolam , 1990, Journal of clinical psychopharmacology.

[27]  J. Mantz Évaluation de la profondeur de la sédation en neuroréanimation : les scores cliniques, les méthodes électrophysiologiques et le BIS , 2004 .

[28]  J. Brichant,et al.  Effect of epidural bupivacaine on the relationship between the bispectral index and end‐expiratory concentrations of desflurane , 1999, Anaesthesia.

[29]  H Ishihara,et al.  The effects of nitrous oxide and ketamine on the bispectral index and 95% spectral edge frequency during propofol-fentanyl anaesthesia. , 1999, European journal of anaesthesiology.