A novel control scheme for DFIG-based wind energy systems under unbalanced grid conditions

This paper presents an analysis and a novel control scheme for a doubly fed induction generator (DFIG) based wind energy generation under unbalanced grid voltage conditions. The control objectives are: (i) to limit the rotor currents, (ii) to suppress ripples in the torque and (iii) to suppress the dc-link voltage fluctuation through converter controls. Negative sequence compensation techniques by one of the converters, namely, the rotor side converter (RSC) or the grid side converter (GSC) in a DFIG are discussed and their limitations are presented. A coordinated control scheme with a concise structure compared to the conventional dual sequence control structure is proposed in this paper. The RSC is controlled to suppress ripples in the torque and the rotor currents while the GSC is controlled to suppress ripples in the dc-link voltage by considering the rotor power effect. The major contributions of the paper include: (i) the presentation of the limitation of negative sequence compensation using one converter; (ii) development of a concise coordination control scheme which is free of low pass filters and uses a reduced number of reference frame transformation. Matlab/Simulink tests for a 2MW DFIG demonstrate the effectiveness of the control scheme.

[1]  Jiabing Hu,et al.  Modeling and Control of Grid-Connected Voltage-Sourced Converters Under Generalized Unbalanced Operation Conditions , 2008, IEEE Transactions on Energy Conversion.

[2]  Ned Mohan,et al.  Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions , 2005 .

[3]  Lie Xu,et al.  Coordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance , 2008, IEEE Transactions on Power Electronics.

[4]  O. Gomis-Bellmunt,et al.  Ride-Through Control of a Doubly Fed Induction Generator Under Unbalanced Voltage Sags , 2008, IEEE Transactions on Energy Conversion.

[5]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[6]  J. López,et al.  Wind Turbines Based on Doubly Fed Induction Generator Under Asymmetrical Voltage Dips , 2008, IEEE Transactions on Energy Conversion.

[7]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[8]  Lie Xu,et al.  Enhanced Control and Operation of DFIG-Based Wind Farms During Network Unbalance , 2008, IEEE Transactions on Energy Conversion.

[9]  J. Clare,et al.  Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction Generators , 2007, IEEE Transactions on Energy Conversion.

[10]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[11]  Lingling Fan,et al.  Harmonic Analysis of a DFIG for a Wind Energy Conversion System , 2010, IEEE Transactions on Energy Conversion.

[12]  S. Arnalte,et al.  Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[13]  Hui Li,et al.  An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator , 2008, IEEE Transactions on Power Electronics.

[14]  J.A. Ferreira,et al.  Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition , 2009, IEEE Transactions on Energy Conversion.

[15]  Eduard Muljadi,et al.  Understanding the unbalanced-voltage problem in wind turbine generation , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[16]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[17]  D. Santos-Martin,et al.  Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage Dips , 2009, IEEE Transactions on Power Electronics.

[18]  S.K. Panda,et al.  Analysis of the Instantaneous Power Flow for Three-Phase PWM Boost Rectifier Under Unbalanced Supply Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[19]  Barry W. Williams,et al.  Improved Control of DFIG Systems During Network Unbalance Using PI–R Current Regulators , 2009, IEEE Transactions on Industrial Electronics.

[20]  Lingling Fan,et al.  Control of DFIG for rotor current harmonics elimination , 2009, 2009 IEEE Power & Energy Society General Meeting.

[21]  Jiabing Hu,et al.  Modeling and enhanced control of DFIG under unbalanced grid voltage conditions , 2009 .

[22]  Frede Blaabjerg,et al.  Proportionalresonant controllers and filters for gridconnected voltagesource converters , 2006 .

[23]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[24]  Lingling Fan,et al.  Negative sequence compensation techniques of DFIG-based wind energy systems under unbalanced grid conditions , 2009, 2009 IEEE Power Electronics and Machines in Wind Applications.

[25]  雷蒙德·M·胡德松 Control system for doubly fed induction generator , 2004 .