Imageless Navigated Posterior Minimally Invasive Total Hip Replacement with the Orthosoft Navitrack System

not account for the imprecision associated with reaming or cup placement during surgery [9]. Imageless technology allows real-time intra-operative knowledge of the quantitative direction and depth of reaming; adjustment during reaming for variations in the bony anatomy to allow for correct cup coverage with optimal inclination; and allows adjustment of the anteversion of a cup to a desired combined anteversion through knowledge of the fixed femoral anteversion. In this study we determined the accuracy of, and reproducibility of, measurements of inclination, anteversion, and reproduction of the correct center of rotation of the acetabulum using the Orthosoft navigation program. Pelvic tilt was used to adjust the inclination and anteversion. Radiographs do not reflect the accuracy of the computer. The computer allows accurate real-time control of the placement of the acetabular components. If the femoral preparation is done first, so that the anteversion of the femoral component is known, the acetabulum can be customized for each patient to achieve a combined prosthetic mean anteversion of 35 +/– 5 degrees. The computer improved the skill of the surgeon to correctly and reproducibly implant the components.

[1]  H. Uhthoff,et al.  Anteversion of the acetabular cup. Measurement of angle after total hip replacement. , 1986, The Journal of bone and joint surgery. British volume.

[2]  J. Lewis,et al.  Dislocations after total hip-replacement arthroplasties. , 1978, The Journal of bone and joint surgery. American volume.

[3]  T D Brown,et al.  A Finite Element Analysis of Factors Influencing Total Hip Dislocation , 1998, Clinical orthopaedics and related research.

[4]  Brigitte M Jolles,et al.  Computer-assisted Cup Placement Techniques in Total Hip Arthroplasty Improve Accuracy of Placement , 2004, Clinical orthopaedics and related research.

[5]  D. Murray The definition and measurement of acetabular orientation. , 1993, The Journal of bone and joint surgery. British volume.

[6]  T. Wright,et al.  Impingement in total hip arthroplasty a study of retrieved acetabular components. , 2005, The Journal of arthroplasty.

[7]  L. Dorr,et al.  Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant. , 1996, The Journal of arthroplasty.

[8]  D R Laster,et al.  Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling. , 2001, The Journal of arthroplasty.

[9]  B Jaramaz,et al.  Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Alignment , 1998, Clinical orthopaedics and related research.

[10]  D. D’Lima,et al.  The Effect of the Orientation of the Acetabular and Femoral Components on the Range of Motion of the Hip at Different Head-Neck Ratios* , 2000, The Journal of bone and joint surgery. American volume.

[11]  W. Capello,et al.  Morphologic Features of the Acetabulum and Femur: Anteversion Angle and Implant Positioning , 2001, Clinical orthopaedics and related research.

[12]  D. Vandevelde,et al.  Reduction in Variability of Acetabular Cup Abduction Using Computer Assisted Surgery: A Prospective and Randomized Study , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  Branislav Jaramaz,et al.  Comparison of a mechanical acetabular alignment guide with computer placement of the socket. , 2002, The Journal of arthroplasty.

[14]  J. Charnley,et al.  The nine and ten year results of the low-friction arthroplasty of the hip. , 1973, Clinical orthopaedics and related research.

[15]  Shantanu Patil,et al.  Polyethylene Wear and Acetabular Component Orientation , 2003, The Journal of bone and joint surgery. American volume.

[16]  Thomas P Sculco,et al.  Minimally invasive total hip arthroplasty: a prospective randomized study. , 2004, The Journal of arthroplasty.

[17]  B. Jaramaz,et al.  Computer Assisted Measurement of Cup Placement in Total Hip Replacement , 1998, Clinical orthopaedics and related research.

[18]  L. Dorr,et al.  Operative and Patient Care Techniques for Posterior Mini-incision Total Hip Arthroplasty , 2005, Clinical orthopaedics and related research.

[19]  Branislav Jaramaz,et al.  Mini-incision technique for total hip arthroplasty with navigation. , 2003, The Journal of arthroplasty.

[20]  L. Amiot,et al.  Computed Tomography-Based Navigation for Hip, Knee, and Spine Surgery , 2004, Clinical orthopaedics and related research.

[21]  John J. Callaghan,et al.  Minimally invasive total hip arthroplasty. Development, early results, and a critical analysis. Presented at the Annual Meeting of the American Orthopaedic Association, Charleston, South Carolina, USA, June 14, 2003. , 2003, The Journal of bone and joint surgery. American volume.

[22]  P. D. Wilson,et al.  Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. , 1985, The Journal of bone and joint surgery. American volume.

[23]  T. Bauer,et al.  The spatial location of impingement in total hip arthroplasty. , 2000, The Journal of arthroplasty.

[24]  R. Barrack,et al.  Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. , 2001, The Orthopedic clinics of North America.

[25]  N. Zacharakis,et al.  A 12- to 18-year radiographic follow-up study of Charnley low-friction arthroplasty. The role of the center of rotation. , 1993, Clinical orthopaedics and related research.

[26]  L. Dorr Hip arthroplasty : minimally invasive techniques and computer navigation , 2006 .

[27]  Dean D. Newton,et al.  Development of imageless computer navigation for acetabular component position in total hip replacement. , 2005, The Iowa orthopaedic journal.