Estimation of the Local Statistical Noise in Emission Computed Tomography

A simple modification of the filtered backprojection algorithm is presented for the computation of the local statistical noise in emission computed tomography. The technique is general in that any distribution of radioactivity may be accommodated. When applied to positron emission tomography, it is shown that the effects of photon absorption, random coincidences, radioactive decay, and detector nonuniformity may be included. Calculations have shown the effects of resolution, object size, and photon absorption on the statistical noise of disk-shaped emitters. Comparison of calculation and experiment show close agreement both in magnitude and spatial variation. Measurements of the noise level in tomograms of the brain obtained during continuous inhalation of 150-CO2 demonstrate that estimates of radioactivity concentration with a precision of a few percent are readily attainable.

[1]  G L Brownell,et al.  A model for regional cerebral oxygen distribution during continuous inhalation of 15O2, C15O, and C15O2. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  M E Phelps,et al.  ECAT: a new computerized tomographic imaging system for positron-emitting radiopharmaceuticals. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  N. Alpert,et al.  Properties Of The Mgh Positron Camera For Brain Imaging , 1978 .

[4]  G L Brownell,et al.  Positron imaging in ischemic stroke disease using compounds labeled with oxygen 15. Initial results of clinicophysiologic correlations. , 1981, Archives of neurology.

[5]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[6]  M E Phelps,et al.  Positron emission tomography. , 1979, Medical instrumentation.

[7]  W Simon,et al.  Attenuation Correction in Gamma Emission Computed Tomography , 1981, Journal of computer assisted tomography.

[8]  G T Gullberg,et al.  Quantitative potentials of dynamic emission computed tomography. , 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  R. Frackowiak,et al.  Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission Tomography: Theory, Procedure, and Normal Values , 1980, Journal of computer assisted tomography.

[10]  E. Hoffman,et al.  A BOUNDARY METHOD FOR ATTENUATION CORRECTION IN POSITRON COMPUTED TOMOGRAPHY , 1981, Journal of Nuclear Medicine.

[11]  S J Riederer,et al.  Noise Due to Photon Counting Statistics in Computed X‐Ray Tomography , 1977, Journal of computer assisted tomography.

[12]  W. Swindell,et al.  Analog reconstruction methods for transaxial tomography , 1977, Proceedings of the IEEE.

[13]  T. Budinger,et al.  Three-dimensional reconstruction in nuclear medicine emission imaging , 1974 .

[14]  S J Riederer,et al.  Ripple suppression during reconstruction in transverse tomography. , 1975, Physics in medicine and biology.

[15]  E. Hoffman,et al.  Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction. , 1979, Journal of computer assisted tomography.

[16]  R H Huesman,et al.  The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstruction. , 1977, Physics in medicine and biology.

[17]  G T Gullberg,et al.  Emission Computer Assisted Tomography with Single‐Photon and Positron Annihilation Photon Emitters , 1977, Journal of computer assisted tomography.