Toward Stand-Off Open-Path Measurements of NO and NO2 in the Sub-Parts Per Million Meter Range Using Quantum Cascade Lasers (QCLs) in the Intra-Pulse Absorption Mode

Two thermoelectrically cooled mid-infrared distributed feedback quantum cascade lasers operated in pulsed mode have been used for the quasi-simultaneous determination of NO and NO2 in the sub-parts per million meter (sub-ppm-m) range. Using a beam splitter, the beams of the two lasers were combined and sent to a retro-reflector. The returned light was recorded with a thermoelectrically cooled mercury cadmium telluride detector with a rise time of 4 ns. Alternate operation of the lasers with pulse lengths of 300 ns and a repetition rate of 66 kHz allowed quasi-simultaneous measurements. During each pulse the laser temperature increased, causing a thermal chirp of the laser line of up to 1.3 cm−1. These laser chirps were sufficient to scan rotational bands of NO centered at 1902 cm−1 and NO2 located at 1632 cm−1. In that way an absorption spectrum could be recorded from a single laser pulse. Currently achieved limits of detection are 600 parts per billion meter (ppb-m) for NO and 260 ppb-m for NO2 using signal averaging over 1 min. This work presents the first steps toward a portable stand-off, open-path instrument that uses thermoelectrically cooled detector and lasers.

[1]  Wolfhard Wegscheider,et al.  Validation of Analytical Methods , 1996 .

[2]  Fast Scanning Laser DOAS for Local Monitoring of Trace Gases, in Particular Tropospheric OH Radicals , 1992 .

[3]  Xiaoji Niu,et al.  Analysis and Modeling of Inertial Sensors Using Allan Variance , 2008, IEEE Transactions on Instrumentation and Measurement.

[4]  Luc Int Panis,et al.  Subclinical responses in healthy cyclists briefly exposed to traffic-related air pollution: an intervention study , 2010, Environmental health : a global access science source.

[5]  Zhiliang Yao,et al.  NOx emission trends for China, 1995–2004: The view from the ground and the view from space , 2007 .

[6]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[7]  Robert A. Toth,et al.  High-resolution measurements and analysis of 14 N 16 O 2 in the (001)-(000) and (011)-(010) bands , 1992 .

[8]  W. J. Lafferty,et al.  Analysis of the ν3 band of 14N16O2 , 1974 .

[9]  Photoacoustic spectroscopy for trace gas detection with cryogenic and room-temperature continuous-wave quantum cascade lasers , 2010 .

[10]  Ronald K. Hanson,et al.  Wavelength-modulation-spectroscopy for real-time, in situ NO detection in combustion gases with a 5.2 μm quantum-cascade laser , 2012 .

[11]  David D. Nelson,et al.  Pulsed quantum cascade laser instrument with compact design for rapid, high sensitivity measurements of trace gases in air , 2008 .

[12]  Andreas Karpf,et al.  Extremely sensitive detection of NO₂ employing off-axis integrated cavity output spectroscopy coupled with multiple-line integrated absorption spectroscopy. , 2011, Applied optics.

[13]  M. D. Tucker,et al.  Open-path Fourier transform infrared spectroscopy , 1999 .

[14]  Frank K. Tittel,et al.  NO trace gas sensor based on quartz-enhanced photoacoustic spectroscopy and external cavity quantum cascade laser , 2010 .

[15]  Frank K. Tittel,et al.  Mid-Infrared Laser Applications in Spectroscopy , 2003 .

[16]  Andreas Becker,et al.  Time-Resolved FT-IR Absorption Spectroscopy Using a Step-Scan Interferometer , 1991 .

[17]  M. Zahniser,et al.  High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors. , 2004, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[18]  A. Goldman,et al.  NITRIC OXIDE LINE PARAMETERS: REVIEW OF 1996 HITRAN UPDATE AND NEW RESULTS , 1998 .

[19]  V. Malathy Devi,et al.  Tunable diode laser spectroscopy of NO2 at 6.2 μm , 1982 .

[20]  W. J. Lafferty,et al.  High-resolution infrared spectrum of the ?3 and ?2 + ?3 - ?2 bands of 14N16O2 , 1976 .

[21]  J. Barry McManus,et al.  Application of quantum cascade lasers to high-precision atmospheric trace gas measurements , 2010 .

[22]  Armin Lambrecht,et al.  Fast gas spectroscopy using pulsed quantum cascade lasers , 2003 .

[23]  Frank K. Tittel,et al.  Widely tunable mode-hop free external cavity quantum cascade laser for high resolution spectroscopic applications , 2005 .

[24]  A A Kosterev,et al.  Trace-gas detection in ambient air with a thermoelectrically cooled, pulsed quantum-cascade distributed feedback laser. , 2000, Applied optics.

[25]  M. Razeghi,et al.  QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL. , 2013, Optics express.

[26]  A G Kjelaas,et al.  Scintillation and multiwavelength coherence effects in a long-path laser absorption spectrometer. , 1978, Applied optics.

[27]  W. Chameides,et al.  A photochemical theory of tropospheric ozone , 1973 .

[28]  P. Macdonald,et al.  Inhaled nitric oxide in cardiology practice. , 1999, Cardiovascular research.

[29]  Geoffrey Duxbury,et al.  Quantum Cascade Semiconductor Infrared and Far‐Infrared Lasers: From Trace Gas Sensing to Non‐Linear Optics , 2006 .

[30]  D. W. Allan,et al.  Statistics of atomic frequency standards , 1966 .

[31]  M. Jahjah,et al.  A sensitive CW DFB quantum cascade laser based QEPAS sensor for detection of SO2 , 2012, 2012 Conference on Lasers and Electro-Optics (CLEO).

[32]  Fred Moshary,et al.  Quantum cascade laser open-path system for remote sensing of trace gases in Beijing, China , 2010 .

[33]  K. Barrington,et al.  Cochrane review: Nitric oxide for respiratory failure in infants born at or near term , 2007 .

[34]  Passage Maximilien-de-Meuron,et al.  Comparison of cw and pulsed operation with a TE-cooled quantum cascade infrared laser for detection of nitric oxide at 1900 cm −1 , 2006 .

[35]  M. Taslakov,et al.  Open-path ozone detection by quantum-cascade laser , 2006 .

[36]  Ronald K. Hanson,et al.  In situ absorption sensor for NO in combustion gases with a 5.2 μm quantum-cascade laser , 2011 .