Gantry angle determination during arc IMRT: evaluation of a simple EPID‐based technique and two commercial inclinometers

The increasing popularity of intensity‐modulated arc therapy (IMAT) treatments requires specifically designed linac quality assurance (QA) programs. Gantry angle is one of the parameters that has a major effect on the outcome of IMAT treatments since dose reconstruction for patient‐specific QA relies on the gantry angle; therefore, it is essential to ensure its accuracy for correct delivery of the prescribed dose. In this study, a simple measurement method and algorithm are presented for QA of gantry angle measurements based on integrated EPID images acquired at distinct gantry angles and cine EPID images during an entire 360° arc. A comprehensive study was carried out to evaluate this method, as well as to evaluate two commercially available inclinometers (NG360 and IBA GAS supplied in conjunction with popular array dosimeters Delta4 and MatriXXEvolution, respectively) by comparing their simultaneous angle measurement results with the linac potentiometer readouts at five gantry speeds. In all tested measurement systems, the average differences with the reference angle data were less than 0.3° in static mode. In arc mode, at all tested gantry speeds the average difference was less than 0.1° for the IBA GAS and the proposed EPID‐based method, and 0.6° for the NG360 after correction for the inherent systematic time delay of the inclinometer. The gantry rotation speed measured by the three independent systems had an average deviation of about 0.01°/s from the nominal gantry speed. PACS numbers: 06.30.Bp; 87.56.Fc; 87.56.‐v

[1]  J. Bedford,et al.  Commissioning of volumetric modulated arc therapy (VMAT). , 2009, International journal of radiation oncology, biology, physics.

[2]  C. Ling,et al.  Commissioning and quality assurance of RapidArc radiotherapy delivery system. , 2008, International journal of radiation oncology, biology, physics.

[3]  Peter B. Greer,et al.  SU‐E‐T‐210: Precise Gantry Angle Determination for EPID Images during Rotational IMRT , 2011 .

[4]  K. Otto,et al.  Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. , 2008, International journal of radiation oncology, biology, physics.

[5]  David Sjostrom,et al.  Implementing RapidArc into clinical routine: a comprehensive program from machine QA to TPS validation and patient QA. , 2011, Medical physics.

[6]  Pejman Rowshanfarzad,et al.  Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries. , 2012, Physics in medicine and biology.

[7]  J. Palta,et al.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. , 1994, Medical physics.

[8]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[9]  Tainsong Chen,et al.  An improved method to accurately calibrate the gantry angle indicators of the radiotherapy linear accelerators , 2007 .

[10]  Peter B. Greer,et al.  1522 poster COMPREHENSIVE VERIFICATION OF THE LINAC ISOCENTRE FOR STEREOTACTIC RADIOSURGERY USING CINE-EPID AND ARC DELIVERY , 2011 .

[11]  Daniel A Low,et al.  Linac mechanic QA using a cylindrical phantom , 2008, Physics in medicine and biology.

[12]  Piotr Zygmanski,et al.  An oscillating sweeping gap test for VMAT quality assurance , 2010, Physics in medicine and biology.

[13]  Peter B. Greer,et al.  An evaluation of cine-mode 3D portal image dosimetry for Volumetric Modulated Arc Therapy , 2010 .

[14]  L Kumaraswamy,et al.  Using an EPID for patient-specific VMAT quality assurance. , 2011, Medical physics.

[15]  Pejman Rowshanfarzad,et al.  Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery. , 2011, Medical physics.

[16]  Pejman Rowshanfarzad,et al.  Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging. , 2012, Medical physics.

[17]  W. Kwa,et al.  Monte Carlo based, patient-specific RapidArc QA using Linac log files. , 2009, Medical physics.

[18]  David A Jaffray,et al.  Accurate technique for complete geometric calibration of cone-beam computed tomography systems. , 2005, Medical physics.

[19]  Liyun Chang,et al.  Technical innovation to calibrate the gantry angle indicators of linear accelerators , 2001, Journal of applied clinical medical physics.

[20]  Jan-Jakob Sonke,et al.  3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  Song Gao,et al.  Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator. , 2011, Medical physics.