Multidimensionally encoded magnetic resonance imaging

Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q‐dimensional object over q‐dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q‐dimensional object onto a p‐dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight‐channel radiofrequency coil array, we demonstrate the five‐dimensional MDE MRI for a two‐dimensional object as a further generalization of PatLoc imaging and O‐space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k‐space sampling distribution and the number of samples are controlled. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.

[1]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[2]  D. Sodickson,et al.  Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations , 2009, Magnetic resonance in medicine.

[3]  J L Ackerman,et al.  Dynamic range compression in MRI by means of a nonlinear gradient pulse , 1988, Magnetic resonance in medicine.

[4]  Maxim Zaitsev,et al.  Simultaneously driven linear and nonlinear spatial encoding fields in MRI , 2011, Magnetic resonance in medicine.

[5]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[6]  S. Mallat A wavelet tour of signal processing , 1998 .

[7]  Yoshifumi Yamada,et al.  NMR Fresnel transform imaging technique using a quadratic nonlinear field gradient , 1992 .

[8]  D. Sodickson,et al.  A generalized approach to parallel magnetic resonance imaging. , 2001, Medical physics.

[9]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[10]  Maxim Zaitsev,et al.  Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields , 2010, Magnetic resonance in medicine.

[11]  Maxim Zaitsev,et al.  Reconstruction of MRI data encoded by multiple nonbijective curvilinear magnetic fields , 2012, Magnetic resonance in medicine.

[12]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[13]  Stéphane Mallat,et al.  A Wavelet Tour of Signal Processing - The Sparse Way, 3rd Edition , 2008 .

[14]  Gigi Galiana,et al.  O‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encoding , 2010, Magnetic resonance in medicine.

[15]  Oliver Speck,et al.  Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.