Resolution of overlapping capillary electrophoresis peaks by using chemometric analysis: Quantification of the components in compound reserpine tablets

The application of multivariate curve resolution with alternating least squares (MCR‐ALS) methods to second‐order data from capillary electrophoresis with diode array detector (CE‐DAD) is reported. Initial qualitative solutions obtained by evolving factor analysis (EFA) and pure‐variable detection method can be further optimized by a simultaneous analysis of multiple electrophoresis run data with ALS regression. While unknown samples are analyzed simultaneously against the corresponding standards in different composition ratios, the exact amounts of common components in different CE runs can be determined by the traditional calibration curve method, and quantification can thus be achieved. The above methods are applied to the determination of the components in compound reserpine tablets in overlapping peaks from CE. The quantification results are compared with those of the first derivative of the electropherogram method and artificial neural network (ANN) method.

[1]  B. Kowalski,et al.  Theory of medium‐rank second‐order calibration with restricted‐Tucker models , 1994 .

[2]  M. Maeder Evolving factor analysis for the resolution of overlapping chromatographic peaks , 1987 .

[3]  Albert Bos,et al.  Tutorial review—Data processing by neural networks in quantitative chemical analysis , 1993 .

[4]  Romà Tauler,et al.  Assessment of new constraints applied to the alternating least squares method , 1997 .

[5]  R. Tauler,et al.  Deconvolution and quantitation of unresolved mixtures in liquid chromatographic-diode array detection using evolving factor analysis , 1992 .

[6]  H. R. Keller,et al.  Heuristic evolving latent projections: resolving two-way multicomponent data. 2. Detection and resolution of minor constituents , 1992 .

[7]  B. Kowalski,et al.  Theory of analytical chemistry , 1994 .

[8]  W. Windig,et al.  Fast self-modeling curve-resolution method for time-resolved mass spectral data , 1988 .

[9]  Edmund R. Malinowski,et al.  Investigation of window factor analysis and matrix regression analysis in chromatography , 1993 .

[10]  Edmund R. Malinowski,et al.  Window factor analysis: Theoretical derivation and application to flow injection analysis data , 1992 .

[11]  Josef Havel,et al.  Artificial neural networks for quantification in unresolved capillary electrophoresis peaks , 2002 .

[12]  R. Manne On the resolution problem in hyphenated chromatography , 1995 .

[13]  A comparison of the heuristic evoling latent projections and evolving factor analysis methods for peak purity control in liquid chromatography with photodiode array detection , 1992 .

[14]  Window evolving factor analysis for assessment of peak homogeneity in liquid chromatography , 1993 .

[15]  B. Kowalski,et al.  Selectivity, local rank, three‐way data analysis and ambiguity in multivariate curve resolution , 1995 .

[16]  Yizeng Liang,et al.  Heuristic evolving latent projections: resolving two-way multicomponent data. 1. Selectivity, latent-projective graph, datascope, local rank, and unique resolution , 1992 .

[17]  Resolution of overlapped peaks of amino acid derivatives in capillary electrophoresis using multivariate curve resolution based on alternating least squares , 2000, Electrophoresis.

[18]  B. Kowalski,et al.  Multivariate curve resolution applied to spectral data from multiple runs of an industrial process , 1993 .

[19]  V. Dohnal,et al.  Quantitative chiral analysis in capillary electrophoresis from unresolved peaks using derivative electropherograms, experimental design, and artificial neural networks , 2003, Electrophoresis.

[20]  V. Dohnal,et al.  Quantitative analysis of chiral compounds from unresolved peaks in capillary electrophoresis using multivariate calibration with experimental design and artificial neural networks. , 2002, Chirality.

[21]  R. Tauler,et al.  Multivariate curve resolution applied to liquid chromatography—diode array detection , 1993 .

[22]  W. Windig Spectral data files for self-modeling curve resolution with examples using the Simplisma approach , 1997 .

[23]  Fang Zhang,et al.  Quantification of analytes in overlapping peaks from capillary electrophoresis using multivariate curve resolution‐alternating least squares methods , 2003, Electrophoresis.

[24]  Romà Tauler,et al.  Comparison of three‐way resolution methods for non‐trilinear chemical data sets , 2001 .

[25]  Desire L. Massart,et al.  Resolution of multicomponent overlapped peaks by the orthogonal projection approach, evolving factor analysis and window factor analysis , 1997 .

[26]  M. Zandomeneghi,et al.  Complexation with albumins of chiral aromatic substrates and their chemistry in ground and excited states. Catalytic and chirality recognition properties of the protein in the cases of binaphthol, its photoisomers, and ketoprofen. , 2002, Chirality.

[27]  S. Sentellas,et al.  Resolution and quantification in poorly separated peaks from capillary zone electrophoresis using three-way data analysis methods , 2001 .

[28]  R. Tauler Multivariate curve resolution applied to second order data , 1995 .

[29]  J. Saurina,et al.  Determination of amino acids in overlapped capillary electrophoresis peaks by means of partial least-squares regression. , 2000, Journal of chromatography. A.

[30]  R. Bro PARAFAC. Tutorial and applications , 1997 .

[31]  Javier Saurina,et al.  Chemometrics in capillary electrophoresis. Part A: Methods for optimization , 2003 .

[32]  W. Windig,et al.  Interactive self-modeling mixture analysis , 1991 .

[33]  Bruce R. Kowalski,et al.  Generalized rank annihilation method , 1987 .

[34]  Multivariate calibration methods for quantification in strongly overlapping capillary electrophoretic peaks. , 2001, Journal of chromatography. A.

[35]  H. Gampp,et al.  Calculation of equilibrium constants from multiwavelength spectroscopic data-III Model-free analysis of spectrophotometric and ESR titrations. , 1985, Talanta.

[36]  Lu Xu,et al.  Quantitative structure-property relationships for colour reagents and their colour reactions with ytterbium using regression analysis and computational neural networks , 1996 .

[37]  Chemometrics in capillary electrophoresis. Part B: Methods for data analysis , 2003 .

[38]  Efficiency of An Automatic Peak Purity Control Procedure in High-performance Liquid-chromatography Photodiode-array Coupling Based On Evolving Factor-analysis , 1993 .

[39]  Age K. Smilde,et al.  Multicomponent Determination of Chlorinated Hydrocarbons Using a Reaction-based Chemical Sensor. Part 2. Chemical Speciation Using Multivariate Curve Resolution , 1994 .