Reactive Power Compensation in AC Power Systems

This chapter introduces most widely used reactive power compensators considering the recent advances seen in industrial applications. In order to provide better and deeper knowledge for authors, the basic principles of reactive power compensation and symmetrical systems are presented primarily. The theoretical backgrounds are discussed by comparing each approach and application types in detail. The remainder of the chapter is organized by considering the comprehensive figure that is illustrated in the third section. Thereby, the first generation conventional compensators and lately improved FACTS are introduced in the following sections. Furthermore, the compensation devices are also listed according to their integration to transmission line as shunt, series, and shunt-series devices. The circuit diagrams and control characteristics of each compensation device are presented with its analytical expressions. The power flow control, voltage and current modifications, and stability issues are illustrated with phasor diagrams in order to create further knowledge on operation principles for each device. The comparisons are associated with similar devices and emerging technologies.

[1]  J. Mescua,et al.  A Decoupled Method for Systematic Adjustments of Phase-Shifting and Tap-Changing Transformers , 1985, IEEE Transactions on Power Apparatus and Systems.

[2]  Heinz K. Tyll,et al.  Historical overview on dynamic reactive power compensation solutions from the begin of AC power transmission towards present applications , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[3]  Ilhami Colak,et al.  Practical implementation of a digital signal processor controlled multilevel inverter with low total , 2011 .

[4]  David Frey,et al.  Application of cascaded H-bridge distribution-static synchronous series compensator in electrical distribution system power flow control , 2012 .

[5]  Bhim Singh,et al.  Three-Level 24-Pulse STATCOM with Pulse Width Control at Fundamental Frequency Switching , 2010, 2010 IEEE Industry Applications Society Annual Meeting.

[6]  Luiz A. C. Lopes,et al.  An efficient switched-reactor-based static VAr compensator , 1994 .

[7]  Mebtu Beza,et al.  Control of Energy Storage Equipped Shunt-connected Converter for Electric Power System Stability Enhancement , 2012 .

[8]  Olimpo Anaya-Lara,et al.  Power electronic equipment , 2002 .

[9]  M. A. Abido,et al.  Development of a new power injection model with embedded multi-control functions for static synchronous series compensator , 2012 .

[10]  R. Mihalic,et al.  Phase-shifting transformer with fixed phase between terminal voltage and voltage boost: tool for transient stability margin enhancement , 1995 .

[11]  Farhad Shahnia,et al.  Static Compensators (STATCOMs) in Power Systems , 2015 .

[12]  Hui Li,et al.  Reactive Power Compensation and Optimization Strategy for Grid-Interactive Cascaded Photovoltaic Systems , 2015, IEEE Transactions on Power Electronics.

[13]  A. K. Chakravorti,et al.  A current regulated switched capacitor static volt ampere reactive compensator , 1994 .

[14]  Pedro G. Barbosa,et al.  Flexible AC Transmission Systems , 2020, CIGRE Green Books.

[15]  Xiao-Ping Zhang,et al.  Advanced modeling of the multicontrol functional static synchronous series compensator (SSSC) in Newton power flow , 2003 .

[16]  R. J. Marceau,et al.  Steady-state analysis of power flow controllers using the power controller plane , 1999 .

[17]  Hortensia Amaris,et al.  Reactive Power Management of Power Networks with Wind Generation , 2012 .

[18]  Byamakesh Nayak,et al.  A Comparative analysis of three level VSC based multi-pulse STATCOM , 2014 .

[19]  Tarlochan S. Sidhu,et al.  A Phase-Shifting Transformer Protection Technique Based on Directional Comparison Approach , 2014, IEEE Transactions on Power Delivery.

[20]  Kalyan K. Sen,et al.  Introduction to Facts Controllers , 2009 .

[21]  C. Rehtanz,et al.  Dynamic Power Flow Controllers for transmission corridors , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[22]  R. Baker,et al.  Control Algorithm for a Static Phase Shifting Transformer to Enhance Transient and Dynamic Stability of Large Power Systems , 1982, IEEE Transactions on Power Apparatus and Systems.

[23]  S. Chatratana,et al.  Analysis of quasi 24-pulse STATCOM operation and control using ATP-EMTP , 2004, 2004 IEEE Region 10 Conference TENCON 2004..

[24]  Laszlo Gyugyi,et al.  Power electronics in electric utilities: static VAR compensators , 1988, Proc. IEEE.

[25]  Ramazan Bayindir,et al.  Review of multilevel voltage source inverter topologies and control schemes , 2011 .

[26]  Bhim Singh,et al.  Three-Level 12-Pulse STATCOM with Constant DC Link Voltage , 2009, 2009 Annual IEEE India Conference.

[27]  Ilhami Colak,et al.  Developing a novel sinusoidal pulse width modulation (SPWM) technique to eliminate side band harmonics , 2013 .

[28]  Rajiv K. Varma,et al.  Thyristor-Based Facts Controllers for Electrical Transmission Systems , 2002 .

[29]  D. Soto,et al.  A comparison of high-power converter topologies for the implementation of FACTS controllers , 2002, IEEE Trans. Ind. Electron..

[30]  Fujio Ishiguro,et al.  Development of a large static VAr generator using self-commutated inverters for improving power system stability , 1991 .

[31]  G. Radman,et al.  Effects of STATCOM, SSSC and UPFC on voltage stability , 2004, Thirty-Sixth Southeastern Symposium on System Theory, 2004. Proceedings of the.

[32]  Kr Padiyar,et al.  Facts Controllers in Power Transmission and Distribution , 2009 .

[33]  V.G. Agelidis,et al.  VSC-Based HVDC Power Transmission Systems: An Overview , 2009, IEEE Transactions on Power Electronics.

[34]  Roya Ahmadi,et al.  Power flow control and solutions with Dynamic Flow Controller , 2008, 2008 IEEE Canada Electric Power Conference.

[35]  U. Hager,et al.  Hardware model of a Dynamic Power Flow Controller , 2011, 2011 IEEE Trondheim PowerTech.

[36]  R. Belmans,et al.  Analytical Approach to Grid Operation With Phase Shifting Transformers , 2008, IEEE Transactions on Power Systems.

[37]  Chung-Neng Huang Feature analysis of power flows based on the allocations of phase shifting transformers , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[38]  A. Prudenzi,et al.  A Model of Large Load Areas for Harmonic Studies in Distribution Networks , 1997, IEEE Power Engineering Review.

[39]  Xiao-Ping Zhang,et al.  Flexible AC Transmission Systems: Modelling and Control , 2006 .

[40]  P.W. Lehn,et al.  Frequency-domain analysis of the static synchronous series compensator , 2006, IEEE Transactions on Power Delivery.

[41]  J. Dixon,et al.  Reactive Power Compensation Technologies: State-of-the-Art Review , 2005, Proceedings of the IEEE.

[42]  Ilhami Colak,et al.  Implementation of Energy-efficient Inverter for Renewable Energy Sources , 2013 .

[43]  Mohsen Farahani Damping of subsynchronous oscillations in power system using static synchronous series compensator , 2012 .

[44]  B. Singh,et al.  A New 24-Pulse STATCOM for Voltage Regulation , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[45]  Ashok Kumar,et al.  Optimal Location for Shunt Connected FACTS Devices in a Series Compensated Long Transmission Line , 2007 .

[46]  Wolfgang Just,et al.  Reactive Power Compensation: A Practical Guide , 2012 .