Performance Evaluation of Bone Mineral Densitometry Techniques by a Novel Phantom

Purpose : Accurate performance assessment of bone mineral density (BMD) methods is crucial due to the fact that a high level of exact estimation of bone situation is needed for correct diagnosis. Variation of parameters like sensitivity and error ratio highly affects the densitometry results that may induce some level of uncertainty in diagnosis. So, designing an algorithm for correction is necessary to assure examiners about measurement results. Methods : In this study several phantoms consisting of soft tissue- and bone-equivalent materials were devised to accurately test bone densitometry systems. To the best of our knowledge there is no unique phantom to be able to use for evaluation of both Dual Energy X-ray Absorptiometry (DEXA) and Quantitative Computed Tomography (QCT) in a wide range of density. The main motivation of this study was to design a reliable and easy to use phantom. A QCT quality control, quality assurance, and Plexiglas cylindrical phantoms as a spine phantom were designed and constructed to assess different bone densities. Four inserts in spine phantom with precisely wide range of K2HPO4 solutions were used for simulation of bone tissues and to determine the BMD systems characteristics. The designed phantoms were also used for performance assessment of BMD systems. We used a sinogram-based analytical CT simulator to model the complete chain of CT data acquisition for QCT method as well. Results : In this research it is demonstrated that by decreasing of bone mineral densities an increasing trend in error ratio of measured densities and declining trend in methods sensitivities were observed in the both DEXA and QCT methods, that may cause some level of uncertainty in low densities. It has been shown that between the ranges of 20 and 100 mg/cc K2HPO4 concentrations, the error ratio in both DEXA and QCT techniques is more than 20%. Sensitivity values in incremental mineral contents ranges between 20- 60 mg/cm 3 and 260-300 mg/cm 3 reveal an upward trend between 0.93 and 1.45 for QCT and from 0.59 to 1.44 for DEXA, respectively. Conclusion : A novel phantom was designed with capability of easily supporting wide range of densities and using in both DEXA and QCT techniques to measure and compare the sensitivity and error of systems. Our phantom showed excellent capability for accurate determination of BMD, particularly in low density bones. In this study it is demonstrated that the sensitivity and error ratio is affected by bone density that may cause uncertain results especially in low densities.

[1]  Thomas G. Maris,et al.  An update on the assessment of osteoporosis using radiologic techniques , 2007, European Radiology.

[2]  C. Cann,et al.  Quantitative CT for determination of bone mineral density: a review. , 1988, Radiology.

[3]  S. Kelder,et al.  Psychosocial, environmental and behavioral factors associated with bone health in middle-school girls. , 2008, Health education research.

[4]  Hamid Soltanian-Zadeh,et al.  Derivation of attenuation map for attenuation correction of PET data in the presence of nanoparticulate contrast agents using spectral CT imaging , 2014, Annals of Nuclear Medicine.

[5]  Klaus Engelke,et al.  Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA). , 2009, Bone.

[6]  Claus Christiansen,et al.  Diagnosis of Osteoporosis , 1992, Southern medical journal.

[7]  S. Cummings,et al.  Monitoring Osteoporosis Therapy With Bone Densitometry: Misleading Changes and Regression to the Mean , 2000 .

[8]  A. Rahmim,et al.  A fast and hardware mimicking analytic CT simulator , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[9]  W. Kalender,et al.  The European Spine Phantom--a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. , 1995, European journal of radiology.

[10]  S. Bonnick Bone Densitometry in Clinical Practice: Application and Interpretation , 2003 .

[11]  H Zaidi,et al.  K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging. , 2013, The British journal of radiology.

[12]  J. Wark,et al.  Measurement of subregional vertebral bone mineral density in vitro using lateral projection dual-energy X-ray absorptiometry: validation with peripheral quantitative computed tomography , 2012, Journal of Bone and Mineral Metabolism.

[13]  D. J. Green,et al.  A Comparison of Phantoms for Cross-Calibration of Lumbar Spine DXA , 2002, Osteoporosis International.

[14]  L. Melton,et al.  Relationship of femoral neck areal bone mineral density to volumetric bone mineral density, bone size, and femoral strength in men and women , 2011, Osteoporosis International.

[15]  H. Genant,et al.  A comparison of spinal quantitative computed tomography with dual energy X-ray absorptiometry in European women with vertebral and nonvertebral fractures , 2001, Calcified Tissue International.