Harmonic linear time invariant modeling of grid-connected parallel inverters-based microgrids

Modern power systems with high penetration of renewable energies, such as wind and photovoltaic (PV), commonly experiment harmonic issues and in some cases this power quality problem leads to instability. To understand and study this phenomenon, small-signal models have been proposed; however, most of these models neglect the harmonic cross-coupling and the harmonics themselves. Consequently, the harmonic interaction among controllers, network elements, loads, and power electronic converters is overlooked. This paper presents two approaches to obtain the small-signal model of a grid-connected AC microgrid constituted by multiple parallel three-phase inverters; one approach is analytical and the another is numerical. The extended harmonic domain (EHD) is used as frame of reference for the proposed small-signal models since it retains the harmonic cross-coupling among all the harmonic components, and transforms a linear periodic time-varying system into a linear time invariant (LTI) system allowing the straightforward use of LTI tools.

[1]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[2]  Stephen J. Wright,et al.  Numerical Optimization , 2018, Fundamental Statistical Inference.

[3]  E. Mollerstedt,et al.  Out of control because of harmonics-an analysis of the harmonic response of an inverter locomotive , 2000, IEEE Control Systems.

[4]  J. Segundo-Ramirez,et al.  Modeling of FACTS Devices Based on SPWM VSCs , 2009, IEEE Transactions on Power Delivery.

[5]  Marta Molinas,et al.  Small-Signal Stability Assessment of Power Electronics Based Power Systems: A Discussion of Impedance- and Eigenvalue-Based Methods , 2017, IEEE Transactions on Industry Applications.

[6]  M.R. Iravani,et al.  Power Management Strategies for a Microgrid With Multiple Distributed Generation Units , 2006, IEEE Transactions on Power Systems.

[7]  Xiongfei Wang,et al.  Harmonic Instability Assessment Using State-Space Modeling and Participation Analysis in Inverter-Fed Power Systems , 2017, IEEE Transactions on Industrial Electronics.

[8]  Jian Sun,et al.  Small-Signal Methods for AC Distributed Power Systems–A Review , 2009, IEEE Transactions on Power Electronics.

[9]  Jon Are Suul,et al.  Frequency-dependent cable modelling for small-signal stability analysis of VSC-HVDC systems , 2016 .

[10]  Dirk Van Hertem,et al.  Mitigation of harmonic interactions by the VSC-HVDC converter in variable networks , 2017 .

[11]  Reza Iravani,et al.  Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications , 2010 .

[12]  Frede Blaabjerg,et al.  Passivity Enhancement in Renewable Energy Source Based Power Plant With Paralleled Grid-Connected VSIs , 2017, IEEE Transactions on Industry Applications.

[13]  Federico Bizzarri,et al.  Steady State Computation and Noise Analysis of Analog Mixed Signal Circuits , 2012, IEEE Transactions on Circuits and Systems I: Regular Papers.

[14]  Norman M. Wereley,et al.  Analysis and control of linear periodically time varying systems , 1990 .

[15]  F. Blaabjerg,et al.  Linearized Modeling Methods of AC–DC Converters for an Accurate Frequency Response , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[16]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[17]  D. Mukhedkar,et al.  Comparative analysis and study of the dynamic stability of AC/DC systems , 1988 .

[18]  Bo Wen,et al.  Influence of phase-locked loop on input admittance of three-phase voltage-source converters , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[19]  Frede Blaabjerg,et al.  A Comprehensive Design Approach of Power Electronic-Based Distributed Generation Units Focused on Power-Quality Improvement , 2017, IEEE Transactions on Power Delivery.

[20]  Babu Narayanan,et al.  Power system stability and control , 2007 .

[21]  A. Medina,et al.  Computation of the Steady-State Solution of Nonlinear Power Systems by Extrapolation to the Limit Cycle Using a Discrete Exponential Expansion Method , 2010 .

[22]  Frede Blaabjerg,et al.  Analysis of phase-locked loop influence on the stability of single-phase grid-connected inverter , 2015, 2015 IEEE 6th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[23]  Christoph Buchhagen,et al.  BorWin1 - First Experiences with harmonic interactions in converter dominated grids , 2016 .

[24]  Enrique Acha,et al.  Dynamic harmonic evolution using the extended harmonic domain , 2003 .

[25]  M. R. Iravani,et al.  Steady-state and dynamic models of unified power flow controller (UPFC) for power system studies , 1996 .

[26]  Frede Blaabjerg,et al.  Analysis of Middle Frequency Resonance in DFIG System Considering Phase-Locked Loop , 2018, IEEE Transactions on Power Electronics.

[27]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[28]  T. Aprille,et al.  Steady-state analysis of nonlinear circuits with periodic inputs , 1972 .

[29]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .

[30]  Frede Blaabjerg,et al.  Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System , 2014, IEEE Transactions on Power Electronics.

[31]  Frede Blaabjerg,et al.  Modeling of VSC-Based Power Systems in the Extended Harmonic Domain , 2017, IEEE Transactions on Power Electronics.

[32]  R. D. Middlebrook,et al.  Input filter considerations in design and application of switching regulators. , 1976 .

[33]  G. W. Chang,et al.  Harmonic Analysis in Frequency and Time Domain , 2013, IEEE Transactions on Power Delivery.