A Low-Frequency Versatile Wireless Power Transfer Technology for Biomedical Implants

Implantable biomedical sensors and actuators are highly desired in modern medicine. In many cases, the implant's electrical power source profoundly determines its overall size and performance. The inductively coupled coil pair operating at the radio-frequency (RF) has been the primary method for wirelessly delivering electrical power to implants for the last three decades. Recent designs significantly improve the power delivery efficiency by optimizing the operating frequency, coil size and coil distance. However, RF radiation hazard and tissue absorption are the concerns in the RF wireless power transfer technology (RF-WPTT) [4], [5]. Also, it requires an accurate impedance matching network that is sensitive to operating environments between the receiving coil and the load for efficient power delivery. In this paper, a novel low-frequency wireless power transfer technology (LF-WPTT) using rotating rare-earth permanent magnets is demonstrated. The LF-WPTT is able to deliver 2.967 W power at ~ 180 Hz to an 117.1 Ω resistor over 1 cm distance with 50% overall efficiency. Because of the low operating frequency, RF radiation hazard and tissue absorption are largely avoided, and the power delivery efficiency from the receiving coil to the load is independent of the operating environment. Also, there is little power loss observed in the LF-WPTT when the receiving coil is enclosed by non-magnetic implant-grade stainless steel.

[1]  O Paiva,et al.  Concept, design and fabrication of smart orthopedic implants. , 2000, Medical engineering & physics.

[2]  Soumyajit Mandal,et al.  Power-Efficient Impedance-Modulation Wireless Data Links for Biomedical Implants , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[3]  R M Nester,et al.  Occupational Safety & Health Administration , 1996, AAOHN journal : official journal of the American Association of Occupational Health Nurses.

[4]  Michael P. Theodoridis,et al.  Distant energy transfer for artificial human implants , 2005, IEEE Transactions on Biomedical Engineering.

[5]  R Bashirullah,et al.  Wireless Implants , 2010, IEEE Microwave Magazine.

[6]  L.S.Y. Wong,et al.  A very low-power CMOS mixed-signal IC for implantable pacemaker applications , 2004, IEEE Journal of Solid-State Circuits.

[7]  Mark A. Wood,et al.  Cardiac Pacemakers From the Patient’s Perspective , 2002 .

[8]  T. Samaras,et al.  The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz , 2006, IEEE Transactions on Microwave Theory and Techniques.

[9]  Leila Parsa,et al.  Design and Implementation of a Direct AC–DC Boost Converter for Low-Voltage Energy Harvesting , 2011, IEEE Transactions on Industrial Electronics.

[10]  Fei Zhang,et al.  Wireless power delivery for wearable sensors and implants in Body Sensor Networks , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[11]  J. David Irwin,et al.  Basic Engineering Circuit Analysis , 1984 .

[12]  Lauri Sydanheimo,et al.  SAR reduction and link optimization for mm-size remotely powered wireless implants using segmented loop antennas , 2011, 2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems.

[13]  Zhong Lin Wang,et al.  Direct-Current Nanogenerator Driven by Ultrasonic Waves , 2007, Science.

[14]  R K Jarvik,et al.  System considerations favoring rotary artificial hearts with blood-immersed bearings. , 1995, Artificial organs.

[15]  Minoru Sanagi,et al.  Development of ultrasonic wireless power transmission system for implantable electronic devices , 2009, 2009 European Wireless Technology Conference.

[16]  Jonathan Liu,et al.  ROBOImplant II: Development of a Noninvasive Controller/Actuator for Wireless Correction of Orthopedic Structural Deformities , 2012 .

[17]  Maysam Ghovanloo,et al.  Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[18]  Maysam Ghovanloo,et al.  An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications , 2011, IEEE Transactions on Circuits and Systems I: Regular Papers.

[19]  Yu-Te Liao,et al.  A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring , 2012, IEEE Journal of Solid-State Circuits.

[20]  Fatimah Ibrahim,et al.  Application of Wireless Power Transmission Systems in Wireless Capsule Endoscopy: An Overview , 2014, Sensors.

[21]  J. Borenstein,et al.  Medicine by micromachine , 2009, IEEE Spectrum.

[22]  Maysam Ghovanloo,et al.  Design and Optimization of Printed Spiral Coils for Efficient Transcutaneous Inductive Power Transmission , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[23]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[24]  Peter M. Asbeck,et al.  An Analytical Model for Inductively Coupled Implantable Biomedical Devices With Ferrite Rods , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[25]  James C. Lin,et al.  Power Deposition in a Spherical Model of Man Exposed to I-20-MHz Electromagnetic Fields , 1973 .

[26]  Maysam Ghovanloo,et al.  Modeling and Optimization of Printed Spiral Coils in Air, Saline, and Muscle Tissue Environments , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[27]  C.M. Zierhofer,et al.  High-efficiency coupling-insensitive transcutaneous power and data transmission via an inductive link , 1990, IEEE Transactions on Biomedical Engineering.

[28]  M. Soljačić,et al.  Wireless Power Transfer via Strongly Coupled Magnetic Resonances , 2007, Science.

[29]  W. Ko,et al.  Design of radio-frequency powered coils for implant instruments , 1977, Medical and Biological Engineering and Computing.

[30]  R.R. Harrison,et al.  A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System , 2006, IEEE Journal of Solid-State Circuits.

[31]  Hao Jiang,et al.  A feed-forward controlled AC-DC boost converter for biomedical implants , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[32]  F. C. Flack,et al.  Mutual inductance of air-cored coils: Effect on design of radio-frequency coupled implants , 1971, Medical and biological engineering.

[33]  Nattapon Chaimanonart,et al.  Two-Channel Passive Data Telemetry With Remote RF Powering for High-Performance Wireless and Batteryless Strain Sensing Microsystem Applications , 2010, IEEE Sensors Journal.

[34]  Hao Jiang,et al.  A high-power versatile wireless power transfer for biomedical implants , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[35]  Anantha Chandrakasan,et al.  An Efficient Piezoelectric Energy Harvesting Interface Circuit Using a Bias-Flip Rectifier and Shared Inductor , 2010, IEEE Journal of Solid-State Circuits.

[36]  N. de N. Donaldson,et al.  Analysis of resonant coupled coils in the design of radio frequency transcutaneous links , 1983, Medical and Biological Engineering and Computing.

[37]  T. Meng,et al.  Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue , 2010, IEEE Transactions on Antennas and Propagation.

[38]  Wentai Liu,et al.  Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.