MRI-based modeling for radiocarpal joint mechanics: validation criteria and results for four specimen-specific models.

The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations. Only the model for one specimen met the validation criteria for average and peak pressure of both articulations; however the experimental measures for peak pressure also exhibited high variability. MRI-based modeling can reliably be used for evaluating the contact area and contact force with similar confidence as in currently available experimental techniques. Average contact pressure, and peak contact pressure were more variable from all measurement techniques, and these measures from MRI-based modeling should be used with some caution.

[1]  T. Mosher,et al.  Cartilage MRI T2 relaxation time mapping: overview and applications. , 2004, Seminars in musculoskeletal radiology.

[2]  F Eckstein,et al.  Knee cartilage of spinal cord-injured patients displays progressive thinning in the absence of normal joint loading and movement. , 2002, Arthritis and rheumatism.

[3]  Chrisman Od,et al.  Experimental arthritis in rabbit knees: a study of relief of pressure on one tibial plateau in immature and mature rabbits. , 1977 .

[4]  Samuel R Ward,et al.  The influence of patella alta on patellofemoral joint stress during normal and fast walking. , 2004, Clinical biomechanics.

[5]  W Herzog,et al.  Joint contact mechanics in the early stages of osteoarthritis. , 2000, Medical engineering & physics.

[6]  Seungbum Koo,et al.  A Framework for the in Vivo Pathomechanics of Osteoarthritis at the Knee , 2004, Annals of Biomedical Engineering.

[7]  D. Wilson,et al.  Accuracy and repeatability of a pressure measurement system in the patellofemoral joint. , 2003, Journal of biomechanics.

[8]  L. Hall,et al.  High resolution MRI relaxation measurements of water in the articular cartilage of the meniscectomized rat knee at 4.7 T. , 2004, Magnetic resonance imaging.

[9]  S F Viegas,et al.  Biomechanics of the wrist. , 1995, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[10]  Gerard A Ateshian,et al.  MRI-based modeling for evaluation of in vivo contact mechanics in the human wrist during active light grasp. , 2007, Journal of biomechanics.

[11]  P. Fowler,et al.  A biomechanical analysis of joint contact forces in the posterior cruciate deficient knee , 2005, Knee Surgery, Sports Traumatology, Arthroscopy.

[12]  Saara M S Totterman,et al.  The use of sequential MR image sets for determining tibiofemoral motion: reliability of coordinate systems and accuracy of motion tracking algorithm. , 2003, Journal of biomechanical engineering.

[13]  Christopher M Powers,et al.  Patellofemoral stress during walking in persons with and without patellofemoral pain. , 2002, Medicine and science in sports and exercise.

[14]  Samuel R Ward,et al.  The Effect of Bracing on Patellofemoral Joint Stress during Free and Fast Walking , 2004, The American journal of sports medicine.

[15]  J Silvennoinen,et al.  T2 relaxation reveals spatial collagen architecture in articular cartilage: A comparative quantitative MRI and polarized light microscopic study , 2001, Magnetic resonance in medicine.

[16]  M. Harris,et al.  An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film. , 1999, Journal of biomechanics.

[17]  E Y Chao,et al.  Effect on force transmission across the carpus in procedures used to treat Kienböck's disease. , 1990, The Journal of hand surgery.

[18]  Heath B. Henninger,et al.  Validation of computational models in biomechanics , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[19]  H Hashizume,et al.  Finite element analysis of pathogenesis of osteoarthritis in the first carpometacarpal joint. , 1995, Acta medica Okayama.

[20]  V. Mlynárik,et al.  Physicochemical Properties of Normal Articular Cartilage and Its MR Appearance , 2000, Investigative radiology.

[21]  M. Nissi,et al.  Comparison of novel clinically applicable methodology for sensitive diagnostics of cartilage degeneration. , 2007, European cells & materials.

[22]  E. Roos,et al.  Positive effects of moderate exercise on glycosaminoglycan content in knee cartilage: a four-month, randomized, controlled trial in patients at risk of osteoarthritis. , 2005, Arthritis and rheumatism.

[23]  Xiang Deng,et al.  Diffusion tensor imaging of native and degenerated human articular cartilage. , 2007, Magnetic resonance imaging.

[24]  Benjamin J Fregly,et al.  Multibody dynamic simulation of knee contact mechanics. , 2004, Medical engineering & physics.

[25]  Yang Xia,et al.  Imaging the physical and morphological properties of a multi‐zone young articular cartilage at microscopic resolution , 2003, Journal of magnetic resonance imaging : JMRI.

[26]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[27]  Thomas R Oxland,et al.  Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine. , 2006, Journal of biomechanics.

[28]  T W Ng,et al.  Inexpensive color evaluation of dye-based pressure-sensitive films for plantar studies. , 2005, Journal of biomechanics.

[29]  S. Delp,et al.  A modeling framework to estimate patellofemoral joint cartilage stress in vivo. , 2005, Medicine and science in sports and exercise.

[30]  K. Kazuki,et al.  Pressure distribution in the radiocarpal joint measured with a densitometer designed for pressure-sensitive film. , 1991, The Journal of hand surgery.

[31]  A. Palmer,et al.  Biomechanics of the distal radioulnar joint. , 1984, Clinical orthopaedics and related research.

[32]  Hall Mc Cartilage changes after experimental relief of contact in the knee joint of the mature rat. , 1969 .

[33]  M S Laasanen,et al.  T(2) relaxation time mapping reveals age- and species-related diversity of collagen network architecture in articular cartilage. , 2006, Osteoarthritis and cartilage.

[34]  G. Ateshian,et al.  PRELIMINARY VALIDATION OF MRI-BASED MODELING FOR EVALUATION OF JOINT MECHANICS , 2008 .

[35]  S. D. Kwak,et al.  A Mathematical Formulation for 3D Quasi-Static Multibody Models of Diarthrodial Joints , 2000, Computer methods in biomechanics and biomedical engineering.

[36]  S L Woo,et al.  A validated three-dimensional computational model of a human knee joint. , 1999, Journal of biomechanical engineering.

[37]  R. L. Linscheid,et al.  Force distribution across wrist joint: application of pressure-sensitive conductive rubber. , 1992, The Journal of hand surgery.