Correlation between the behavior of magnetic iron oxide particles in the lungs of rabbits and phagocytosis.

Five New Zealand white male rabbits were exposed (30 min; 300 mg/m3) to a submicrometric magnetic iron oxide aerosol (gamma-Fe2O3) produced by burning iron pentacarbonyl in a reducing atmosphere. After aerosol inhalation, an external magnetic field was applied to the rabbits to magnetize and align the ferrimagnetic particles within their lungs. After removal of the external field, a remanent magnetic field was detectable at the body surface. Using a flux-gate magnetometer probe in an enclosure shielded against external magnetic noise, the peak remanent field after magnetization was measured periodically during the next 6 weeks. After each magnetization, the strength of the remanent field decayed rapidly with time (relaxation). The mechanism responsible is particle rotation caused by tissue, cell, organelle, or Brownian movement. The rate of relaxation changed with time after particle inhalation, especially during the first day; changes in the relaxation rate correlated with an estimate of in situ particle phagocytosis during that time. Analysis of pulmonary lavage fluid from 15 rabbits into which radioactive gold-198 had been intratracheally instilled showed that, at 1 hr after instillation, 27% of the gold had been phagocytized, whereas at 16 hr 91% had been ingested. The strength of the magnetic field immediately after each magnetization (that is, before relaxation) was used to estimate the amount of iron oxide in the lungs. At 1 day after exposure, 96.8 +/- 8.8% (mean +/- standard error) of the initial dust was still present; at 10 days, 67.9 +/- 16.2%; and at 40 days, 16.0 +/- 4.6%. It is concluded that ferrimagnetic particles can serve as an easily measured, long-lasting marker that can be used for noninvasive studies of clearance and of particle phagocytosis and as a probe for intracellular processes such as organelle motion.

[1]  Donald Hunter,et al.  The diseases of occupations , 2006 .

[2]  J. Brain,et al.  The effect of increased particles on the endocytosis of radiocolloids by pulmonary macrophages in vivo: competitive and toxic effects. , 1975, Inhaled particles.

[3]  P. Valberg,et al.  An iron oxide aerosol suitable for animal exposures , 1974 .

[4]  L. Stettler,et al.  Identification of stainless steel welding fume particulates in human lung and environmental samples using electron probe microanalysis. , 1977, American Industrial Hygiene Association journal.

[5]  J. Brain,et al.  Smoking impairs long-term dust clearance from the lung. , 1979, Science.

[6]  Peter Gehr,et al.  Magnetic particles in the liver: a probe for intracellular movement , 1983, Nature.

[7]  V. Massey,et al.  [73] Determination of nonheme iron, total iron, and copper , 1967 .

[8]  W. Hinds Size characteristics of cigarette smoke. , 1978, American Industrial Hygiene Association journal.

[9]  J. Brain,et al.  Pathways of clearance in mouse lungs exposed to iron oxide aerosols , 1975, The Anatomical record.

[10]  A Tossavainen,et al.  Magnetic measurements of pulmonary contamination. , 1976, Scandinavian journal of work, environment & health.

[11]  P. Morrow,et al.  Effect of Freund's complete adjuvant upon clearance of iron-59 oxide from rat lungs. , 1973, Journal of the Reticuloendothelial Society.

[12]  S. Williamson,et al.  Remanent magnetic fields for measuring particle retention and distribution in the lungs. , 1981, Experimental lung research.

[13]  B. Ferris,et al.  Pulmonary Function in Shipyard Welders , 1973 .

[14]  P. Valberg,et al.  Generation and use of three types of iron-oxide aerosol. , 1979, The American review of respiratory disease.

[15]  M. Tillery A concentric aerosol spectrometer. , 1974, American Industrial Hygiene Association Journal.

[16]  R. Frank,et al.  Alveolar macrophage adhesion: wash electrolyte composition and free cell yield. , 1973, Journal of applied physiology.

[17]  R. Kavet,et al.  Phagocytosis: quantification of rates and intercellular heterogeneity. , 1977, Journal of applied physiology: respiratory, environmental and exercise physiology.

[18]  D. Cohen,et al.  Ferromagnetic Contamination in the Lungs and Other Organs of the Human Body , 1973, Science.

[19]  P. Morrow,et al.  Alveolar clearance in dogs after inhalation of an iron 59 oxide aerosol. , 1962, Journal of applied physiology.

[20]  R. Kavet,et al.  Characteristics of pulmonary macrophages lavaged from hamsters exposed to iron oxide aerosols. , 1978, Laboratory investigation; a journal of technical methods and pathology.

[21]  P. Gehr,et al.  Behavior of magnetic particles in hamster lungs: estimates of clearance and cytoplasmic motility. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.