Chirp optical coherence tomography of layered scattering media.

A new noninvasive technique that reveals cross sectional images of scattering media is presented. It is based on a continuous wave frequency modulated radar, but uses a tunable laser in the near infrared. As the full width at half maximum resolution of 16 μm is demonstrated with an external cavity laser, the chirp optical coherence tomography becomes an alternative to conventional short coherence tomography with the advantage of a simplified optical setup. The analysis of two-layer solid phantoms shows that the backscattered light gets stronger with decreasing anisotropic factor and increasing scattering coefficient, as predicted by Monte Carlo simulations. By introducing a two-phase chirp sequence, the combination of lateral resolved perfusion and depth resolved structure is shown. © 1998 Society of Photo-Optical Instrumentation Engineers.

[1]  E Reichel,et al.  Characterization of epiretinal membranes using optical coherence tomography. , 1996, Ophthalmology.

[2]  J. Schmitt,et al.  Confocal microscopy in turbid media. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  S. A. Prahl,et al.  A Monte Carlo model of light propagation in tissue , 1989, Other Conferences.

[4]  N. Gisin,et al.  High-sensitivity-coherent optical frequency-domain reflectometry for characterization of fiber-optic network components , 1995, IEEE Photonics Technology Letters.

[5]  E. Brinkmeyer,et al.  Coherent frequency-domain reflectometry for characterization of single-mode integrated-optical waveguides , 1993 .

[6]  Peter Jansen,et al.  Optical coherence tomography of scattering media using frequency-modulated continuous-wave techniques with tunable near-infrared laser , 1997, Photonics West - Biomedical Optics.

[7]  Vladimir Blazek,et al.  Investigation of highly scattering media using near-infrared continuous wave tunable semiconductor laser , 1995, Photonics West.

[8]  E. Brinkmeyer,et al.  Modified optical frequency domain reflectometry with high spatial resolution for components of integrated optic systems , 1989 .

[9]  Harald Sattmann,et al.  Measurement of the thickness of fundus layers by partial coherence tomography , 1995 .

[10]  D. Delpy,et al.  A design for a stable and reproducible phantom for use in near infra-red imaging and spectroscopy , 1993 .

[11]  Gert E. Nilsson,et al.  A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy , 1980, IEEE Transactions on Biomedical Engineering.