Identification of Rotors during Human Atrial Fibrillation Using Contact Mapping and Phase Singularity Detection: Technical Considerations

Objective: To explore technical challenges of phase singularity (PS) mapping during atrial fibrillation (AF) using direct contact electrograms. Methods: AF mapping was performed in high-density epicardial recordings of human paroxysmal (PAF) or persistent (PersAF) (N = 20 pts) AF with an array of 16 × 16 electrodes placed on atrial epicardium. PS points were detected using subsets of electrodes forming rings of varying sizes. Results: PS detection using a 2 × 2 electrode ring identified 0.88 ± 1.00 PS/s in PAF group and 3.91 ± 2.51 per s in PersAF group (p < 0.001) in 2.4 × 2.4 cm mapping area. All detected PS had a short lifespan with the longest being 1100 ms (6.8 rotations). Exploration of the PS detection in a numerical model demonstrated that at least eight electrodes are required to avoid frequent false positive PS detection due to chance. Application of a detection grid consisting a double ring of electrodes (2 × 2 and 4 × 4 rings) decreased the number of false positive detections. The double ring was more resilient to electrode swapping (with just three instances of false positives versus 4380 false positives using 2 × 2 ring). Conclusions: The number of detected rotors critically depends upon the parameters of the detection algorithm, especially the number of electrodes used to detect PS. Based on our results, we recommend double ring comprised of 2 × 2 and 4 × 4 grid of electrodes for robust rotor detection. Significance: Great methodological care has to be taken before equating detected PS with rotating waves and using PS detection algorithms to guide catheter ablation of AF.

[1]  Ulrich Schotten,et al.  Electropathological Substrate of Long-Standing Persistent Atrial Fibrillation in Patients With Structural Heart Disease: Longitudinal Dissociation , 2010, Circulation. Arrhythmia and electrophysiology.

[2]  Ichiro Sakuma,et al.  Detection Algorithm of Phase Singularity Using Phase Variance Analysis for Epicardial Optical Mapping Data , 2016, IEEE Transactions on Biomedical Engineering.

[3]  Pawel Kuklik,et al.  Reconstruction of Instantaneous Phase of Unipolar Atrial Contact Electrogram Using a Concept of Sinusoidal Recomposition and Hilbert Transform , 2015, IEEE Transactions on Biomedical Engineering.

[4]  José Jalife,et al.  Rotors and Spiral Waves in Atrial Fibrillation , 2003, Journal of cardiovascular electrophysiology.

[5]  Omer Berenfeld,et al.  Ectopic and reentrant activation patterns in the posterior left atrium during stretch-related atrial fibrillation. , 2012, Progress in biophysics and molecular biology.

[6]  Stef Zeemering,et al.  Automated quantification of atrial fibrillation complexity by probabilistic electrogram analysis and fibrillation wave reconstruction , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Sanjiv M. Narayan,et al.  Panoramic Electrophysiological Mapping but not Electrogram Morphology Identifies Stable Sources for Human Atrial Fibrillation: Stable Atrial Fibrillation Rotors and Focal Sources Relate Poorly to Fractionated Electrograms , 2013, Circulation. Arrhythmia and electrophysiology.

[8]  Kalyanam Shivkumar,et al.  Quantitative Analysis of Localized Sources Identified by Focal Impulse and Rotor Modulation Mapping in Atrial Fibrillation , 2015, Circulation. Arrhythmia and electrophysiology.

[9]  Geoffrey Lee,et al.  The effect of electrode density on the interpretation of atrial activation patterns in epicardial mapping of human persistent atrial fibrillation. , 2016, Heart rhythm.

[10]  N. D. Mermin,et al.  The topological theory of defects in ordered media , 1979 .

[11]  Shibaji Shome,et al.  Practical Considerations of Mapping Persistent Atrial Fibrillation With Whole-Chamber Basket Catheters. , 2016, JACC. Clinical electrophysiology.

[12]  Prashanthan Sanders,et al.  Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity. , 2014, European heart journal.

[13]  Sanjiv M Narayan,et al.  Stability of Rotors and Focal Sources for Human Atrial Fibrillation: Focal Impulse and Rotor Mapping (FIRM) of AF Sources and Fibrillatory Conduction , 2014, Journal of cardiovascular electrophysiology.

[14]  Wouter-Jan Rappel,et al.  Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial. , 2012, Journal of the American College of Cardiology.

[15]  P. Kirchhof,et al.  Pathophysiological mechanisms of atrial fibrillation: a translational appraisal. , 2011, Physiological reviews.

[16]  M. Allessie,et al.  High-density mapping of electrically induced atrial fibrillation in humans. , 1994, Circulation.

[17]  Kalyanam Shivkumar,et al.  Long-term clinical outcomes of focal impulse and rotor modulation for treatment of atrial fibrillation: A multicenter experience. , 2016, Heart rhythm.

[18]  Kumaraswamy Nanthakumar,et al.  Optical mapping of Langendorff-perfused human hearts: establishing a model for the study of ventricular fibrillation in humans. , 2007, American journal of physiology. Heart and circulatory physiology.

[19]  Ulrich Schotten,et al.  Fibrillatory Conduction in the Atrial Free Walls of Goats in Persistent and Permanent Atrial Fibrillation , 2010, Circulation. Arrhythmia and electrophysiology.

[20]  Kumaraswamy Nanthakumar,et al.  Phase Mapping of Cardiac Fibrillation , 2010, Circulation. Arrhythmia and electrophysiology.

[21]  W. Rappel,et al.  Computational Mapping Identifies Localized Mechanisms for Ablation of Atrial Fibrillation , 2012, PloS one.

[22]  Sanjiv M Narayan,et al.  Direct or coincidental elimination of stable rotors or focal sources may explain successful atrial fibrillation ablation: on-treatment analysis of the CONFIRM trial (Conventional ablation for AF with or without focal impulse and rotor modulation). , 2013, Journal of the American College of Cardiology.

[23]  B. Roth,et al.  Experimental and Theoretical Analysis of Phase Singularity Dynamics in Cardiac Tissue , 2001, Journal of cardiovascular electrophysiology.

[24]  L. Joshua Leon,et al.  Development of a computer algorithm for the detection of phase singularities and initial application to analyze simulations of atrial fibrillation. , 2002, Chaos.

[25]  Jichao Zhao,et al.  Atrial fibrillation driven by micro-anatomic intramural re-entry revealed by simultaneous sub-epicardial and sub-endocardial optical mapping in explanted human hearts. , 2015, European heart journal.

[26]  J Jalife,et al.  Dynamics of wavelets and their role in atrial fibrillation in the isolated sheep heart. , 2000, Cardiovascular research.

[27]  Martyn P. Nash,et al.  Evidence for Multiple Mechanisms in Human Ventricular Fibrillation , 2006, Circulation.

[28]  Sanjiv M Narayan,et al.  Ablation of rotor and focal sources reduces late recurrence of atrial fibrillation compared with trigger ablation alone: extended follow-up of the CONFIRM trial (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation). , 2014, Journal of the American College of Cardiology.