On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI

The increasing use of multiple radiofrequency (RF) transmit channels in magnetic resonance imaging (MRI) systems makes it necessary to rigorously assess the risk of RF-induced heating. This risk is especially aggravated with inclusions of medical implants within the body. The worst-case RF-heating scenario is achieved when the local tissue deposition in the at-risk region (generally in the vicinity of the implant electrodes) reaches its maximum value while MRI exposure is compliant with predefined general specific absorption rate (SAR) limits or power requirements. This work first reviews the common approach to estimate the worst-case RF-induced heating in multi-channel MRI environment, based on the maximization of the ratio of two Hermitian forms by solving a generalized eigenvalue problem. It is then shown that the common approach is not rigorous and may lead to an underestimation of the worst-case RF-heating scenario when there is a large number of RF transmit channels and there exist multiple SAR or power constraints to be satisfied. Finally, this work derives a rigorous SAR-based formulation to estimate a preferable worst-case scenario, which is solved by casting a semidefinite programming relaxation of this original non-convex problem, whose solution closely approximates the true worst-case including all SAR constraints. Numerical results for 2, 4, 8, 16, and 32 RF channels in a 3T-MRI volume coil for a patient with a deep-brain stimulator under a head imaging exposure are provided as illustrative examples.

[1]  F. R. Gantmakher The Theory of Matrices , 1984 .

[2]  Niels Kuster,et al.  Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners , 2013, Bioelectromagnetics.

[3]  Niels Kuster,et al.  Safety assessment of AIMDs under MRI exposure: Tier3 vs. Tier4 evaluation of local RF-induced heating , 2014, 2014 International Symposium on Electromagnetic Compatibility, Tokyo.

[4]  Tamás Terlaky,et al.  On maximization of quadratic form over intersection of ellipsoids with common center , 1999, Math. Program..

[5]  R. Rockafellar Convex Analysis: (pms-28) , 1970 .

[6]  Niels Kuster,et al.  Virtual population‐based assessment of the impact of 3 Tesla radiofrequency shimming and thermoregulation on safety and B1+ uniformity , 2016, Magnetic resonance in medicine.

[7]  C. Eckart,et al.  The approximation of one matrix by another of lower rank , 1936 .

[8]  Zhi-Quan Luo,et al.  Semidefinite Relaxation of Quadratic Optimization Problems , 2010, IEEE Signal Processing Magazine.

[9]  Peter Börnert,et al.  A specific absorption rate prediction concept for parallel transmission MR , 2012, Magnetic resonance in medicine.

[10]  Anthony Man-Cho So,et al.  On approximating complex quadratic optimization problems via semidefinite programming relaxations , 2005, IPCO.

[11]  Kim-Chuan Toh,et al.  Solving semidefinite-quadratic-linear programs using SDPT3 , 2003, Math. Program..

[12]  Sung-Min Park,et al.  Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer function , 2007, Journal of magnetic resonance imaging : JMRI.

[13]  N. Kuster,et al.  Assessment of local RF-induced heating of AIMDs during MR exposure , 2014, 2014 XXXIth URSI General Assembly and Scientific Symposium (URSI GASS).

[14]  Carl D. Meyer,et al.  Matrix Analysis and Applied Linear Algebra , 2000 .

[15]  M. Lazebnik,et al.  Safe magnetic resonance imaging scanning of patients with cardiac rhythm devices: a role for computer modeling. , 2013, Heart rhythm.

[16]  Stephen P. Boyd,et al.  Graph Implementations for Nonsmooth Convex Programs , 2008, Recent Advances in Learning and Control.

[17]  Kim-Chuan Toh,et al.  SDPT3 -- A Matlab Software Package for Semidefinite Programming , 1996 .

[18]  Lawrence L. Wald,et al.  Parallel transmit pulse design for patients with deep brain stimulation implants , 2015, Magnetic resonance in medicine.

[19]  Niels Kuster,et al.  Convex optimization of MRI exposure for mitigation of RF-heating from active medical implants , 2015, Physics in medicine and biology.

[20]  Olaf Dössel,et al.  Local SAR management by RF Shimming: a simulation study with multiple human body models , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[21]  Niels Kuster,et al.  Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0 , 2014, Physics in medicine and biology.

[22]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[23]  Niels Kuster,et al.  Analysis of the local worst-case SAR exposure caused by an MRI multi-transmit body coil in anatomical models of the human body , 2011, Physics in medicine and biology.

[24]  Niels Kuster,et al.  Piece-wise excitation system for the characterization of local RF-induced heating of AIMD during MR exposure , 2014, 2014 International Symposium on Electromagnetic Compatibility, Tokyo.