Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.

Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the radius of the curvature of a bearing surface and consequently improving the conformity between the head and the cup. In this study, a novel metal-on-metal hip implant employing a specific aspherical bearing surface, Alpharabola, as the acetabular surface was investigated for both contact mechanics and elastohydrodynamic lubrication under steady-state conditions. When compared with conventional spherical bearing surfaces, a more uniform pressure distribution and a thicker lubricant film thickness within the loaded conjunction were predicted for this novel Alpharabola hip implant. The effects of the geometric parameters of this novel acetabular surface on the pressure distribution and lubricant thickness were investigated. A significant increase in the predicted lubricant film thickness and a significant decrease in the dry contact and hydrodynamic pressures were found with appropriate combinations of these geometric parameters, compared with the spherical bearing surface.

[1]  Z. Jin,et al.  Deformation of press-fitted metallic resurfacing cups. Part 2: Finite element simulation , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  Z. Jin,et al.  Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  N. Baldini,et al.  Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. , 2002, Journal of biomedical materials research.

[4]  Zhongmin Jin,et al.  Importance of Head Diameter, Clearance, and Cup Wall Thickness in Elastohydrodynamic Lubrication Analysis of Metal-On-Metal Hip Resurfacing Prostheses , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  Theoretical studies of elastohydrodynamic lubrication of artificial hip joints , 2006 .

[6]  D. Dowson Tribological principles in metal-on-metal hip joint design , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[7]  Duncan Dowson,et al.  The lubrication of metal-on-metal total hip joints: A slide down the Stribeck curve , 2001 .

[8]  H S Dobbs,et al.  Metal ion release after total hip replacement. , 1980, Biomaterials.

[9]  J Fisher,et al.  Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. , 2001, Bio-medical materials and engineering.

[10]  P. Campbell,et al.  Tissue Reaction to Metal on Metal Total Hip Prostheses , 1996, Clinical orthopaedics and related research.

[11]  Z. Jin,et al.  A general elastohydrodynamic lubrication analysis of artificial hip joints employing a compliant layered socket under steady state rotation , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  J. Medley,et al.  Numerical Analysis of Time-Varying Fluid Film Thickness in Metal-Metal Hip Implants in Simulator Tests , 1998 .

[13]  John Fisher,et al.  Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation , 2007, Journal of materials science. Materials in medicine.

[14]  Z. Jin,et al.  Elastohydrodynamic Lubrication Modeling of Artificial Hip Joints Under Steady-State Conditions , 2005 .

[15]  P. Campbell,et al.  Serum and urine metal levels in patients with metal-on-metal surface arthroplasty , 2002, Journal of materials science. Materials in medicine.

[16]  Z. Jin,et al.  Contact mechanics of a novel metal-on-metal total hip replacement , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  P. Campbell,et al.  Cobalt and Chromium Concentrations in Patients With Metal on Metal Total Hip Replacements , 1996, Clinical orthopaedics and related research.

[18]  Roy D. Crowninshield,et al.  The influences of lubricant and material on polymer/CoCr sliding friction , 2003 .

[19]  John B Medley,et al.  Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[20]  Duncan Dowson,et al.  The Rheology of Synovial Fluid and Some Potential Synthetic Lubricants for Degenerate Synovial Joints , 1978 .

[21]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[22]  T. Schmalzried,et al.  The risk of cancer following total hip or knee arthroplasty. , 2001, The Journal of bone and joint surgery. American volume.

[23]  E. Chassot,et al.  Contamination by metallic elements released from joint prostheses. , 2004, Medical engineering & physics.

[24]  F. C. Wang,et al.  Prediction of elastic deformation of acetabular cups and femoral heads for lubrication analysis of artificial hip joints , 2004 .

[25]  Z. Jin,et al.  Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[26]  D. Dowson,et al.  A study of the effect of model geometry and lubricant rheology upon the elastohydrodynamic lubrication performance of metal-on-metal hip joints , 2008 .

[27]  C. Rieker,et al.  Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants. , 2005, The Orthopedic clinics of North America.

[28]  M. Tuke,et al.  Design considerations and life prediction of metal-on-metal bearings: the effect of clearance. , 2008, The Journal of bone and joint surgery. American volume.

[29]  J. Jacobs,et al.  Metal sensitivity in patients with orthopaedic implants. , 2001, The Journal of bone and joint surgery. American volume.

[30]  Z. Jin,et al.  Analysis of elastohydrodynamic lubrication in a novel metal-on-metal hip joint replacement , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[31]  Duncan Dowson,et al.  A hip joint simulator study of the performance of metal-on-metal joints: Part II: design. , 2004, The Journal of arthroplasty.

[32]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[33]  Effect of non-spherical bearing geometry on transient elastohydrodynamic lubrication in metal-on-metal hip joint implants , 2007 .

[34]  Leiming Gao,et al.  Comparison of numerical methods for elastohydrodynamic lubrication analysis of metal-on-metal hip implants: Multi-grid verses Newton-Raphson , 2007 .

[35]  M M Morlock,et al.  Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[36]  A. Essner,et al.  Tribological considerations in primary and revision metal-on-metal arthroplasty. , 2008, The Journal of bone and joint surgery. American volume.

[37]  P Roberts,et al.  Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions. , 2006, Journal of biomechanics.