Mass sensing with resonating ultra-thin silicon beams detected by a double-beam laser Doppler vibrometer

This paper reports on mass sensing with 33 nm thick single-crystalline cantilevers by a double-beam laser Doppler vibrometer. The resonant frequency of an oscillating thin cantilever beam is very sensitive to a loaded mass. However, the drift of the resonance, due to gas adsorption and mechanical instability, limits the minimum detectable mass in general. Two cantilevers for sensing and its reference will compensate their influences. Two cantilevers were made to self-oscillate by electrostatic actuation at different resonant frequencies. A 10 pg sample (a particle of organosilicon monomer) was mounted at the end of one cantilever, and thermogravimetry of the sample using the two cantilevers was demonstrated. The cantilevers were heated up by a heater in vacuum, and the change in mass was detected from the change in resonant frequency. The exact temperature change can be estimated from the change in resonant frequency of one cantilever as a reference. The derivative of the frequency change, corresponding to desorbed mass, clearly shows a peak of mass desorption at about 270 °C.

[1]  Michael L. Roukes,et al.  Intrinsic dissipation in high-frequency micromechanical resonators , 2002 .

[2]  J. Vig,et al.  Noise in microelectromechanical system resonators , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Anja Boisen,et al.  A microcantilever-based alcohol vapor sensor-application and response model , 2000 .

[4]  M. Esashi,et al.  Energy dissipation in submicrometer thick single-crystal silicon cantilevers , 2002 .

[5]  M. Esashi,et al.  Mechanical behavior of ultrathin microcantilever , 2000 .

[6]  Thomas P. Burg,et al.  Suspended microchannel resonators for biomolecular detection , 2003 .

[7]  H. Craighead,et al.  Mechanical resonant immunospecific biological detector , 2000 .

[8]  M. Esashi,et al.  Resonance enhancement of micromachined resonators with strong mechanical-coupling between two degrees of freedom , 2003 .

[9]  Panos G. Datskos,et al.  Femtogram mass detection using photothermally actuated nanomechanical resonators , 2003 .

[10]  Vinayak P. Dravid,et al.  Microcantilever resonance-based DNA detection with nanoparticle probes , 2003 .

[11]  Decrease of the resonance bandwidth of micromechanical oscillators by phase control of the driving force , 2003 .

[12]  Wenhua Zhang,et al.  Effect of cubic nonlinearity on auto-parametrically amplified resonant MEMS mass sensor , 2002 .

[13]  Ernst Meyer,et al.  Nanomechanics from atomic resolution to molecular recognition based on atomic force microscopy technology , 2002 .

[14]  Masayoshi Esashi,et al.  Time dependence of energy dissipation in resonating silicon cantilevers in ultrahigh vacuum , 2003 .

[15]  Jaume Esteve,et al.  Monolithic integration of mass sensing nano-cantilevers with CMOS circuitry , 2003 .

[16]  Masayoshi Esashi,et al.  Mass sensing of adsorbed molecules in sub-picogram sample with ultrathin silicon resonator , 2003 .

[17]  Panos G. Datskos,et al.  Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers , 1999 .

[18]  Masayoshi Esashi,et al.  Surface effects and high quality factors in ultrathin single-crystal silicon cantilevers , 2000 .

[19]  D. Rugar,et al.  Frequency modulation detection using high‐Q cantilevers for enhanced force microscope sensitivity , 1991 .

[20]  Peter Vettiger,et al.  Sequential position readout from arrays of micromechanical cantilever sensors , 1998 .

[21]  Jian Zhang,et al.  Quartz tuning fork biosensor. , 2002, Biosensors & bioelectronics.

[22]  Thomas Thundat,et al.  Micromechanical radiation dosimeter , 1995 .