Crystal Identification in Dual-Layer-Offset DOI-PET Detectors Using Stratified Peak Tracking Based on SVD and Mean-Shift Algorithm

An Anger-logic based pixelated PET detector block requires a crystal position map (CPM) to assign the position of each detected event to a most probable crystal index. Accurate assignments are crucial to PET imaging performance. In this paper, we present a novel automatic approach to generate the CPMs for dual-layer offset (DLO) PET detectors using a stratified peak tracking method. In which, the top and bottom layers are distinguished by their intensity difference and the peaks of the top and bottom layers are tracked based on a singular value decomposition (SVD) and mean-shift algorithm in succession. The CPM is created by classifying each pixel to its nearest peak and assigning the pixel with the crystal index of that peak. A Matlab-based graphical user interface program was developed including the automatic algorithm and a manual interaction procedure. The algorithm was tested for three DLO PET detector blocks. Results show that the proposed method exhibits good performance as well as robustness for all the three blocks. Compared to the existing methods, our approach can directly distinguish the layer and crystal indices using the information of intensity and offset grid pattern.

[1]  Tianyu Ma,et al.  A neighborhood standard deviation based algorithm for generating PET crystal position maps , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[2]  Zhi Deng,et al.  Development of a 64-Channel Readout ASIC for an ${8 \times 8}$ SSPM Array for PET and TOF-PET Applications , 2016, IEEE Transactions on Nuclear Science.

[3]  R.M. Leahy,et al.  Spatial Distortion Correction and Crystal Identification for MRI-Compatible Position-Sensitive Avalanche Photodiode-Based PET Scanners , 2009, IEEE Transactions on Nuclear Science.

[4]  B.E. Atkins,et al.  A Neural Network Based Algorithm for Building Crystal Look-up Table of PET Block Detector , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[5]  K.A. Stonger,et al.  Optimal calibration of PET Crystal position maps using Gaussian mixture models , 2004, IEEE Transactions on Nuclear Science.

[6]  Qingyang Wei,et al.  Measure PET detector performance with the intrinsic radioactivity of scintillator , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[7]  K. Kamada,et al.  Development of a Dual-Sided Readout DOI-PET Module Using Large-Area Monolithic MPPC-Arrays , 2013, IEEE Transactions on Nuclear Science.

[8]  S. Cherry,et al.  Application of Silicon Photomultipliers to Positron Emission Tomography , 2011, Annals of Biomedical Engineering.

[9]  Tianyu Ma,et al.  Development of an MR-compatible DOI-PET detector module , 2015, EJNMMI Physics.

[10]  Piotr Kozlowski,et al.  Development and evaluation of a LOR-based image reconstruction with 3D system response modeling for a PET insert with dual-layer offset crystal design , 2013, Physics in medicine and biology.

[11]  Xinyi Cheng,et al.  Self-Organizing Map Neural Network-Based Nearest Neighbor Position Estimation Scheme for Continuous Crystal PET Detectors , 2014, IEEE Transactions on Nuclear Science.

[12]  Jae Sung Lee,et al.  Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET Scanner , 2012, The Journal of Nuclear Medicine.

[13]  H. Murayama,et al.  Calibration procedure for a DOI detector of high resolution PET through a Gaussian mixture model , 2004, IEEE Transactions on Nuclear Science.

[14]  Wang Shi,et al.  Influence factors of two dimensional position map on photomultiplier detector block designed by quadrant sharing technique , 2011 .

[15]  Eric Berg,et al.  Comparison of single and dual layer detector blocks for pre-clinical MRI-PET , 2013 .

[16]  Anand A. Joshi,et al.  Crystal identification in positron emission tomography using nonrigid registration to a Fourier-based template , 2008, Physics in medicine and biology.

[17]  K. Wienhard,et al.  PCA-Based Algorithm for Generation of Crystal Lookup Tables for PET Block Detectors , 2009, IEEE Transactions on Nuclear Science.

[18]  Yizong Cheng,et al.  Mean Shift, Mode Seeking, and Clustering , 1995, IEEE Trans. Pattern Anal. Mach. Intell..

[19]  Klaus Wienhard,et al.  The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000 .

[20]  R. Lecomte,et al.  Properties of LYSO and recent LSO scintillators for phoswich PET detectors , 2004, IEEE Transactions on Nuclear Science.

[21]  Tianyu Ma,et al.  Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications , 2015 .

[22]  Nan Zhang,et al.  Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectors , 2002 .

[23]  David B. Keator,et al.  Crystal Identification in Positron Emission Tomography Using Probabilistic Graphical Models , 2015, IEEE Transactions on Nuclear Science.