Reliability Evaluation of Smart Meters Under Degradation-Shock Loads Based on Phase-Type Distributions

To address the problem that high-reliability and long-life complex products are susceptible to coupled fault mechanisms, and to address the challenge of constructing a macro fault behavior model for reliability evaluation, the reliability of a smart meter based on a Phase-Type (PH) distribution under a degradation-shock load is examined. This reliability assessment method considers the impacts of environmental stress and lightning shock on a smart meter. The performance degradation process caused by environmental stress is described by a Wiener model, which is converted into a representation of a PH distribution in a subsequent step. A lightning impulse can cause performance degradation or direct failure of a smart meter. The arrival time of the lightning, the magnitude of the lightning, and the damage caused by the lightning are analyzed separately, and then, the obtained model is expressed in the form of a PH distribution. Finally, a reliability evaluation model of a smart meter based on the PH model under a degradation-shock load is established. The accuracy of the model is verified by comparing the model results with Monte Carlo simulation results.

[1]  Tom Burr,et al.  Introduction to Matrix Analytic Methods in Stochastic Modeling , 2001, Technometrics.

[2]  Qianmei Feng,et al.  Reliability modeling for dependent competing failure processes with changing degradation rate , 2014 .

[3]  Vilijandas Bagdonavičius,et al.  Statistical Analysis of Linear Degradation and Failure Time Data with Multiple Failure Modes , 2004, Lifetime data analysis.

[4]  David W. Coit,et al.  Reliability and maintenance modeling for systems subject to multiple dependent competing failure processes , 2010 .

[5]  David W. Coit,et al.  Reliability Analysis for Multi-Component Systems Subject to Multiple Dependent Competing Failure Processes , 2014, IEEE Transactions on Reliability.

[6]  Tianyuan Ye,et al.  Research on Accelerated Life Test of Smart Meter Based on Degraded Trajectory Model , 2018, ICITEE2018.

[7]  Lei Jiang,et al.  Reliability and Maintenance Modeling for Dependent Competing Failure Processes With Shifting Failure Thresholds , 2012, IEEE Transactions on Reliability.

[8]  Mor Harchol-Balter,et al.  A Closed-Form Solution for Mapping General Distributions to Minimal PH Distributions , 2003, Computer Performance Evaluation / TOOLS.

[9]  Ming Gong,et al.  Reliability assessment of system under a generalized run shock model , 2018, Journal of Applied Probability.

[10]  Junxiang Li,et al.  Time-Dependent Reliability Analysis of Deteriorating Structures Based on Phase-Type Distributions , 2020, IEEE Transactions on Reliability.

[11]  Axel Lehmann Joint modeling of degradation and failure time data , 2009 .

[12]  Peter Buchholz,et al.  A Novel Approach for Phase-Type Fitting with the EM Algorithm , 2006, IEEE Transactions on Dependable and Secure Computing.

[13]  Rui Kang,et al.  Multivariate Degradation Modeling of Smart Electricity Meter with Multiple Performance Characteristics via Vine Copulas , 2017, Qual. Reliab. Eng. Int..

[14]  Enrico Zio,et al.  Smart electricity meter reliability prediction based on accelerated degradation testing and modeling , 2014 .

[15]  Siqi Wang,et al.  A multi-state shock model with mutative failure patterns , 2018, Reliab. Eng. Syst. Saf..

[16]  Haibo Yu,et al.  Failure Mechanism and Effect Analysis of Metering Module of Smart Meter , 2018, 2018 12th International Conference on Reliability, Maintainability, and Safety (ICRMS).

[17]  Mauricio Sánchez-Silva,et al.  Reliability analysis of shock-based deterioration using phase-type distributions , 2014 .

[18]  Somayeh Hamed Ranjkesh,et al.  A new cumulative shock model with damage and inter-arrival time dependency , 2019, Reliab. Eng. Syst. Saf..

[19]  Qianmei Feng,et al.  Modeling zoned shock effects on stochastic degradation in dependent failure processes , 2015 .

[20]  Inmaculada Torres Castro,et al.  A condition-based maintenance of a dependent degradation-threshold-shock model in a system with multiple degradation processes , 2015, Reliab. Eng. Syst. Saf..

[21]  Akira Asakawa,et al.  Estimation of damage rate of electronic watt-hour meters caused by transient magnetic field due to direct lightning strokes to distribution line , 2016, 2016 33rd International Conference on Lightning Protection (ICLP).

[22]  Khac Tuan Huynh,et al.  A periodic inspection and replacement policy for systems subject to competing failure modes due to degradation and traumatic events , 2011, Reliab. Eng. Syst. Saf..

[23]  A. Horváth,et al.  Matching Three Moments with Minimal Acyclic Phase Type Distributions , 2005 .

[24]  Pierre-Etienne Labeau,et al.  Reliability of a multi-state system subject to shocks using phase-type distributions , 2013 .

[25]  Hong-Zhong Huang,et al.  An Approach to Reliability Assessment Under Degradation and Shock Process , 2011, IEEE Transactions on Reliability.

[26]  Steven J. Goodman,et al.  Regional Differences in Tropical Lightning Distributions , 2000 .