Intracoronary stent implantation in native coronary arteries and saphenous vein grafts: a consecutive experience with six types of stents without prolonged anticoagulation.

OBJECTIVE To analyze the results of implantation of six different intracoronary stents without the use of prolonged anticoagulation. MATERIAL AND METHODS Between Mar. 30, 1993, and Jun. 30, 1995, 889 patients with 1,194 coronary or vein graft lesions underwent implantation of one of six types of stents-Palmaz-Schatz, Gianturco-Roubin, Wiktor, Micro, Cordis, or Wallstent. The patients were classified into seven groups on the basis of the type of stent that was implanted, including one group with combined use of two or more types of stents. Among the 851 patients with successful stent delivery and without major complications, 801 received only antiplatelet therapy, and 50 received a standard anticoagulation regimen. One-month clinical followup data were obtained in all patients, and clinical events were investigated. RESULTS The mean number of stents was 1.8 per lesion and 2.4 per patient. Procedural success was achieved in 93% of the lesions. The clinical success rate at 1 month was 90%. Intravascular ultrasound assessment was performed in 90% of the lesions. The final minimal luminal cross-sectional area of the stent increased from 6.8 to 7.8 mm2 after intravascular ultrasound-guided optimization. Within 1 month, 16 stent thrombosis events (1.9%) occurred. No significant differences were noted in stent thrombosis rates among the various stent cohorts. Multivariate logistic regression analysis revealed that the final stent minimal luminal diameter measured by intravascular ultrasonography was the only variable associated with stent thrombosis. CONCLUSION This study showed that six different stents could possibly be inserted without subsequent anticoagulation if optimal stent expansion and total lesion coverage were achieved.

[1]  A. Colombo,et al.  Implantation of the peripheral Wallstent for diffuse lesions in coronary arteries and vein grafts. , 1996, Catheterization and Cardiovascular Diagnosis.

[2]  P. Serruys,et al.  Acute clinical and angiographic results with the new AVE Micro coronary stent in bailout management. , 1995, The American journal of cardiology.

[3]  P Hall,et al.  Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. , 1995, Circulation.

[4]  A. Colombo,et al.  902-6 A Prospective Study of Gianturco-Roubin Coronary Stent Implantation without Anticoagulation , 1995 .

[5]  A. Colombo,et al.  967-19 A Prospective Study of Wiktor Coronary Stent Implantation without Anticoagulation , 1995 .

[6]  A. Colombo,et al.  967–16 Preliminary Experience of Coronary Stenting with the Micro Stent™ , 1995 .

[7]  E. Topol,et al.  Comparison of three coronary stents: clinical and angiographic outcome after elective placement in 134 consecutive patients. , 1994, Catheterization and cardiovascular diagnosis.

[8]  S. Goldberg,et al.  Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents. , 1994, Journal of the American College of Cardiology.

[9]  P. Teirstein,et al.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. , 1994, The New England journal of medicine.

[10]  W Rutsch,et al.  A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. , 1994, The New England journal of medicine.

[11]  S. Goldberg,et al.  Intracoronary ultrasound observations during stent implantation. , 1994, Circulation.

[12]  P. Serruys,et al.  Intracoronary stents: a review of the experience with five different devices in clinical use. , 1994, Journal of interventional cardiology.

[13]  J. Tobis,et al.  Preliminary experience with intravascular ultrasound guided Palmaz-Schatz coronary stenting: the acute and short-term results on a consecutive series of patients. , 1994, Journal of interventional cardiology.

[14]  M. Nobuyoshi,et al.  Serial angiographic follow-up after Palmaz-Schatz stent implantation: comparison with conventional balloon angioplasty. , 1993, Journal of the American College of Cardiology.

[15]  E. Topol,et al.  Thrombosis of a flexible coil coronary stent: frequency, predictors and clinical outcome. , 1993, Journal of the American College of Cardiology.

[16]  U. Sigwart,et al.  Angiographic restenosis after successful Wallstent stent implantation: an analysis of risk predictors. , 1992, American heart journal.

[17]  A. Colombo,et al.  Initial experience with the disarticulated (one-half) Palmaz-Schatz stent: a technical report. , 1992, Catheterization and Cardiovascular Diagnosis.

[18]  Julio C. Palmaz,et al.  Clinical Experience With the Palmaz‐Schatz Coronary Stent: Initial Results of a Multicenter Study , 1991, Circulation.

[19]  C. Lambert,et al.  Videodensitometry versus digital calipers for quantitative coronary angiography. , 1990, The American journal of cardiology.

[20]  T. Ryan Guidelines for percutaneous transluminal coronary angioplasty. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty). , 1988, Journal of the American College of Cardiology.

[21]  E L Bolson,et al.  A new digital electronic caliper for measurement of coronary arterial stenosis: comparison with visual estimates and computer-assisted measurements. , 1984, The American journal of cardiology.