Performance comparison of liquid desiccant air handling processes from the perspective of match properties

The energy consumption of air-conditioning systems represents a large part of the entire building energy consumption in non-residential buildings. Heat pump-driven liquid desiccant (HPLD) systems have become more and more popular because of their high energy efficiency, and there are many different ways to utilize the condensing heat in this type of air handling device. In the present study, the match properties of the heat and mass transfer processes in the air–desiccant system varying with the inlet air states are investigated, and the unmatched coefficient based on entransy dissipation is adopted to evaluate the performance of HPLD systems. It is demonstrated that the unmatched coefficient of the process along the iso-concentration line is much lower than that along the isenthalpic line. A higher unmatched coefficient means a higher heat or mass transfer resistance caused by the unmatched flow rates or parameters. The HPLD system in which solution is heated for regeneration (Basic Type II) performs much better than the system in which regeneration air is heated (Basic Type I). The unmatched coefficients of the condenser and regenerator decrease from 2.70 and 1.34, respectively, in Basic Type I, to 1.07 and 1.05, respectively, in Basic Type II. Moreover, COPsys is significantly improved, rising from 1.83 to 4.17.

[1]  Xingang Liang,et al.  Computation of effectiveness of two-stream heat exchanger networks based on concepts of entropy generation, entransy dissipation and entransy-dissipation-based thermal resistance , 2012 .

[2]  Omar M. Al-Rabghi,et al.  Proposed energy-efficient air-conditioning system using liquid desiccant , 1996 .

[3]  XinGang Liang,et al.  Entransy—A physical quantity describing heat transfer ability , 2007 .

[4]  Ruzhu Wang,et al.  Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning , 2001 .

[5]  Yi Jiang,et al.  Similarity of coupled heat and mass transfer between air–water and air–liquid desiccant direct-contact systems , 2009 .

[6]  Donggen Peng,et al.  Feasibility and performance analysis of a desiccant solution regenerator using hot air , 2011 .

[7]  Li Zhang,et al.  Combination of air-source heat pumps with liquid desiccant dehumidification of air , 2012 .

[8]  Xiaoqiang Zhai,et al.  Performance analysis on a hybrid air-conditioning system of a green building , 2006 .

[9]  Ye Yao,et al.  Investigation on the kinetic models for the regeneration of silica gel by hot air combined with power ultrasonic , 2011 .

[10]  Kiyoshi Saito,et al.  Hybrid liquid desiccant air-conditioning system: Experiments and simulations , 2011 .

[11]  Ahmed M. Hamed,et al.  The effect of inlet parameters on the performance of packed tower-regenerator , 2002 .

[12]  Alsaied Khalil AN EXPERIMENTAL STUDY ON MULTI-PURPOSE DESICCANT INTEGRATED VAPOR-COMPRESSION AIR-CONDITIONING SYSTEM , 2012 .

[13]  S. Jain,et al.  Experimental performance of a liquid desiccant dehumidification system under tropical climates , 2011 .

[14]  Yi Jiang,et al.  Match properties of heat transfer and coupled heat and mass transfer processes in air-conditioning system , 2012 .

[15]  Tao Zhang,et al.  Performance optimization of heat pump driven liquid desiccant dehumidification systems , 2012 .

[16]  K. Y. Qu,et al.  Heat and mass transfer model of cross flow liquid desiccant air dehumidifier/regenerator , 2007 .

[17]  Ruzhu Wang,et al.  Development of a novel two-stage liquid desiccant dehumidification system assisted by CaCl2 solution using exergy analysis method , 2010 .

[18]  Ye Yao,et al.  Feasibility study on power ultrasound for regeneration of silica gel--A potential desiccant used in air-conditioning system , 2009 .

[19]  Y. K. Yadav Vapour-compression and liquid-desiccant hybrid solar space-conditioning system for energy conservation , 1995 .

[20]  Abdulghani A. Al-Farayedhi,et al.  Regeneration of liquid desiccants using membrane technology , 1999 .