Control Method for Fault-Tolerant Active Power Filters

New direct and indirect current control methods for a fault-tolerant active power filter topology are presented in this paper. Since a three-phase four-switch topology has a phase bridge current which cannot be directly controlled, a hysteresis control method in the α-β plane which controls the three-phase current in the two-phase stationary coordinate system is proposed. The improved SVPWM algorithm is able to eliminate the operation of the trigonometric functions in the traditional algorithm by rotating the α-β coordinates and alternating the sequence of the output vectors, which in turn simplifies the algorithm and reduces the switching frequency. The selection of the DC-side reference voltage and DC-side capacitor equalization strategy are also discussed. Simulation and experiments demonstrate that the proposed control method is correct and feasible.

[1]  John Shen,et al.  Double Closed-Loop Control Method for Injection-Type Hybrid Active Power Filter , 2011, IEEE Transactions on Power Electronics.

[2]  Fan Fuhua A Novel Algorithm of SVPWM Applied to Active Power Filters , 2012 .

[3]  P. Garcia-Gonzalez,et al.  Application of a Repetitive Controller for a Three-Phase Active Power Filter , 2007, IEEE Transactions on Power Electronics.

[4]  M.N. Uddin,et al.  Fuzzy-logic-controller-based cost-effective four-switch three-phase inverter-fed IPM synchronous motor drive system , 2006, IEEE Transactions on Industry Applications.

[5]  Quoc-Nam Trinh,et al.  An Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters , 2013, IEEE Transactions on Industrial Electronics.

[6]  Marco Rivera,et al.  Improved Active Power Filter Performance for Renewable Power Generation Systems , 2014, IEEE Transactions on Power Electronics.

[7]  Jia-Hong Liu,et al.  Modeling and Control of a Three-Phase Four-Switch PWM Voltage-Source Rectifier in d-q Synchronous Frame , 2011, IEEE Transactions on Power Electronics.

[8]  Zhou Li,et al.  Space vector pulse-width modulation algorithm and DC-side voltage control strategy of three-phase four-switch active power filters , 2013 .

[9]  Ahmed Faheem Zobaa,et al.  Optimal multiobjective design of hybrid active power filters considering a distorted environment , 2014, IEEE Transactions on Industrial Electronics.

[10]  Peng Jian-chun Study on Current Command Signal of Three-phase Four-switch Shunt Active Power Filter , 2009 .

[11]  Changliang Xia,et al.  A Control Strategy for Four-Switch Three-Phase Brushless DC Motor Using Single Current Sensor , 2009, IEEE Transactions on Industrial Electronics.

[12]  El Madjid Berkouk,et al.  A Novel Space-Vector Current Control Based on Circular Hysteresis Areas of a Three-Phase Neutral-Point-Clamped Inverter , 2010, IEEE Transactions on Industrial Electronics.

[13]  Frede Blaabjerg,et al.  Active Harmonic Filtering Using Current-Controlled, Grid-Connected DG Units With Closed-Loop Power Control , 2014, IEEE Transactions on Power Electronics.

[14]  Hui Wang,et al.  Variable parameter pulse width modulation-based current tracking technology applied to four-switch three-phase shunt active power filter , 2013 .

[15]  M. Nakaoka,et al.  Advanced current control implementation with robust deadbeat algorithm for shunt single-phase voltage-source type active power filter , 2004 .

[16]  Danwei Wang,et al.  Unified robust zero-error tracking control of CVCF PWM converters , 2002 .