Moisture buffering capacity of highly absorbing materials

Abstract This research investigates the possibility to use highly absorbing materials to dampen indoor RH% variations. The practical MBV of sodium polyacrylate, cellulose-based material, perlite and gypsum is evaluated for a daily cyclic exposure that alternates high (75%) and low (33%) RH% levels for 8 h and 16 h, respectively. The adjustment velocity to RH% variations and the presence of hysteretic phenomena are also presented. The cellulose-based material proves to be the most suitable for moisture buffering applications. Starting from this material’s properties, the effect of thickness, vapour resistance factor (μ) and mass surface exchange coefficient (Zv) on sorption capacity is evaluated by the use of a numerical model.

[1]  Kaisa Svennberg,et al.  Moisture Buffering in the Indoor Environment , 2006 .

[2]  Tim Padfield The role of absorbent building materials in moderating changes of relative humidity: Ph.D.thesis , 1999 .

[3]  Carey J. Simonson,et al.  Moisture buffering capacity of hygroscopic building materials: Experimental facilities and energy impact , 2006 .

[4]  A. Gustavsen,et al.  Moisture Buffering of Building Materials , 2005 .

[5]  Prabal Talukdar,et al.  Effect of initial conditions, boundary conditions and thickness on the moisture buffering capacity of spruce plywood , 2006 .

[6]  C. Simonson,et al.  Improving indoor climate and comfort with wooden structures , 2001 .

[7]  Miimu Matilainen,et al.  Moisture conditions and energy consumption in heated crawl spaces in cold climates , 2003 .

[8]  C. Simonson,et al.  The effect of structures on indoor humidity--possibility to improve comfort and perceived air quality. , 2002, Indoor air.

[9]  Stéphane Hameury,et al.  Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study , 2005 .

[10]  Stéphane Hameury,et al.  Contribution of indoor exposed massive wood to a good indoor climate: in situ measurement campaign , 2004 .

[11]  Klaus Sedlbauer,et al.  Prediction of Mould Growth by Hygrothermal Calculation , 2002 .

[12]  François Garde,et al.  Study of moisture in buildings for hot humid climates , 2002 .

[13]  P. Fanger,et al.  Impact of Temperature and Humidity on the Perception of Indoor Air Quality , 1998 .

[14]  P. Fanger,et al.  Upper limits for indoor air humidity to avoid uncomfortably humid skin , 1998 .

[15]  P. Fanger,et al.  Upper limits of air humidity for preventing warm respiratory discomfort , 1998 .