Diethyldithiocarbamate-sensitive electrode for the simultaneous determination of metals

An electrode sensitive for diethyldithiocarbamate ions (DDC) down to 10/sup -5/ M is prepared by precipitation of copper diethyldithiocarbamate and silver sulfide within a graphite rod. The electrode is used as a monitor for simultaneous titration of binary, tertiary, and quaternary metallic mixtures of Cu, Cd, Ni, Pb, V, Th, and Zn in 50 to 75% ethanol at pH 4 to 6 using NaDDC as a titrant. Stepwise titration curves with sharp end point breaks and results with an average recovery of 98.5% (mean standard deviation +- 0.4%) are obtained with as little as 50 ..mu..g/mL of all these metal ions. Application of the method to simultaneous determination of some major elements in five different copper-base alloys gives results which compare favorably with certified values.

[1]  B. Morelli Determination of nickel(II) and copper(II) and lead(II) and copper(II) in mixtures by complexometric titration , 1980 .

[2]  B. Demetriou,et al.  Assay of procyclidine hydrochloride, cyclizine hydrochloride and diethylcarbamazine citrate in tablets using ion-responsive electrodes. , 1980, The Analyst.

[3]  D. Jagner Potentiometric stripping analysis in non-deaerated samples , 1979 .

[4]  A. Bond,et al.  Use of computerized instrumentation for pseudo-derivative direct current and normal pulse polarography with correction for charging current , 1978 .

[5]  J. Turner,et al.  Rapid Scan Alternate Drop Pulse Polarographic Methods. , 1978 .

[6]  M. Oehme,et al.  The determination of copper, lead, cadmium and zinc in human teeth by anodic stripping voltammetry , 1978 .

[7]  C. Fragale,et al.  Simultaneous determination of copper, lead and zinc in wine by differential pulse polarography. , 1978, The Analyst.

[8]  G. Baiulescu,et al.  Construction of a new Hg(2+)-selective liquid-state electrode. , 1977, Talanta.

[9]  W. P. Bennekom High-performance pulse and differential pulse polarography: Part I. Theoretical considerations , 1977 .

[10]  A. Hubbard,et al.  Differential double pulse voltammetry at chemically modified platinum electrodes for in vivo determination of catecholamines. , 1976, Analytical chemistry.

[11]  C. M. Elliott,et al.  Chemically modified carbon electrodes , 1976 .

[12]  A. Bond,et al.  Pseudo-derivative d.c. and pulse polarographic methods at short drop times , 1976 .

[13]  J. H. Christie,et al.  Alternate drop pulse polarography , 1976 .

[14]  G. Boef,et al.  Solid-state ion-selective electrodes as end-point detectors in ompleximetric titrations: Part I. The titration of mixtures of two metals , 1975 .

[15]  N. Klein,et al.  Improved differential pulse polarography , 1975 .

[16]  J. H. Christie,et al.  Direct current effects in pulse polarography at the dropping mercury electrode , 1974 .

[17]  G. Guidotti,et al.  Simultaneous coulometric determination of silver, cadmium, and indium in ternary alloys , 1971 .

[18]  L. Kalbus,et al.  The potentiometric titration of silver and copper with dithiooxamide , 1971 .

[19]  J. Ruzicka,et al.  A new type of solid-state ion-selective electrodes with insoluble sulphides or halides , 1971 .

[20]  M. S. Frant,et al.  Chelometric indicator titrations with the solid-state cupric ion-selective electrode , 1969 .

[21]  J. Starý,et al.  Determination of extraction constants of metal diethyldithiocarbamates , 1968 .

[22]  A. Hulanicki Complexation reactions of dithiocarbamates. , 1967, Talanta.

[23]  R. A. Osteryoung,et al.  Evaluation of Analytical Pulse Polarography , 1965 .

[24]  S. P. Perone,et al.  The Application of Stripping Analysis to the Determination of Silver(I) Using Graphite Electrodes. , 1963 .

[25]  C. Auerbach,et al.  Incremental Approach to Derivative Polarography , 1961 .