Overestimation of low cardiac output measured by thermodilution.
暂无分享,去创建一个
[1] H. Brandenberger. 3.3 Hypnotics and Sedatives Not Belonging to the Classes of Barbiturates and Benzodiazepines , 1997 .
[2] G. Kissling,et al. Validity of thermal dilution technique for measurement of cardiac output in rats. , 1993, The American journal of physiology.
[3] M. Morton,et al. Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility , 1993, Critical care medicine.
[4] S. Dohi,et al. Haemodynamic changes associated with thermodilution cardiac output determination during myocardial ischaemia or pulmonary oedema in dogs , 1992, Acta anaesthesiologica Scandinavica.
[5] J. Machecourt,et al. Mesure du débit cardiaque par méthodes invasives: méthodes et variabilité , 1992 .
[6] P. Jebson,et al. Continuous Fick cardiac output compared to continuous pulmonary artery electromagnetic flow measurement in pigs. , 1987, Anesthesiology.
[7] R. Byrick,et al. Effects of tricuspid regurgitation on thermodilution cardiac output: Studies in an animal model , 1987, Canadian journal of anaesthesia = Journal canadien d'anesthesie.
[8] M. C. Rogers,et al. The slowing of sinus rhythm during thermodilution cardiac output determination and the effect of altering injectate temperature. , 1985, Anesthesiology.
[9] G. Bisgard,et al. Limitations of thermodilution cardiac output measurements in the rat. , 1984, The American journal of physiology.
[10] B. Groves,et al. Thermodilution method overestimates low cardiac output in humans. , 1983, The American journal of physiology.
[11] D. Mcwilliam,et al. A comparison of methods of cardiac output measurement. , 1983, Anaesthesia and intensive care.
[12] S. Dohi,et al. Slowing of heart rate during cardiac output measurement by thermodilution. , 1982, Anesthesiology.
[13] M. C. Rogers,et al. Overestimation of Pediatric Cardiac Output by Thermal Indicator Loss , 1982, Circulation.
[14] R. Weisel,et al. Measurement of Cardiac Output by Thermodilution , 1975 .
[15] H. Swan,et al. Measurement of blood flow by thermodilution. , 1972, The American journal of cardiology.
[16] James S. Forrester,et al. A new technique for measurement of cardiac output by thermodilution in man , 1971 .
[17] G. Fegler,et al. MEASUREMENT OF CARDIAC OUTPUT IN ANÆSTHETIZED ANIMALS BY A THERMO‐DILUTION METHOD , 1954 .
[18] E. Winslow,et al. Effects of iced and room temperature injectate on cardiac output measurements in critically ill patients with low and high cardiac outputs. , 1993, Heart & lung : the journal of critical care.
[19] B. Lavandier,et al. Aortic blood flow measurement , 1988 .
[20] E. Varnauskas,et al. Validity and reproducibility of determination of cardiac output by thermodilution in man. , 1970, Cardiology.
[21] G. Fegler,et al. Measurement of cardiac output in anaesthetized animals by a thermodilution method. , 1954, Quarterly journal of experimental physiology and cognate medical sciences.