Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.

OBJECTIVES Comparison of the effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture. DESIGN Randomized, prospective. SETTING Orthopaedic research laboratory. ANIMALS Ten large (greater than twenty-five kilogram) adult dogs. INTERVENTION A short, midshaft spiral tibial fracture was created, followed by lag screw fixation and neutralization with an eight-hole, 3.5-millimeter, low-contact dynamic compression plate (LCDCP) made of either 316L stainless steel (n = five) or commercially pure titanium (n = five). After surgery, animals were kept with unrestricted weight-bearing in individual stalls for ten weeks. MAIN OUTCOME MEASUREMENTS Cortical bone blood flow was assessed by laser Doppler flowmetry using a standard metalshafted probe (Periflux Pf303, Perimed, Jarfalla, Sweden) applied through holes in the custom-made LCDCPs at five sites. Bone blood flow was determined at four times: (a) prefracture, (b) postfracture, (c) postplating, and (d) ten weeks postplating. After the dogs were killed, the implant was removed and both the treated tibia and contralateral tibia were tested for bending stiffness and load to failure. RESULTS Fracture creation decreased cortical perfusion in both groups at the fracture site (p = 0.02). The application of neither stainless steel nor titanium LCDCPs further decreased cortical bone blood flow after fracture creation. However, at ten weeks postplating, cortical perfusion significantly increased compared with acute postplating levels in the stainless steel (p = 0.003) and titanium (p = 0.001) groups. Cortical bone blood flow ten weeks postplating was not significantly different between the titanium group and the stainless steel group. Biomechanical tests performed on the tibiae with the plates removed did not reveal any differences in bending stiffness nor load required to cause failure between the two groups. CONCLUSIONS Both titanium and stainless steel LCDCPs were equally effective in allowing revascularization, and neither provided a significant advantage in biomechanical properties of fracture healing at ten weeks.

[1]  S. Perren The biomechanics and biology of internal fixation using plates and nails. , 1989, Orthopedics.

[2]  S. Perren The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP). Scientific background, design and application. , 1991, Injury.

[3]  P. Kelly,et al.  The effect of fixation with intramedullary rods and plates on fracture-site blood flow and bone remodeling in dogs. , 1977, The Journal of bone and joint surgery. American volume.

[4]  W. Harris,et al.  Effects on intact femora of dogs of the application and removal of metal plates. A metabolic and structural study comparing stiffer and more flexible plates. , 1978, The Journal of bone and joint surgery. American volume.

[5]  M. Swiontkowski,et al.  Laser doppler flowmetry for bone blood flow measurements: Helium–neon laser light attenuation and depth of perfusion assessment , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  P. Kelly,et al.  Effect of fracture fixation on cortical bone blood flow , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  O. Reikerås,et al.  Blood flow and mechanical properties of healing bone. Femoral osteotomies studied in rats. , 1992, Acta orthopaedica Scandinavica.

[8]  P. Kelly,et al.  Blood flow and mineral deposition in canine tibial fractures. , 1975, The Journal of bone and joint surgery. American volume.

[9]  S. Woo,et al.  A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffness. , 1976, The Journal of bone and joint surgery. American volume.

[10]  S. Johnston,et al.  A biomechanical comparison of 7-hole 3.5 mm broad and 5-hole 4.5 mm narrow dynamic compression plates. , 1991, Veterinary surgery : VS.

[11]  R. Jacobs,et al.  Effects of plates on cortical bone perfusion. , 1981, The Journal of trauma.

[12]  J. Jupiter,et al.  Low-contact dynamic compression plating of the clavicle. , 1994, Injury.

[13]  F. W. Rhinelander,et al.  Tibial blood supply in relation to fracture healing. , 1974, Clinical orthopaedics and related research.

[14]  M M Panjabi,et al.  The four biomechanical stages of fracture repair. , 1977, The Journal of bone and joint surgery. American volume.