Coupling effect of ventilation duct bend with different shapes and sizes

The coupling effect of local components is common in buildings and results in energy loss and local drag. This effect is significantly influenced by the shape and size of the components. However, only a few studies have focused on this topic. The numerical simulation method of Reynolds stress model (RSM) is adopted in the present study to investigate the typically coupled local components of ventilation and air conditioning ducts, namely, the coupled bend. By focusing on the core speed and segmented drag in the coupled bend, this study explores the effects of aspect ratio and curvature radius on drag and core speed. This study provides a theoretical basis for the design, construction, and operation management of local components of ventilation and air conditioning ducts. Two evident core-speed reduction processes are observed in the coupled bend and its downstream. With increasing curvature radius (R/D), the drop in core speed downstream decreases gradually in the S-shaped and U-shaped bends.

[1]  Donald S. Miller Internal flow system , 1990 .

[2]  S. T. Taylor,et al.  HVAC systems and equipment , 1990 .

[3]  Kyros Yakinthos,et al.  Modeling the flow in a 90° rectangular duct using one Reynolds-stress and two eddy-viscosity models , 2008 .

[4]  Lennart Löfdahl,et al.  Numerical validations of secondary flows and loss development downstream of a highly loaded low pressure turbine outlet guide vane cascade , 2007 .

[5]  Marta Maria Sesana,et al.  Assessing energy and thermal comfort of different low-energy cooling concepts for non-residential buildings , 2013 .

[6]  C. M. Mak,et al.  Pressure Losses across Multiple Fittings in Ventilation Ducts , 2013, TheScientificWorldJournal.

[7]  Jie Cui,et al.  Laminar Pressure Loss Coefficient in Close Coupled Fittings , 2006 .

[8]  B. Allan,et al.  Experimental and Computational Evaluation of Flush-Mounted, S-Duct Inlets , 2004 .

[9]  Karen A. Thole,et al.  Experimental validation of large eddy simulations of flow and heat transfer in a stationary ribbed duct , 2006 .

[10]  Lei Chen,et al.  Study on local drag reduction effects of wedge-shaped components in elbow and T-junction close-coupled pipes , 2014 .

[11]  Hani H. Sait,et al.  Auditing and analysis of energy consumption of an educational building in hot and humid area , 2013 .

[12]  Xiangfei Kong,et al.  Investigation and analysis on the energy consumption of starred hotel buildings in Hainan Province, the tropical region of China , 2013 .

[13]  Angui Li,et al.  Modeling deposition of particles in vertical square ventilation duct flows , 2011 .

[14]  Edward K. Levy,et al.  Gas–solid flow behavior in a horizontal pipe after a 90° vertical-to-horizontal elbow , 2001 .

[15]  S. Bernardo,et al.  3-D computational fluid dynamics for gas and gas-particle flows in a cyclone with different inlet section angles , 2006 .

[16]  Ahmad K. Sleiti,et al.  Comparison between EVM and RSM turbulence models in predicting flow and heat transfer in rib-roughened channels , 2006 .

[17]  Peter Spicka,et al.  Gas–liquid flow in a 2D column: Comparison between experimental data and CFD modelling , 2001 .

[18]  Woongsup Yoon,et al.  Fluid dynamics in starting and terminating transients of zero-secondary flow ejector , 2008 .