Engineering Techniques Applied to the Analysis and Control of In-Series Cardiac Assistance

This paper traces the development of in-series cardiac assist devices and describes the contributions of engineering methodology to the analyis of the interaction between the device and the cardiovascular system. Special emphasis is placed on issues regarding the control and optimization of this method of assistance. Recent results of our theoretical and experimental investigations are summarized. These results demonstrate that automatic control of in-series cardiac assist devices is essential to their effectiveness and is critical for preventing untoward hemodynamic effects. Guidelines concerning the design of algorithms for optimization of cardiac assistance are discussed.

[1]  H. Kambic,et al.  Sequential external counterpulsation (SECP) in China. , 1983, Transactions - American Society for Artificial Internal Organs.

[2]  K. Sagawa The ventricular pressure-volume diagram revisited. , 1978, Circulation research.

[3]  M. Thubrikar,et al.  The Elastic Modulus of Canine Aortic Valve Leaflets in Vivo and in Vitro , 1980, Circulation research.

[4]  D. A. Mcdonald,et al.  Regional pulse-wave velocity in the arterial tree. , 1968, Journal of applied physiology.

[5]  W J KOLFF,et al.  Diastolic balloon pumping (with carbon dioxide) in the aorta--a mechanical assistance to the failing circulation. , 1962, American heart journal.

[6]  R. Clauss,et al.  Assisted circulation. I. The arterial counterpulsator. , 1961, The Journal of thoracic and cardiovascular surgery.

[7]  S. Chatterjee,et al.  Evaluation of intra-aortic balloon counterpulsation. , 1971, The Journal of thoracic and cardiovascular surgery.

[8]  R J Hillestad,et al.  Computer modeling of the human systemic arterial tree. , 1968, Journal of biomechanics.

[9]  V. Rideout,et al.  Difference-differential equations for fluid flow in distensible tubes. , 1967, IEEE transactions on bio-medical engineering.

[10]  M J Williams,et al.  Experimental determination of optimum performance of counterpulsation assist pumping under computer control. , 1977, Computers and biomedical research, an international journal.

[11]  W Welkowitz,et al.  Control system for circulatory assist devices: determination of suitable control variables. , 1982, Transactions - American Society for Artificial Internal Organs.

[12]  J W Clark,et al.  On the feasibility of closed-loop control of intra-aortic balloon pumping. , 1973, IEEE transactions on bio-medical engineering.

[13]  E. Attinger,et al.  Pressure‐Flow Relations in Dog Arteries , 1966, Circulation research.

[14]  A. Kantrowitz Experimental augmentation of coronary flow by retardation of the arterial pressure pulse. , 1953, Surgery.

[15]  A Kantrowitz,et al.  Initial clinical experience with intraaortic balloon pumping in cardiogenic shock. , 1968, JAMA.

[16]  R H Cox,et al.  Pressure-flow relations in the vessels of the canine aortic arch. , 1975, The American journal of physiology.

[17]  Hiroyukisuga,et al.  Instantaneous Pressure-Volume Relationships and Their Ratio in the Excised, Supported Canine Left Ventricle , 1974 .

[18]  R. Clauss,et al.  Assisted circulation. , 1961, The Ohio State medical journal.

[19]  J. Ross,et al.  Intraaortic balloon pumping in the experimental animal. Effects and problems. , 1971, The American journal of cardiology.

[20]  Dov Jaron,et al.  Theoretical Considerations Regarding the Optimization of Cardiac Assistance by lntraaortic Balloon Pumping , 1983, IEEE Transactions on Biomedical Engineering.

[21]  M F O'Rourke,et al.  Pressure and flow waves in systemic arteries and the anatomical design of the arterial system. , 1967, Journal of applied physiology.

[22]  William J. Ohley,et al.  Validity of an Arterial System Model: A Quantitative Evaluation , 1980, IEEE Transactions on Biomedical Engineering.

[23]  D Jaron,et al.  Analysis of assisted circulation. , 1972, Bibliotheca cardiologica.

[24]  F. Roberge,et al.  Computation of aortic pulse wave velocity and aortic pulse wave velocity and aortic extensibility from pressure gradient measurements. , 1975, Canadian journal of physiology and pharmacology.

[25]  W. Webb,et al.  Influence of counterpulsation on aortic right and left coronary blood flow following ligation of the left circumflex coronary artery. , 1970, The Journal of thoracic and cardiovascular surgery.

[26]  C. Sanders,et al.  Mechanical Circulatory Assistance: Current Status and Experience with Combining Circulatory Assistance, Emergency Coronary Angiography, and Acute Myocardial Revascularization , 1972, Circulation.

[27]  J. S. Janicki,et al.  Intraaortic Balloon Counterpulsation: A Review of Physiological Principles, Clinical Results, and Device Safety , 1974 .

[28]  S R Igo,et al.  Intra-aortic balloon pumping: theory and practice. Experience with 325 patients. , 1978, Artificial organs.

[29]  R. Clauss,et al.  The evolution of counterpulsation techniques. , 1976, Medical instrumentation.

[30]  T. Akutsu,et al.  A clinical experience with an implanted mechanical auxiliary ventricle. , 1966, JAMA.

[31]  R. T. Jones,et al.  Theoretical and experimental analysis of the intra-aortic balloon pump. , 1968, Transactions - American Society for Artificial Internal Organs.