Binder-jetting 3D printing and alloy development of new biodegradable Fe-Mn-Ca/Mg alloys.

3D printing of various biomaterials including titanium and stainless steel has been studied for treating patients with cranio-maxillofacial bone defect. The potential long term complications with use of inert biometals have opened the opportunities for use of biodegradable metals in the clinical arena. The authors previously reported that binder-jet 3D printing technique enhanced the degradation rates of biodegradable Fe-Mn alloy by creating engineered micropores rendering the system attractive as biodegradable implantable devices. In the present study, the authors employed CALPHAD modeling to systematically study and modify the Fe-Mn alloy composition to achieve enhanced degradation rates. Accordingly, Ca and Mg addition to Fe-35wt% Mn solid solution predicted increase in degradation rates. In order to validate the CALPHAD results, Fe - (35-y)wt% Mn - ywt% X (X=Ca, Mg, and y=0, 1, 2) were synthesized by using high energy mechanical alloying (HEMA). Sintered pellets of Fe-Mn-Ca and Fe-Mn-Mg were then subjected to potentiodynamic polarization (PDP) and live/dead cell viability tests. Sintered pellets of Fe-Mn, Fe-Mn-Ca, and Fe-Mn-Mg also exhibited MC3T3 murine pre-osteoblast cells viability in the live/dead assay results. Fe-Mn and Fe-Mn-1Ca were thus accordingly selected for 3D printing and the results further confirmed enhanced degradation of Ca addition to 3D printed constructs validating the theoretical and alloy development studies. Live/dead and MTT cell viability results also confirmed good cytocompatibility of the 3D-printed Fe-Mn and Fe-Mn-1Ca constructs. STATEMENT OF SIGNIFICANCE Bone grafting is widely used for the treatment of cranio-maxillofacial bone injuries. 3D printing of biodegradable Fe alloy is anticipated to be advantageous over current bone grafting techniques. 3D printing offers the fabrication of precise and tailored bone grafts to fit the patient specific bone defect needs. Biodegradable Fe alloy is a good candidate for 3D printing synthetic grafts to regenerate bone tissue without eliciting complications. CALPHAD theoretical models were used to develop new Fe-Mn-Ca/Mg alloys to enhance the degradation rates of traditional Fe-Mn alloys. In vitro experimental results also showed enhanced degradation rates and good cytocompatibility of sintered Fe-Mn-Ca/Mg compacts. 3D printing of Fe-Mn and Fe-Mn-1Ca alloys further demonstrated their feasibility as potentially viable bone grafts for the future.

[1]  Diego Mantovani,et al.  Iron–manganese: New class of metallic degradable biomaterials prepared by powder metallurgy , 2008 .

[2]  D. Dimitrov,et al.  Advances in three dimensional printing – state of the art and future perspectives , 2006 .

[3]  M. Bohner,et al.  Resorbable biomaterials as bone graft substitutes , 2010 .

[4]  Henning Windhagen,et al.  Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study , 2013, BioMedical Engineering OnLine.

[5]  D. Kaplan,et al.  Porosity of 3D biomaterial scaffolds and osteogenesis. , 2005, Biomaterials.

[6]  Gunasekaran Kumar,et al.  Morbidity at Bone Graft Donor Sites , 2014 .

[7]  P. Uggowitzer,et al.  Biodegradable Fe-based alloys for use in osteosynthesis: outcome of an in vivo study after 52 weeks. , 2014, Acta biomaterialia.

[8]  Mark Taylor,et al.  Free form fabricated features on CoCr implants with and without hydroxyapatite coating in vivo: a comparative study of bone contact and bone growth induction , 2011, Journal of materials science. Materials in medicine.

[9]  P. Uggowitzer,et al.  Degradation performance of biodegradable Fe-Mn-C(-Pd) alloys. , 2013, Materials science & engineering. C, Materials for biological applications.

[10]  A. Harders,et al.  Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. , 1995, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[11]  F. Witte,et al.  Biodegradable Metals , 2018, Biomaterials Science.

[12]  L. Höglund,et al.  Thermo-Calc & DICTRA, computational tools for materials science , 2002 .

[13]  Wojciech Dec,et al.  Best Face Forward: Virtual Modeling and Custom Device Fabrication to Optimize Craniofacial Vascularized Composite Allotransplantation , 2013, Plastic and reconstructive surgery.

[14]  F. Beckmann,et al.  The morphology of anisotropic 3D-printed hydroxyapatite scaffolds. , 2008, Biomaterials.

[15]  M. Peuster,et al.  In vitro and in vivo corrosion properties of new iron-manganese alloys designed for cardiovascular applications. , 2015, Journal of biomedical materials research. Part B, Applied biomaterials.

[16]  T. Langdon,et al.  Improving the mechanical properties of magnesium and a magnesium alloy through severe plastic deformation , 2001 .

[17]  P. Cao,et al.  A comparative study of powder metallurgical (PM) and wrought Fe–Mn–Si alloys , 2015 .

[18]  P. Manson,et al.  Detection of Titanium in Human Tissues after Craniofacial Surgery , 1977, Plastic and reconstructive surgery.

[19]  S. Hollister Porous scaffold design for tissue engineering , 2005, Nature materials.

[20]  J O Hollinger,et al.  The critical size defect as an experimental model to test bone repair materials. , 1990, The Journal of craniofacial surgery.

[21]  Yufeng Zheng,et al.  In vitro investigation of Fe30Mn6Si shape memory alloy as potential biodegradable metallic material , 2011 .

[22]  Volker Wesling,et al.  Selective Laser Melting of Magnesium and Magnesium Alloys , 2013 .

[23]  J. Frame,et al.  Detection of titanium in human tissues after craniofacial surgery. , 1998, Plastic and reconstructive surgery.

[24]  J. Čadek,et al.  Dislocation structure in the high temperature creep of metals and solid solution alloys: a review , 1986 .

[25]  Guang-Ling Song,et al.  Control of biodegradation of biocompatable magnesium alloys , 2007 .

[26]  N. Saunders,et al.  CALPHAD : calculation of phase diagrams : a comprehensive guide , 1998 .

[27]  Yufeng Zheng,et al.  In vitro study on newly designed biodegradable Fe-X composites (X = W, CNT) prepared by spark plasma sintering. , 2013, Journal of biomedical materials research. Part B, Applied biomaterials.

[28]  J O Hollinger,et al.  The critical size defect as an experimental model for craniomandibulofacial nonunions. , 1986, Clinical orthopaedics and related research.

[29]  D. Mantovani,et al.  Caveolin: a possible biomarker of degradable metallic materials toxicity in vascular cells. , 2013, Acta biomaterialia.

[30]  P. Kumta,et al.  First-principles studies on alloying and simplified thermodynamic aqueous chemical stability of calcium-, zinc-, aluminum-, yttrium- and iron-doped magnesium alloys. , 2010, Acta biomaterialia.

[31]  Yufeng Zheng,et al.  In vitro degradation and biocompatibility of Fe-Pd and Fe-Pt composites fabricated by spark plasma sintering. , 2014, Materials science & engineering. C, Materials for biological applications.

[32]  S. Allen,et al.  Corrosion behavior of advanced titanium-based alloys made by three-dimensional printing (3DPTM) for biomedical applications , 2001 .

[33]  A. Gebhardt,et al.  Custom-made cast titanium implants produced with CAD/CAM for the reconstruction of cranium defects. , 1998, International journal of oral and maxillofacial surgery.

[34]  Young‐kook Lee,et al.  Damping Capacity in Fe-Mn Binary Alloys , 1997 .

[35]  Yufeng Zheng,et al.  The development of binary Mg-Ca alloys for use as biodegradable materials within bone. , 2008, Biomaterials.

[36]  P. Uggowitzer,et al.  Design strategy for biodegradable Fe-based alloys for medical applications. , 2010, Acta biomaterialia.

[37]  Yufeng Zheng,et al.  Fe-Au and Fe-Ag composites as candidates for biodegradable stent materials. , 2016, Journal of biomedical materials research. Part B, Applied biomaterials.

[38]  D. Zaffe,et al.  Accumulation of aluminium in lamellar bone after implantation of titanium plates, Ti-6Al-4V screws, hydroxyapatite granules. , 2004, Biomaterials.

[39]  P. Scolozzi,et al.  Complex orbito-fronto-temporal reconstruction using computer-designed PEEK implant. , 2007, The Journal of craniofacial surgery.

[40]  D. David Maxillofacial trauma: principles of management, priorities and basic techniques , 1999 .

[41]  Boeun Lee,et al.  Novel processing of iron-manganese alloy-based biomaterials by inkjet 3-D printing. , 2013, Acta biomaterialia.

[42]  Franco Persiani,et al.  CAD/CAM guided secondary mandibular reconstruction of a discontinuity defect after ablative cancer surgery. , 2012, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.