Noninvasive Analysis of Synthetic and Decellularized Scaffolds for Heart Valve Tissue Engineering

Microcomputed tomography (µ-CT) is a nondestructive, high-resolution, three-dimensional method of analyzing objects. The aim of this study was to evaluate the feasibility of using µ-CT as a noninvasive method of evaluation for tissue-engineering applications. The polyurethane aortic heart valve scaffold was produced using a spraying technique. Cryopreserved/thawed homograft and biological heart valve were decellularized using a detergent mixture. Human endothelial cells and fibroblasts were derived from saphenous vein segments and were verified by immunocytochemistry. Heart valves were initially seeded with fibroblasts followed by colonization with endothelial cells. Scaffolds were scanned by a µ-CT scanner before and after decellularization as well as after cell seeding. Successful colonization was additionally determined by scanning electron microscopy (SEM) and immunohistochemistry (IHC). Microcomputed tomography accurately visualized the complex geometry of heart valves. Moreover, an increase in the total volume and wall thickness as well as a decrease in total surface was demonstrated after seeding. A confluent cell distribution on the heart valves after seeding was confirmed by SEM and IHC. We conclude that µ-CT is a new promising noninvasive method for qualitative and quantitative analysis of tissue-engineering processes.

[1]  Timothy M Wright,et al.  Image-guided tissue engineering of anatomically shaped implants via MRI and micro-CT using injection molding. , 2008, Tissue engineering. Part A.

[2]  K Engelke,et al.  [Micro-CT. Technology and application for assessing bone structure]. , 1999, Der Radiologe.

[3]  K. Black,et al.  Decellularized human valve allografts. , 2001, The Annals of thoracic surgery.

[4]  J. Cremer,et al.  Durability of bioprosthetic cardiac valves. , 2008, Deutsches Arzteblatt international.

[5]  Artur Lichtenberg,et al.  In vitro re-endothelialization of detergent decellularized heart valves under simulated physiological dynamic conditions. , 2006, Biomaterials.

[6]  J. Birkmeyer,et al.  Do hospitals with low mortality rates in coronary artery bypass also perform well in valve replacement? , 2003, The Annals of thoracic surgery.

[7]  T C Flanagan,et al.  Living artificial heart valve alternatives: a review. , 2003, European cells & materials.

[8]  D. Ross,et al.  Aortic Root Replacement - 20 Years Experience of the Use of Homografts , 1991, The Thoracic and cardiovascular surgeon.

[9]  D. Cooley,et al.  Early degeneration of porcine xenograft valves in pediatric patients who have undergone apico-aortic bypass. , 1982, Texas Heart Institute journal.

[10]  M. Stuber,et al.  Magnetic Resonance Imaging Overestimates Ferumoxide-Labeled Stem Cell Survival After Transplantation in the Heart , 2008, Circulation.

[11]  E. Ritman,et al.  Relating Function to Branching Geometry: A Micro-CT Study of the Hepatic Artery, Portal Vein, and Biliary Tree , 2011, Cells Tissues Organs.

[12]  S. Rahimtoola,et al.  Choice of prosthetic heart valve for adult patients. , 2003, Journal of the American College of Cardiology.

[13]  David N Firmin,et al.  Magnetic resonance imaging of ferumoxide-labeled mesenchymal stem cells seeded on collagen scaffolds-relevance to tissue engineering. , 2006, Tissue engineering.

[14]  Gabriel P. Krestin,et al.  High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary Angiography , 2005, Circulation.

[15]  H. Kleinman,et al.  Role of laminin and basement membrane in the morphological differentiation of human endothelial cells into capillary-like structures , 1988, The Journal of cell biology.

[16]  Michael S Sacks,et al.  Bioengineering challenges for heart valve tissue engineering. , 2009, Annual review of biomedical engineering.

[17]  D J Wheatley,et al.  New polyurethane heart valve prosthesis: design, manufacture and evaluation. , 1996, Biomaterials.

[18]  F. Straka,et al.  Tissue-engineered heart valves. , 2009, Physiological research.

[19]  Aaron Fenster,et al.  Three-dimensional high-frequency ultrasound imaging for longitudinal evaluation of liver metastases in preclinical models. , 2005, Cancer research.

[20]  Erik L Ritman,et al.  Current status of developments and applications of micro-CT. , 2011, Annual review of biomedical engineering.

[21]  D. Holdsworth,et al.  Micro-CT in small animal and specimen imaging , 2002 .

[22]  Simon P Hoerstrup,et al.  Tissue engineering of heart valves using decellularized xenogeneic or polymeric starter matrices , 2007, Philosophical Transactions of the Royal Society B: Biological Sciences.

[23]  T. Krieg,et al.  Regulation of collagen synthesis in fibroblasts within a three-dimensional collagen gel. , 1988, Experimental cell research.

[24]  C. Funk,et al.  Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology , 2011, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[25]  I Naert,et al.  Individualised, micro CT-based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone. , 2004, Biomaterials.

[26]  R. R. Andrade,et al.  Oral anticoagulation in carriers of mechanical heart valve prostheses: experience of ten years. , 2010, Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular.

[27]  M. P. Morigi,et al.  Application of X-ray Computed Tomography to Cultural Heritage diagnostics , 2010 .

[28]  R. Prager,et al.  The aortic homograft: evolution of indications, techniques, and results in 107 patients. , 1997, The Annals of thoracic surgery.

[29]  Y. Liu,et al.  Application of stem cells for cardiovascular grafts tissue engineering. , 2006, Transplant immunology.

[30]  J. Fisher,et al.  Tissue engineering of cardiac valves: re-seeding of acellular porcine aortic valve matrices with human mesenchymal progenitor cells. , 2005, The Journal of heart valve disease.

[31]  W. Kalender X-ray computed tomography , 2006, Physics in medicine and biology.