Simulation modelling and analysis of modular cascaded multilevel converter based shunt hybrid active power filter for large scale photovoltaic system interconnection

Abstract Modular multilevel inverters are promising candidates for next generation of efficient, robust and reliable inverters in large scale photovoltaic system. A modular cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) for three phase grid-connected large scale PV systems is represented in this paper. The main contribution of this paper is to model and control of grid interfaced large scale photovoltaic system with embedded hybrid active power filter functions. In proposed system, the features of hybrid active power filter have been amalgamated in the control circuit of the voltage controlled voltage source inverter interfacing the photovoltaic system to the grid. As a result, the same inverter part of SHAPF is utilized to inject power generated from photovoltaic source to the grid and also to act as hybrid active power filter to compensate harmonics and reactive power demand. With using compensation ability, the grid currents are sinusoidal and in phase with grid voltages. The whole system is modeled in PSCAD/EMTDC. The simulation results are demonstrated to verify the operation and the control system of the proposed system.

[1]  Chun-Liang Liu,et al.  A comparative study on MPPT for photovoltaic generation systems , 2015, 2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC).

[2]  Kostas Kalaitzakis,et al.  Development of a microcontroller-based, photovoltaic maximum power point tracking control system , 2001 .

[3]  M. Vitelli,et al.  Optimization of perturb and observe maximum power point tracking method , 2005, IEEE Transactions on Power Electronics.

[4]  Igor Papic,et al.  A Proportional-Resonant Current Controller for Selective Harmonic Compensation in a Hybrid Active Power Filter , 2014, IEEE Transactions on Power Delivery.

[5]  P. Thirumoorthi,et al.  Design of current source hybrid power filter for harmonic current compensation , 2015, Simul. Model. Pract. Theory.

[6]  Keiji Wada,et al.  Design and Performance of a Transformerless Shunt Hybrid Filter Integrated Into a Three-Phase Diode Rectifier , 2007, IEEE Transactions on Power Electronics.

[7]  Chi-Seng Lam,et al.  Design and Performance of an Adaptive Low-DC-Voltage-Controlled LC-Hybrid Active Power Filter With a Neutral Inductor in Three-Phase Four-Wire Power Systems , 2014, IEEE Transactions on Industrial Electronics.

[8]  Mehmet Tümay,et al.  A New Control Approach for Shunt Hybrid Active Power Filter to Compensate Harmonics and Dynamic Reactive Power with Grid Interconnection , 2015, 2015 IEEE European Modelling Symposium (EMS).

[9]  Chi-Seng Lam,et al.  Hysteresis current control of hybrid active power filters , 2012 .

[10]  Zhao Wei,et al.  A new hybrid active power filter for harmonic suppression and reactive power compensation , 2008, 2008 China International Conference on Electricity Distribution.

[11]  Carlos A. Canesin,et al.  Comparative analysis of MPPT techniques for PV applications , 2011, 2011 International Conference on Clean Electrical Power (ICCEP).

[12]  An Luo,et al.  Design and application of a hybrid active power filter with injection circuit , 2010 .

[13]  Chi-Seng Lam,et al.  Minimum inverter capacity design for LC-hybrid active power filters in three-phase four-wire distribution systems , 2012 .

[14]  Hirofumi Akagi,et al.  A hybrid active filter for damping of harmonic resonance in industrial power systems , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[15]  Chi-Seng Lam,et al.  Analysis of DC-Link Voltage Controls in Three-Phase Four-Wire Hybrid Active Power Filters , 2013, IEEE Transactions on Power Electronics.

[16]  Avik Bhattacharya,et al.  Parallel-Connected Shunt Hybrid Active Power Filters Operating at Different Switching Frequencies for Improved Performance , 2012, IEEE Transactions on Industrial Electronics.

[17]  Mustafa Inci,et al.  Review of hybrid active power filter topologies and controllers , 2013, 4th International Conference on Power Engineering, Energy and Electrical Drives.

[18]  H. Akagi,et al.  A Hybrid Active Filter for a Three-Phase 12-Pulse Diode Rectifier Used as the Front End of a Medium-Voltage Motor Drive , 2012, IEEE Transactions on Power Electronics.

[19]  Hirofumi Akagi,et al.  A hybrid active filter for damping of harmonic resonance in industrial power systems , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[20]  Nadjwa Chettibi,et al.  FPGA-based real time simulation and control of grid-connected photovoltaic systems , 2014, Simul. Model. Pract. Theory.

[21]  Hirofumi Akagi,et al.  Active Harmonic Filters , 2005, Proceedings of the IEEE.

[22]  Mehmet Tumay,et al.  Modeling and Analysis of a Multilevel Parallel Hybrid Active Power Filter , 2016 .

[23]  Chi-Seng Lam,et al.  Adaptive DC-Link Voltage-Controlled Hybrid Active Power Filters for Reactive Power Compensation , 2012, IEEE Transactions on Power Electronics.

[24]  Syafaruddin,et al.  Modeling and simulation of photovoltaic (PV) system during partial shading based on a two-diode model , 2011, Simul. Model. Pract. Theory.

[25]  Hui Li,et al.  Decoupled Active and Reactive Power Control for Large-Scale Grid-Connected Photovoltaic Systems Using Cascaded Modular Multilevel Converters , 2015, IEEE Transactions on Power Electronics.

[26]  Hirofumi Akagi,et al.  A medium-voltage transformerless AC/DC power conversion system consisting of a diode rectifier and a shunt hybrid filter , 2002 .

[27]  Carlos Andrés Ramos-Paja,et al.  Reconfiguration analysis of photovoltaic arrays based on parameters estimation , 2013, Simul. Model. Pract. Theory.

[28]  Fujun Ma,et al.  System control of hybrid active power filter for reactive power compensation and harmonic suppression , 2011, 2011 6th IEEE Conference on Industrial Electronics and Applications.

[29]  Fabrice Locment,et al.  Maximum power tracking for photovoltaic power system: Development and experimental comparison of two algorithms , 2010 .

[30]  An Luo,et al.  Generalised design method for improving control quality of hybrid active power filter with injection circuit , 2014 .

[31]  Mohammad Reza Karami Mollaei,et al.  A predictive current control method for shunt active filter with windowing based wavelet transform in harmonic detection , 2009, Simul. Model. Pract. Theory.

[32]  J. Turunen,et al.  Comparison of three series hybrid active power filter topologies , 2004, 2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951).

[33]  H. Akagi,et al.  A 6.6-kV Transformerless Motor Drive Using a Five-Level Diode-Clamped PWM Inverter for Energy Savings of Pumps and Blowers , 2009, IEEE Transactions on Power Electronics.

[34]  Leon M. Tolbert,et al.  Efficiency improved and current balanced three-phase modular cascaded H-bridge multilevel PV inverter for grid-connected applications , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).