Statistical image quantification toward optimal scan fusion and change quantification

Recent advance of imaging technology has brought new challenges and opportunities for automatic and quantitative analysis of medical images. With broader accessibility of more imaging modalities for more patients, fusion of modalities/scans from one time point and longitudinal analysis of changes across time points have become the two most critical differentiators to support more informed, more reliable and more reproducible diagnosis and therapy decisions. Unfortunately, scan fusion and longitudinal analysis are both inherently plagued with increased levels of statistical errors. A lack of comprehensive analysis by imaging scientists and a lack of full awareness by physicians pose potential risks in clinical practice. In this paper, we discuss several key error factors affecting imaging quantification, studying their interactions, and introducing a simulation strategy to establish general error bounds for change quantification across time. We quantitatively show that image resolution, voxel anisotropy, lesion size, eccentricity, and orientation are all contributing factors to quantification error; and there is an intricate relationship between voxel anisotropy and lesion shape in affecting quantification error. Specifically, when two or more scans are to be fused at feature level, optimal linear fusion analysis reveals that scans with voxel anisotropy aligned with lesion elongation should receive a higher weight than other scans. As a result of such optimal linear fusion, we will achieve a lower variance than naïve averaging. Simulated experiments are used to validate theoretical predictions. Future work based on the proposed simulation methods may lead to general guidelines and error lower bounds for quantitative image analysis and change detection.

[1]  E. Van Cutsem,et al.  Size quantification of liver metastases in patients undergoing cancer treatment: reproducibility of one-, two-, and three-dimensional measurements determined with spiral CT. , 1997, Radiology.

[2]  Binsheng Zhao,et al.  Pulmonary metastases: effect of CT section thickness on measurement--initial experience. , 2005, Radiology.

[3]  Vincent Frouin,et al.  Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  David E. Breen,et al.  Level set segmentation from multiple non-uniform volume datasets , 2002, IEEE Visualization, 2002. VIS 2002..

[5]  Robert Tibshirani,et al.  An Introduction to the Bootstrap , 1994 .

[6]  K. Bae,et al.  Automated detection of pulmonary nodules on CT images: effect of section thickness and reconstruction interval--initial results. , 2005, Radiology.

[7]  Anthony P. Reeves,et al.  Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images , 2003, IEEE Transactions on Medical Imaging.

[8]  Antoni B. Chan,et al.  On measuring the change in size of pulmonary nodules , 2006, IEEE Transactions on Medical Imaging.

[9]  X. R. Li,et al.  Unified Optimal Linear Estimation Fusion — Part I : Unified Models and Fusion Rules , 2000 .

[10]  L. Schumm,et al.  Tumor size on computed tomography scans , 2001, Cancer.

[11]  Heinz-Otto Peitgen,et al.  Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans , 2006, IEEE Transactions on Medical Imaging.

[12]  Margrit Betke,et al.  Small pulmonary nodules: volume measurement at chest CT--phantom study. , 2003, Radiology.

[13]  Hideki Yoshikawa,et al.  Limits on the accuracy of 3-D thickness measurement in magnetic resonance images-effects of voxel anisotropy , 2003, IEEE Transactions on Medical Imaging.

[14]  Kevin J. Parker,et al.  MRI isotropic resolution reconstruction from two orthogonal scans , 2001, SPIE Medical Imaging.

[15]  A. Aisen,et al.  Effect of varying CT section width on volumetric measurement of lung tumors and application of compensatory equations. , 2003, Radiology.

[16]  Andrew Zisserman,et al.  Estimation of the partial volume effect in MRI , 2002, Medical Image Anal..