Thigh pain after cementless hip arthroplasty. Annoyance or ill omen.

A retrospective review of 148 consecutive porous-coated hip arthroplasties (PCA) showed an incidence of thigh pain of 13% one year after surgery, and 22% at two years. Positive correlations were made with femoral stem subsidence (greater than 2 mm) and with distal periosteal and endosteal bone formation. No positive correlations were made with parameters of bone quality or component fit. Resolution of pain occurred in one-third and an anti-inflammatory agent produced partial relief in two-thirds of the patients. We conclude that thigh pain is secondary to stem instability with distal stress transfer in the absence of stable proximal fixation.

[1]  R. N. Stauffer,et al.  Cemented total hip arthroplasty with contemporary techniques. A five-year minimum follow-up study. , 1988, Clinical orthopaedics and related research.

[2]  J. Galante,et al.  Sintered fiber metal composites as a basis for attachment of implants to bone. , 1971, The Journal of bone and joint surgery. American volume.

[3]  I. Clarke,et al.  Porous ingrowth fixation of the femoral component in a canine surface replacement of the hip. , 1982, Clinical orthopaedics and related research.

[4]  D. Hungerford,et al.  Two-year follow-up of the PCA noncemented total hip replacement. , 1987, The Hip.

[5]  R M Pilliar,et al.  The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. , 1980, Clinical orthopaedics and related research.

[6]  K. Hardinge The direct lateral approach to the hip. , 1982, The Journal of bone and joint surgery. British volume.

[7]  T. Andrew,et al.  The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases. , 1986, Clinical orthopaedics and related research.

[8]  W. Harris,et al.  Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up. , 1986, The Journal of bone and joint surgery. American volume.

[9]  W. Harris,et al.  Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape. , 1984, Clinical orthopaedics and related research.

[10]  C. Engh,et al.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. , 1987, The Journal of bone and joint surgery. British volume.

[11]  G. Lord,et al.  The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study. , 1983, Clinical orthopaedics and related research.

[12]  Ring Pa,et al.  Ring UPM total hip arthroplasty. , 1983 .

[13]  I Macnab,et al.  Porous surface layered prosthetic devices. , 1975, Biomedical engineering.

[14]  C. Engh Recent advances in cementless total hip arthroplasty using the AML prosthesis , 1991 .

[15]  R. Stauffer 10-year follow-up study of total hip replacement: with particular reference to roentgenographic loosening of the components. , 1982 .

[16]  J J Callaghan,et al.  The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. , 1988, The Journal of bone and joint surgery. American volume.