High-speed miniaturized swept sources based on resonant MEMS mirrors and diffraction gratings

We show a broad range of swept source performances based on a highly-flexible external cavity laser architecture. Specifically, we demonstrate a 40-kHz 1300-nm swept source with 10 mm coherence length realized in a compact butterfly package. Fast wavelength sweeping is achieved through a 1D 20-kHz MEMS mirror in combination with an advanced diffraction grating. The MEMS mirror is a resonant electrostatic mirror that performs harmonic oscillation only within a narrow frequency range, resulting in low-jitter and long-term phase-stable sinusoidal bidirectional sweep operation with an A-scan rate of 40 kHz. The source achieves a coherence length of 10 mm for both the up- and downsweep and an OCT sensitivity of 105 dB.

[1]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[2]  S. Yun,et al.  High-speed optical frequency-domain imaging. , 2003, Optics express.

[3]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[4]  J. Fujimoto,et al.  Optical coherence tomography using a frequency-tunable optical source. , 1997, Optics letters.

[5]  V. Jayaraman,et al.  Design and performance of broadly tunable , narrow linewidth , high repetition rate 1310 nm VCSELs for swept source optical coherence tomography , 2012 .

[6]  Brett E Bouma,et al.  Miniature swept source for point of care optical frequency domain imaging. , 2009, Optics express.

[7]  T. von Niederhäusern,et al.  FPGA-based non-uniform fast Fourier transform (NUFFT) algorithm for real-time OCT signal processing , 2013, Photonics West - Biomedical Optics.

[8]  James G. Fujimoto,et al.  Design and performance of broadly tunable, narrow line-width, high repetition rate 1310nm VCSELs for swept source optical coherence tomography , 2012, Photonics West - Optoelectronic Materials and Devices.

[9]  Josef Goette,et al.  FPGA-based real-time swept-source OCT systems for B-scan live-streaming or volumetric imaging , 2013, Photonics West - Biomedical Optics.

[10]  W. Marsden I and J , 2012 .

[11]  J. Duker,et al.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second. , 2010, Optics express.

[12]  Christoph Meier,et al.  Instantaneous coherence length measurement of a swept laser source using a Mach-Zehnder interferometer , 2011, BiOS.

[13]  Dennis Derickson,et al.  High-speed concatenation of frequency ramps using sampled grating distributed Bragg reflector laser diode sources for OCT resolution enhancement , 2010, BiOS.

[14]  J. Fujimoto,et al.  High speed engine gas thermometry by Fourier-domain mode-locked laser absorption spectroscopy. , 2007, Optics express.