A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loading

The hysteretic behaviour of RC columns has been object of many experimental studies over the past years. However, the majority of these studies are focused on unidirectional loading. An experimental program was carried out where 24 columns were tested for different loading histories, under uniaxial and biaxial conditions. The experimental results are presented in this paper and are discussed in terms of global column behaviour, and particularly with regards to energy dissipation and damping capacity. The energy dissipation capacity of the columns was evaluated in terms of cumulative dissipated energy, comparing uniaxial and biaxial test results, and individual cycle dissipated energy. Ultimately, an equation relating the normalised dissipated energy with the displacement ductility is proposed. The equivalent viscous damping was analysed by comparing the uniaxial with biaxial test results, demonstrating the high influence of the load path in the biaxial response of RC columns. Proposals for estimating the equivalent viscous damping given by other authors are compared with the experimental results. Finally, simplified expressions are proposed to estimate equivalent viscous damping in RC columns under biaxial loading.

[1]  Gian Michele,et al.  Direct Displacement-Based Seismic Design of Structures , 2007 .

[2]  Tae-Sung Eom,et al.  Evaluation of energy dissipation of slender reinforced concrete members and its applications , 2010 .

[3]  Thomas G. Brown,et al.  Hysteretic energy and damping capacity of flexural elements constructed with different concrete strengths , 2010 .

[4]  H Rodrigues,et al.  Experimental study on the biaxial bending cyclic behaviour of RC columns , 2010 .

[5]  David Darwin,et al.  Cyclic Behavior of Lightly Reinforced Concrete Beams , 1984 .

[6]  Ismael Herrera,et al.  On a Kind of Hysteretic Damping , 1964 .

[7]  M. Sozen,et al.  Inelastic Responses of Reinforced ConcreteStructure to Earthquake Motions , 1974 .

[8]  Pedro F. Silva,et al.  Estimating equivalent viscous damping ratio for RC members under seismic and blast loadings , 2006 .

[9]  Peng Pan,et al.  Experimental tests on reinforced concrete columns under biaxial quasi-static loading , 2002 .

[10]  A. Ang,et al.  Mechanistic Seismic Damage Model for Reinforced Concrete , 1985 .

[11]  F Qiu,et al.  EXPERIMENTAL TESTS ON RC COLUMNS UNDER BIAXIAL QUASI-STATIC LOADING , 2002 .

[12]  Amorim Varum Humberto Seismic Assessment, Strengthening and Repair of Existing Buildings , 2003 .

[13]  Michael N. Fardis,et al.  Load-Path Effects in Column Biaxial Bending with Axial Force , 1995 .

[14]  Akinori Nakajima,et al.  Cyclic shear force–slip behavior of studs under alternating and pulsating load condition , 2003 .

[15]  Mjn Priestley,et al.  Direct displacement-based seismic design , 2005 .

[16]  Mete A. Sozen,et al.  SUBSTITUTE-STRUCTURE METHOD FOR SEISMIC DESIGN IN R/C , 1976 .

[17]  Mervyn J. Kowalsky,et al.  Equivalent Damping in Support of Direct Displacement-Based Design , 2004 .

[18]  Takashi Nishioka,et al.  AN EXPERIMENTAL STUDY ON ENERGY ABSORPTION CAPACITY OF COLUMNS IN REINFORCED CONCRETE STRUCTURES , 1984 .

[19]  M. J. N. Priestley,et al.  EQUIVALENT VISCOUS DAMPING EQUATIONS FOR DIRECT DISPLACEMENT BASED DESIGN , 2005 .

[20]  Kazuhiro Tsuno,et al.  EXPERIMENTAL STUDY OF REINFORCED CONCRETE BRIDGE PIERS SUBJECTED TO BI-DIRECTIONAL QUASI-STATIC LOADING , 2004 .

[22]  D. Darwin,et al.  ENERGY DISSIPATION IN RC BEAMS UNDER CYCLIC LOAD , 1986 .

[23]  Hong Hao,et al.  Seismic performance of RC frames designed for three different ductility levels , 2001 .

[24]  M. Priestley DISPLACEMENT-BASED SEISMIC ASSESSMENT OF REINFORCED CONCRETE BUILDINGS , 1997 .