Comparison of simplified models for voltage-source-inverter-fed adjustable-speed drive during voltage sags when the during-event continue mode of operation is active

Three simplified models for adjustable-speed drives are compared with measurements on an actual drive where the inverter control strategy remains unaltered during the event (also known as continue mode of operation) to assess drive behaviour prediction during balanced and unbalanced sags. In particular, the models calculate the dc-link voltage and ac line current dynamic evolution, assuming that neither the drive nor the system protection will trip. The comparison reveals minor differences in behaviour between the three models and the actual drive, although the constant current model exhibits slightly a better agreement. To verify whether differences in the simplified models remain small, extensive ranges of sags are simulated, and drive sensitivity to sag type and depth is illustrated. As the straightforward models studied predict the measured drive dynamic behaviour in severe network conditions with similar accuracy to other unnecessarily complicated models, they are very useful to reduce computational burden and overall complexity for sag immunity as well as dynamic and steady-state network studies. On the other hand, laboratory measurements on the actual drive when the inertia ride-through mode of operation is active illustrate that the simplified models are not valid when the inverter control strategy is modified during the sag.

[1]  Wilsun Xu,et al.  Modelling of adjustable speed drives for power system harmonic analysis , 1999 .

[2]  Giovanni Maria Foglia,et al.  Comprehensive steady-state analytical model of a three-phase diode rectifier connected to a constant DC voltage source , 2013 .

[3]  Hans-Peter Nee,et al.  DC-Link Stabilization and Voltage Sag Ride-Through of Inverter Drives , 2006, IEEE Transactions on Industrial Electronics.

[4]  M. H. J. Bollen Voltage Recovery after Unbalanced and Balanced Voltage Dip in Three-Phase Systems , 2002, IEEE Power Engineering Review.

[5]  T.M. Jahns,et al.  Source current harmonic analysis of adjustable speed drives under input voltage unbalance and sag conditions , 2004, IEEE Transactions on Power Delivery.

[6]  J. Svensson,et al.  Voltage tolerance testing of three-phase voltage source converters , 2005, IEEE Transactions on Power Delivery.

[7]  L. Sainz,et al.  Symmetrical and unsymmetrical voltage sag effects on three-phase transformers , 2005, IEEE Transactions on Power Delivery.

[8]  Pierre Angers,et al.  Voltage dip immunity of PWM drives with ride-through capabilities , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[9]  T.A. Lipo,et al.  Closed-form analysis of adjustable-speed drive performance under input-voltage unbalance and sag conditions , 2006, IEEE Transactions on Industry Applications.

[10]  Vojkan Kostic,et al.  Comparative study of unsymmetrical voltage sag effects on adjustable speed induction motor drives , 2011 .

[11]  Jovica V. Milanovic,et al.  Modelling of V–Hz and vector controlled ASDs in PSCAD/EMTDC for voltage sag studies , 2010 .

[12]  J. Pedra,et al.  Effects of balanced and unbalanced voltage sags on VSI-fed adjustable-speed drives , 2005, IEEE Transactions on Power Delivery.

[13]  R. Spee,et al.  Voltage sag ride-through for adjustable speed drives with active rectifiers , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.