An Innovative fuzzy based Power Quality Assessment of Distorted Electrical Power System

Electrical power quality evaluation is highly importantas penetration of renewable energy into the grid and uses of non linear load are drastically increasing in the modern era. There are different power quality indices which evaluates the power quality but it is highly essential to combine all the indices into a single value which can evaluates the power quality effectively. The innovative power quality index is found out considering the following component such as representative quality factor(RQPF), detailed pollution factor(DPF),total harmonic distortion(THD) and short circuit level(SCL).Fuzzy inference system has been implemented for doing the amalgamation of different power quality indices. In this paper THD module is formed by the amalgamation of total harmonic distortion voltage(THDV) and total harmonic distortion current(THDI) and THDSCL module is formed by the fusion of THD and SCL. The innovative power quality is formed by the mixture of THDSCL,DP and RQPF which has better significance both in quality and quantity point of view.

[1]  M. El-Hawary,et al.  Reformulating Power Components Definitions Contained in the IEEE Standard 1459–2000 Using Discrete Wavelet Transform , 2007, IEEE Transactions on Power Delivery.

[2]  Walid G. Morsi,et al.  Power quality evaluation in smart grids considering modern distortion in electric power systems , 2011 .

[3]  karthik nooney Classification of Power quality problems by wavelet Fuzzy expert system , 2011 .

[4]  Walid G. Morsi,et al.  Fuzzy-Wavelet-Based Electric Power Quality Assessment of Distribution Systems Under Stationary and Nonstationary Disturbances , 2009 .

[5]  Sudipta Debnath,et al.  Harmonic source identification in distribution system using non-active power quantities , 2017 .

[6]  M. El-Hawary,et al.  Reformulating Three-Phase Power Components Definitions Contained in the IEEE Standard 1459–2000 Using Discrete Wavelet Transform , 2007, IEEE Transactions on Power Delivery.

[7]  A. Cataliotti,et al.  A single-point approach based on IEEE 1459-2000 for the identification of detection of prevailing harmonic sources in distorted three phase power systems , 2009 .

[8]  Walid Morsi,et al.  Fuzzy-Wavelet-Based Electric Power Quality Assessment of Distribution Systems Under Stationary and Nonstationary Disturbances , 2009, IEEE Transactions on Power Delivery.

[9]  M.E. El-Hawary,et al.  Wavelet Packet Transform-Based Power Quality Indices for Balanced and Unbalanced Three-Phase Systems Under Stationary or Nonstationary Operating Conditions , 2009, IEEE Transactions on Power Delivery.