Metrological characterization of a combined bio-impedance plethysmograph and spectrometer
暂无分享,去创建一个
Stefano Pisa | Emanuele Piuzzi | Emanuele Rizzuto | Zaccaria Del Prete | Erika Pittella | Z. Prete | E. Pittella | S. Pisa | E. Piuzzi | E. Rizzuto
[1] Hsiao-Lung Chan,et al. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition , 2015, Sensors.
[2] James J. Ackmann,et al. Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHz , 1993, Annals of Biomedical Engineering.
[3] D. Altman,et al. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.
[4] Gerd Vandersteen,et al. Optimal multisine excitation design for broadband electrical impedance spectroscopy , 2011 .
[5] S A Grover,et al. A randomized management study of impedance plethysmography vs. contrast venography in patients with a first episode of clinically suspected deep vein thrombosis. , 2001, Thrombosis research.
[6] E. Irzmańska,et al. Impedance plethysmography as a tool for assessing exertion-related blood flow changes in the lower limbs in healthy subjects , 2014 .
[7] M Gent,et al. Diagnosis of Venous Thrombosis , 2005 .
[8] W. Gulliver,et al. Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population. , 2005, The American journal of clinical nutrition.
[9] M. Elia,et al. Bioelectrical impedance analysis-part II: utilization in clinical practice. , 2004, Clinical nutrition.
[10] Joseph D. Bronzino,et al. The Biomedical Engineering Handbook , 1995 .
[11] Ahmad Keshtkar,et al. Virtual bladder biopsy using bio-impedance spectroscopy at 62.500 Hz–1.024 MHz , 2007 .
[12] P T Toy,et al. Occlusive impedance plethysmography. A noninvasive method of diagnosis of proximal deep vein thrombosis. , 1978, The Western journal of medicine.
[13] J. Rosell,et al. Signal-to-motion artifact ratio versus frequency for impedance pneumography , 1995, IEEE Transactions on Biomedical Engineering.
[14] P E Ward,et al. Impedance plethysmography. A screening procedure to detect deep-vein thrombosis. , 1987, The Journal of bone and joint surgery. British volume.
[15] K. Cole,et al. Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics , 1941 .
[16] M. Elia,et al. Bioelectrical impedance analysis--part I: review of principles and methods. , 2004, Clinical nutrition.
[17] Alessandro Magnani,et al. Wearable Multi-Frequency and Multi-Segment Bioelectrical Impedance Spectroscopy for Unobtrusively Tracking Body Fluid Shifts during Physical Activity in Real-Field Applications: A Preliminary Study , 2016, Sensors.
[18] J. Rosell,et al. Reduction of motion artifacts using a two-frequency impedance plethysmograph and adaptive filtering , 1995, IEEE Transactions on Biomedical Engineering.
[19] J. Nyboer,et al. Electrical Impedance Plethysmography: A Physical and Physiologic Approach to Peripheral Vascular Study , 1950, Circulation.
[20] Rosalind J. Sadleir,et al. Biocompatible, High Precision, Wideband, Improved Howland Current Source With Lead-Lag Compensation , 2013, IEEE Transactions on Biomedical Circuits and Systems.
[21] C. Earthman,et al. Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgery. , 2008, Clinical nutrition.
[22] G. Chertow,et al. Multifrequency bioelectrical impedance estimates the distribution of body water. , 1995, Journal of applied physiology.
[23] Fatimah Ibrahim,et al. The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases , 2014, Sensors.