Analysis of the Accuracy and Robustness of the Leap Motion Controller

The Leap Motion Controller is a new device for hand gesture controlled user interfaces with declared sub-millimeter accuracy. However, up to this point its capabilities in real environments have not been analyzed. Therefore, this paper presents a first study of a Leap Motion Controller. The main focus of attention is on the evaluation of the accuracy and repeatability. For an appropriate evaluation, a novel experimental setup was developed making use of an industrial robot with a reference pen allowing a position accuracy of 0.2 mm. Thereby, a deviation between a desired 3D position and the average measured positions below 0.2 mm has been obtained for static setups and of 1.2 mm for dynamic setups. Using the conclusion of this analysis can improve the development of applications for the Leap Motion controller in the field of Human-Computer Interaction.

[1]  J. Langston,et al.  Voluntarily simulated tremor in normal subjects , 2002, Neurophysiologie Clinique/Clinical Neurophysiology.

[2]  Tapani Koivukangas,et al.  Technical accuracy of optical and the electromagnetic tracking systems , 2013, SpringerPlus.

[3]  Achim J. Lilienthal,et al.  Comparative Evaluation of Range Sensor Accuracy in Indoor Environments , 2011, ECMR.

[4]  P. Fitts The information capacity of the human motor system in controlling the amplitude of movement. , 1954, Journal of experimental psychology.

[5]  Bernd Jähne,et al.  A theoretical and experimental investigation of the systematic errors and statistical uncertainties of Time-Of-Flight-cameras , 2008, Int. J. Intell. Syst. Technol. Appl..

[6]  David E Vaillancourt,et al.  Effects of aging on the regularity of physiological tremor. , 2005, Journal of neurophysiology.

[7]  Devin R. Berg,et al.  Precision, repeatability and accuracy of Optotrak® optical motion tracking systems , 2009 .

[8]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[9]  Roger Y. Tsai,et al.  A new technique for fully autonomous and efficient 3D robotics hand/eye calibration , 1988, IEEE Trans. Robotics Autom..

[10]  Reinhard Koch,et al.  Time-of-Flight Sensors in Computer Graphics , 2009, Eurographics.

[11]  Filiberto Chiabrando,et al.  Sensors for 3D Imaging: Metric Evaluation and Calibration of a CCD/CMOS Time-of-Flight Camera , 2009, Sensors.

[12]  Shimon Y. Nof,et al.  Handbook of Industrial Robotics , 2013 .

[13]  Kanad K. Biswas,et al.  Gesture recognition using Microsoft Kinect® , 2011, The 5th International Conference on Automation, Robotics and Applications.

[14]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[15]  Reinhard Koch,et al.  Time-of-Flight sensor calibration for accurate range sensing , 2010, Comput. Vis. Image Underst..

[16]  Roland Siegwart,et al.  A state-of-the-art 3D sensor for robot navigation , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[17]  Nathan Silberman,et al.  Indoor scene segmentation using a structured light sensor , 2011, 2011 IEEE International Conference on Computer Vision Workshops (ICCV Workshops).

[18]  Eugene Ch'ng New Ways of Accessing Information Spaces Using 3D Multitouch Tables , 2012, 2012 International Conference on Cyberworlds.

[19]  Mumin Song,et al.  Overview of three-dimensional shape measurement using optical methods , 2000 .

[20]  Kristian Ambrosch,et al.  Accurate hardware-based stereo vision , 2010, Comput. Vis. Image Underst..

[21]  Sander Oude Elberink,et al.  Accuracy and Resolution of Kinect Depth Data for Indoor Mapping Applications , 2012, Sensors.

[22]  M. Braga,et al.  Exploratory Data Analysis , 2018, Encyclopedia of Social Network Analysis and Mining. 2nd Ed..

[23]  P Munger,et al.  Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery. , 1995, Journal of image guided surgery.

[24]  Gerd Bruder,et al.  Effects of visual conflicts on 3D selection task performance in stereoscopic display environments , 2013, 2013 IEEE Symposium on 3D User Interfaces (3DUI).

[25]  Toshiyuki Takatsuji,et al.  What is Metrology , 2015 .