Micro-scale Geometry Measurement
暂无分享,去创建一个
[1] Ning Zhang,et al. Tiny endoscopic optical coherence tomography probe driven by a miniaturized hollow ultrasonic motor , 2013, Journal of biomedical optics.
[2] Jiang Hsieh,et al. Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .
[3] Qinping Zhao,et al. Fringe projection based quantitative 3D microscopy , 2013 .
[4] J. I. McCool,et al. Assessing the Effect of Stylus Tip Radius and Flight on Surface Topography Measurements , 1984 .
[5] Gaoliang Dai,et al. A high precision micro/nano CMM using piezoresistive tactile probes , 2009 .
[6] G. Wnek,et al. Encyclopedia of biomaterials and biomedical engineering , 2008 .
[7] Francois Blais,et al. Lateral resolution challenges for triangulation-based three-dimensional imaging systems , 2012 .
[8] H. Donald Gage,et al. Statistical models of partial volume effect , 1995, IEEE Trans. Image Process..
[9] Woonggyu Jung,et al. Optical sectioning for microfluidics: secondary flow and mixing in a meandering microchannel. , 2008, Lab on a chip.
[10] Kenneth T. V. Grattan,et al. Laser-based triangulation techniques in optical inspection of industrial structures , 1991, Optics & Photonics.
[11] Wolfgang Osten,et al. Solving the inverse grating problem by white light interference Fourier scatterometry , 2012, Light: Science & Applications.
[12] Feng Gao,et al. Surface measurement errors using commercial scanning white light interferometers , 2007 .
[13] P. Cloetens,et al. Sub-micrometer synchrotron tomography of multiphase metals using Kirkpatrick–Baez optics , 2009 .
[14] Meng Nie,et al. Static and Dynamic Deformation Measurements of Micro Beams by the Technique of Digital Image Correlation , 2006 .
[15] H Han Haitjema,et al. Development of a Silicon-based Nanoprobe System for 3-D Measurements , 2001 .
[16] J. Schmitt,et al. Speckle in optical coherence tomography. , 1999, Journal of biomedical optics.
[17] Chenggen Quan,et al. Microscopic surface contouring by fringe projection method , 2002 .
[18] R. Danzl,et al. Focus Variation – a Robust Technology for High Resolution Optical 3D Surface Metrology , 2011 .
[19] Fengzhou Fang,et al. Manufacturing and measurement of freeform optics , 2013 .
[20] R. Leach. Optical measurement of surface topography , 2011 .
[21] Robert Schmitt,et al. Industrial applications of computed tomography , 2014 .
[22] Peter J. de Groot,et al. Principles of interference microscopy for the measurement of surface topography , 2015 .
[23] Gianfranco Genta,et al. Measurement uncertainty assessment of Coordinate Measuring Machines by simulation and planned experimentation , 2011 .
[24] J Schwider,et al. Dispersive interferometric profilometer. , 1994, Optics letters.
[25] Michael Leitner,et al. Accurate and automated image segmentation of 3D optical coherence tomography data suffering from low signal-to-noise levels. , 2014, Journal of the Optical Society of America. A, Optics, image science, and vision.
[26] Richard J. Fitzgerald,et al. Phase‐Sensitive X‐Ray Imaging , 2000 .
[27] C. Hitzenberger,et al. Dynamic optical studies in materials testing with spectral-domain polarization-sensitive optical coherence tomography. , 2010, Optics express.
[28] S. Scherer,et al. Adaptive shape from focus with an error estimation in light microscopy , 2001, ISPA 2001. Proceedings of the 2nd International Symposium on Image and Signal Processing and Analysis. In conjunction with 23rd International Conference on Information Technology Interfaces (IEEE Cat..
[29] Jochen Hiller,et al. Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications , 2012 .
[30] Alan R. Hibbs,et al. Confocal Microscopy for Biologists , 2004, Springer US.
[31] V. Radhakrishnan,et al. Effect of stylus radius on the roughness values measured with tracing stylus instruments , 1970 .
[32] H. Schwenke,et al. Error mapping of CMMs and machine tools by a single tracking interferometer , 2005 .
[33] Bruce D. Smith. Cone-beam tomography: recent advances and a tutorial review , 1990 .
[34] K. Kawachi,et al. Two-directional scanning method for reducing the shadow effects in laser triangulation , 1997 .
[35] Risto Myllylä,et al. Characterization of ink-jet printed RGB color filters with spectral domain optical coherence tomography , 2012, Other Conferences.
[36] Sai Siva Gorthi,et al. Fringe projection techniques: Whither we are? , 2010 .
[37] Richard K. Leach,et al. Development of a three-dimensional vibrating tactile probe for miniature CMMs , 2013 .
[38] A. Weckenmann,et al. Multi-energy image stack fusion in computed tomography , 2010 .
[39] G. J. Brakenhoff,et al. Confocal scanning light microscopy with high aperture immersion lenses , 1979 .
[40] Wim Dewulf,et al. Towards geometrical calibration of x-ray computed tomography systems—a review , 2015 .
[41] J. Fujimoto,et al. Optical coherence tomography: technology and applications , 2002, IEEE/LEOS International Conference on Optical MEMs.
[42] Hans Nørgaard Hansen,et al. Replication and dimensional quality control of industrial nanoscale surfaces using calibrated AFM measurements and SEM image processing , 2010 .
[43] Ying Zhang,et al. A new focus measure method using moments , 2000, Image Vis. Comput..
[44] Robert Schmitt,et al. Geometric error measurement and compensation of machines : an update , 2008 .
[45] A. Weckenmann,et al. Probing Systems in Dimensional Metrology , 2004 .
[46] Phj Piet Schellekens,et al. Design of a High-Precision 3D-Coordinate Measuring Machine , 1998 .
[47] K. H. Kjaer,et al. 3D Laser Triangulation for Plant Phenotyping in Challenging Environments , 2015, Sensors.
[48] Wim Dewulf,et al. Uncertainty determination and quantification for dimensional measurements with industrial computed tomography , 2013 .
[49] David T. D. Childs,et al. Evaluation of selective laser sintering processes by optical coherence tomography , 2015 .
[50] James C. Wyant,et al. Large Field of View, High Spatial Resolution, Surface Measurements , 1998 .
[51] Adolf Friedrich Fercher,et al. Dispersion induced multiple signal peak splitting in partial coherence interferometry , 1998 .
[52] Takashi Miyoshi,et al. Development of The Nano-CMM Probe based on Laser Trapping Technology , 1999 .
[53] Ralph C. Veale,et al. Error Compensation of Coordinate Measuring Machines , 1985 .
[54] C. Boccara,et al. Ultrahigh-resolution full-field optical coherence tomography. , 2004, Applied optics.
[55] R. Brooks,et al. Beam hardening in X-ray reconstructive tomography , 1976 .
[56] Chang-Ock Lee,et al. An algorithm for stylus instruments to measure aspheric surfaces , 2005 .
[57] D. Stifter,et al. Beyond biomedicine: a review of alternative applications and developments for optical coherence tomography , 2007 .
[58] Liang-Chia Chen,et al. High Accuracy Confocal Full-Field 3-D Surface Profilometry for Micro Lenses Using a Digital Fringe Projection Strategy , 2007 .
[59] Tong Guo,et al. Microscopic fringe projection system and measuring method , 2013, Other Conferences.
[60] Chih-Liang Chu,et al. Development of a low-cost nanoscale touch trigger probe based on two commercial DVD pick-up heads , 2007 .
[61] Ernest W Chang,et al. Perspectives of mid-infrared optical coherence tomography for inspection and micrometrology of industrial ceramics. , 2014, Optics express.
[62] J A Rowlands,et al. X-ray detectors for digital radiography. , 1997, Physics in medicine and biology.
[63] H. A. M. Spaan,et al. Realization and calibration of the "Isara 400" ultra-precision CMM , 2011 .
[64] Robert Schmitt,et al. Computed tomography for dimensional metrology , 2011 .
[65] T. Wilson,et al. Resolution and optical sectioning in the confocal microscope , 2011, Journal of microscopy.
[66] V. Mendeleyev. Dependence of measuring errors of rms roughness on stylus tip size for mechanical profilers. , 1997, Applied optics.
[67] Peter J. de Groot,et al. Optical Topography Measurement of Patterned Wafers , 2005 .
[68] A. Diaspro. Confocal and two-photon microscopy : foundations, applications, and advances , 2001 .
[69] Eung-Suk Lee,et al. A Hole-Plate Artifact Design for the Volumetric Error Calibration of CMM , 2001 .
[70] Wolfgang Wieser,et al. Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second. , 2010, Optics express.
[71] M. Minsky. Memoir on inventing the confocal scanning microscope , 1988 .
[72] David J. Whitehouse,et al. Handbook of Surface and Nanometrology, Second Edition , 2011 .
[73] Theodore D. Doiron,et al. Dimensional metrology of bipolar fuel cell plates using laser spot triangulation probes , 2011 .
[74] Ming-Jun Lai,et al. Full-field micro surface profilometry using digital fringe projection with spatial encoding principle , 2005 .
[75] Franz Helmli,et al. Optical roughness measurements on specially designed roughness standards , 2008, Optical Systems Design.
[76] John M. Boone,et al. X-Ray Production, Interaction, and Detection in Diagnostic Imaging , 2000 .
[77] Meng Wang,et al. Fringe projection 3D microscopy with the general imaging model. , 2015, Optics express.
[78] Richard M. Seugling,et al. INVESTIGATING SCALING LIMITS OF A FIBER BASED RESONANT PROBE FOR METROLOGY APPLICATIONS , 2008 .
[79] Dong-Hyeok Lee. 3-Dimensional profile distortion measured by stylus type surface profilometer , 2013 .
[80] Matthias Goldammer,et al. Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CT , 2011 .
[81] Joseph C. Marron,et al. 3-D imaging using a tunable laser source , 2000 .
[82] O. Paul,et al. Novel 3D piezoresistive silicon force sensor for dimensional metrology of micro components , 2005, IEEE Sensors, 2005..
[83] F. Krebs,et al. Application of optical coherence tomography (OCT) as a 3-dimensional imaging technique for roll-to-roll coated polymer solar cells , 2012 .
[85] Ali Peiravi,et al. A Reliable 3D Laser Triangulation-based Scanner with a New Simple but Accurate Procedure for Finding Scanner Parameters , 2010 .
[86] X. Jiang,et al. Precision surface measurement , 2012, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.
[87] Jean-Pierre Kruth,et al. Compensation of Static and Transient Thermal Errors on CMMs , 2001 .
[88] Jim Kramer,et al. Determination of fringe order in white-light interference microscopy. , 2002, Applied optics.
[89] J. Hsieh,et al. A novel reconstruction algorithm to extend the CT scan field-of-view. , 2004, Medical physics.
[90] J H Siewerdsen,et al. An empirical method for lag correction in cone-beam CT. , 2008, Medical physics.
[91] H J Tiziani,et al. Microshape and rough-surface analysis by fringe projection. , 1994, Applied optics.
[92] Richard K. Leach,et al. A review of the existing performance verification infrastructure for micro-CMMs , 2015 .
[93] E. Landis,et al. X-ray microtomography , 2010 .
[94] R. Thalmann,et al. Ultraprecision micro-CMM using a low force 3D touch probe , 2007 .
[95] Li Jin,et al. Equal-channel angular pressing of magnesium alloy AZ91 and its effects on microstructure and mechanical properties , 2008 .